15.12.170 - Ventilation.

The owner shall provide for each habitable room, bathroom and toilet compartment, ventilation to the outdoors consisting of: A. Windows, skylights, doors or transoms in the exterior walls of roofs that can be easily opened to a minimum of four percent of the floor area of that habitable room, bathroom or toilet compartment; provided, that a skylight which, if open, exposes the interior of the dwelling to direct rainfall shall not qualify; or B. Mechanical ventilation capable of producing: 1. For each kitchen, 15 air changes per hour, 2. For each bathroom or toilet compartment, 12 air changes per hour, and 3. For each habitable room other than a kitchen, ten air changes per hour (See section 15.12.200).

(Prior code § 15-9)