§ 13.16.030 — Definitions
Municipal Code of the City of Lawrence, Massachusetts (Codified through Document No. 132/2022, approved June 7, 2022 (Supp. No. 8; publisher-stale)) · Lawrence Municipal Code § 13.16.030
Corpus is an independent public-information project, not the official City of Lawrence website. Stable reference: corpuslaw.us/code/85557689-95ea-40a4-a310-32c4375c3380
13.16.030 - Definitions.
As used in this chapter: Air gap separation means the method of preventer backflow through the use of an unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet supplying water to a tank, plumbing fixture, or other device and the flood level rim of the receptacle. Approved means accepted by the reviewing authority meeting an applicable specification stated or cited into chapter or as suitable for the proposed use. Approved backflow prevention device or devices means a method to prevent backflow approved by the department for use in Massachusetts. Atmospheric vacuum breaker means an approved backflow device used to prevent back siphonage, which is not designed for use under static line pressure. Auxiliary water supply means any water supply of unknown or unquestionable quality on or available to the premises other than the supplier's approved public potable water supply. Back pressure means pressure created by mechanical means or other means, which causes water or other liquids or substances to flow or move in a direction opposite to that which is intended. Back siphonage means a form of backflow due to reduced or sub-atmospheric pressure within a water system. Backflow means the flow of water or other liquids, mixtures or substances into the distribution pipes of a potable water supply from any source other than the intended source. Backflow preventer with intermediate atmospheric vent means a device having two independently operating check valves separated by an intermediate chamber with a means for automatically venting it to the atmosphere, in which the check valves are force-loaded to a normally closed position and the venting means is force-loaded to a normally open position. Backflow tester means a certified tester by the state DEP, for backflow preventers. Barometric loop means a loop of pipe rising at last [least] 35 feet, at its topmost point above the highest fixture it supplies. Commissioner means the water commissioner of the City of Lawrence. Contaminant means any physical chemical, biological or radiological substance or matter in water. Coordinator means the cross connection control coordinator of the City of Lawrence. Cross connection means any actual or potential connection between a distribution pipe of potable water from a public water system and any waste pipe, soil pipe, sewer, drain, or other unapproved source. Cross connection forms means a form designated by the department, which is sent to the owner, by the water supplier with copies sent to the DEP, plumbing inspector and board of health, delineating cross connections found on the owner's premises and a procedure for corrective action. Cross connection inspector means a certified inspector by the state DEP, for cross connection. Cross connection program means the water suppliers describing the cross connection control program, including information on staffing, training, testing, surveying, fees structure etc. Department means the Massachusetts Department of Environmental Protection (DEP). Double check valve assembly means a backflow preventer device, which incorporates an assembly of check valves, with shut-off valves at each end and appurtenances for testing. In-plant protection means the location of approved backflow prevention devices in a manner that provides simultaneous protection of the public water system and the potable water system within the premises. Owner means any person maintaining a cross connection installation or owning or occupying premises on which cross connections can or do exist. Permit means a document issued by the department, which allows a cross connection installation. Person means any individual, corporation, company, association, trust, partnership, the commonwealth, a municipality, district, or subdivision or instrumentality of the United States, except that nothing herein shall be construed refer to or to include any American Indian tribe or the United States Secretary of the Interior in his or her capacity as trustee of Indian lands. Pressure vacuum breaker means an approved backflow prevention device designed to prevent only back siphonage and which is designed for use under static line pressure and which has necessary appurtenances for testing. Reduced pressure backflow preventer means an approved backflow prevention device incorporating: (1) Two more check valves; (2) An automatically operating differential relief valve located between the two checks; (3) Two shut-off valves; and (4) Necessary appurtenances for testing. Residential dual check means an assembly of two spring-loaded, independently operating check valves without tightly closing shut-off valves and test cocks. Generally employed immediately downstream of the water meter to act as a containment device. Reviewing authority means the department, its designee, or the local plumbing inspector, authorized by MGL chapter 142 and licensed by the board of state examiners of plumbers and gas fitters, whichever is responsible for the review and approval of the installation of an approved backflow prevention device.
(Ord. dated 7/5/05 (part))
Ask a question about Lawrence law
Corpus searches the Lawrence sections it holds and shows the ones that match, with their citations. Free, no sign-in.
