§ 155-3 — Code additions, deletions and amendments
Code of Ordinances, City of Lowell, Massachusetts · Lowell Code of Ordinances § 155-3
Corpus is an independent public-information project, not the official City of Lowell website. Stable reference: corpuslaw.us/code/2daf3324-f0cf-4782-a0e4-00e08d97bcdb
§ 155-3: Code additions, deletions and amendments.
The following additions, deletions and amendments are made in the Fire Prevention Code adopted in this chapter: A. Section 1.2c, Application of Code, is added to read as follows: "MGL c. 148, as amended, shall take precedence over this Fire Prevention Code whenever any conflict arises which has the effect of reducing the requirements established under state law." B. Section 1.2d, Massachusetts Electrical Code, is added to read as follows: "All electrical work required by this Fire Prevention Code shall be installed in accordance with the applicable standards specified in the Massachusetts Electrical Code, as amended. All references to NFPA No. 70, National Electrical Code, 1962 edition, in this Fire Prevention Code shall be deleted." C. Section 1.9g, Permits, is added to read as follows: "Before a permit is issued by the Inspectional Services Department under the provisions of the Building Code, as accepted, for the construction of new buildings, alterations and additions to existing buildings, all plans, blueprints and specifications of these buildings shall be submitted to the Bureau of Fire Prevention to ensure that all necessary fire prevention and fire protection measures as the Chief of the Fire Department shall require in all such buildings are provided for, except in a one- or a two-story dwelling." D. Sections 5.1 to 5.9, Storage, Use, Handling and Transportation, are deleted entirely. E. Section 5.10, Safety Film Only, is amended by the following substitution and addition to read as follows: "The use, storage, handling and transportation of cellulose nitrate motion-picture film is prohibited anywhere within the City limits. Only motion-picture film marked 'Safety Film' shall be used, stored, handled or transported within the City limits." F. Section 12.4a is amended by adding a new subsection as follows: The following conditions shall be met before a blasting permit shall be issued by the Bureau of Fire Prevention: 1. | A copy of a bond as required under the provisions of MGL c. 148, §§ 20 and 20A must be produced by the contractor when applying for a blasting permit at the Bureau of Fire Prevention, said bond to be on file in the State Treasurer's office in the sum of $20,000 and dated the same year as the blasting permit is applied for. 2. | Competent operator must produce his certificate of competency and his number noted on the blasting permit. 3. | Blasting permits will be issued for only one location at a time, and a new permit must be applied for when moving to a new location for blasting operations. 4. | Each blasting permit shall be issued for a maximum period of only one week for each location, at the end of which time the blasting permit must be renewed. 5. | Before a blasting permit will be issued to any competent operator, the site where such blasting will take place must be surveyed by a member of the Bureau of Fire Prevention or a chief officer of the Fire Department to make sure that all conditions in Section 12.8 are being complied with. 6. | In certain congested districts the City Engineer will be consulted as to underground services to buildings, such as gas mains, water mains, sewers, electric cable, etc. 7. | Each blasting permit is subject to revocation by the Chief of the Fire Department or head of the Bureau of Fire Prevention whenever he deems it necessary for the safety of persons and property. 8. | No blasting permits shall be issued for areas where flammable and combustible fluids are stored underground. G. Section 16.23, Installation of Underground Tanks, is amended by adding a new subsection as follows: Section 16.23h 1. | Every tank shall be supported by a foundation capable of supporting the tank. 2. | The minimum distance from any part of a tank storing Class 1 liquids to any property line, which shall include streets, sidewalks or public ways, shall be not less than 10 feet. 3. | Each tank and the fittings connected thereto should be liquidtight and vaportight. 4. | All tanks and piping shall be tested for tightness as required in the provisions of Section 16.27c. This test shall be witnessed by a member of the Bureau of Fire Prevention, who shall make a record of the capacity, gauge thickness, Underwriters' Laboratories serial number and any other pertinent information relating to such tank. 5. | The tank exterior shall be covered with a rust-resistant material to prevent corrosion. 6. | All pipes connected to such tank shall be as required in the provisions of Section 16.23f and g. 7. | All pipe joints and connections shall be of the swing type or other approved type so that in case of undermining or settling of the tank the piping will not be damaged or broken. 8. | Each tank shall have a filler pipe, a draught pipe and vent pipe. Gauge pipes terminating inside a building shall be as required in Section 16.23g(2). 9. | Filler pipes shall be not less than 1 1/4 inches in diameter and should extend to within three inches from the bottom of the tank. The receiving end of the filler pipe shall be located outside the building and provided with a screw plug or cap and less than five feet away from any building opening. Such connection shall be liquidtight when not in use. When run to a sidewalk, alley or public way, the pipe shall terminate in a box with a metal cover set flush with surface of such sidewalk, alley or public way. This cover will be kept wrenchtight when not in use. 10. | Vent pipes shall be as required in Section 16.23c, 16.23d and 16.23e. 11. | When more than one tank is used, spacing between tanks shall be not less than five feet. 12. | Two copies of a plot plan showing tank locations, capacities, spacings, property lines, buildings, etc., shall be filed with the Bureau of Fire Prevention along with the application for a license or permit for said storage. 13. | A license shall be required for the storage of flammable fluids as defined in MGL c. 148. 14. | The capacity of such tanks shall not exceed that for which the license or permit was issued. 15. | All underground tanks containing a flammable fluid or vapor shall be removed from the ground when their use has terminated. A permit for the removal and transportation of such tanks must be obtained at the Bureau of Fire Prevention. Tanks must be properly capped and inspected by a member of the Bureau of Fire Prevention before being transported. 16. | Maximum storage limits for each location shall be at the discretion of the Chief of the Fire Department. H. Section 21.8, Containers Inside Buildings, is amended by adding a new subsection to read as follows: "Section 21.8b. Portable units for cooking or heating purposes using liquefied petroleum gas as a fuel shall be prohibited in miscellaneous halls, places of assembly, public buildings, public halls, special halls, theaters, hotels, motels or restaurants. The use of liquefied petroleum gas systems in any form is prohibited in the Lowell Memorial Auditorium and the Cawley Stadium." I. Section 28.15, Grease Duct Systems and Ventilation of Restaurant Cooking Equipment, is added to read as follows: Section 28.15a. Inspection of Systems. Ventilating systems, including ducts, hoods, fans, grease filters and other parts of such systems, shall be inspected periodically and cleaned as often as may be necessary to remove deposits of residue and grease and in any case at least twice a year in restaurants, kitchens, bakeries and other similar occupancies where greasy and oily substances accumulate in ventilating equipment. Section 28.15b. Fire Protection. Extensive exhaust duct systems as described in Section 28.15a shall be provided with an automatic Class B fire-extinguishing system; small installations using deep fryer, fry kettle or other kitchen equipment where grease may accumulate shall be provided with a fire extinguisher suitable for use on Class B fires or as directed by the head of the Bureau of Fire Prevention. J. Section 28.16, Laundromats, Coin-Operated, is added to read as follows: "All new and existing laundromats of the coin-operated type shall be required to maintain good housekeeping at all times, and all equipment such as washers, dryers and exhaust and duct systems shall be thoroughly cleaned of lint and other combustible materials at least once a week. Open areas above washers and dryers must be protected against the possibility of combustible materials being discarded in these areas." K. Section 29.1, Permits Required, is amended by adding a new subsection to read as follows: "Section 29.1a. Before a permit may be issued under the provisions of Section 29.1, a plot plan must be submitted to the Bureau of Fire Prevention showing the location where the tent is to be erected, location of nearest buildings, highways and access roads and location of nearest municipal fire hydrant, also the area in square feet the tent or tents will cover and the seating capacity of such tent or tents." L. Section 29.2 is amended by striking out the word "persons" in the first line and inserting in its place the word "firefighter" and by adding a new paragraph to read as follows: "The Chief of the Fire Department shall designate the number of portable fire extinguishers and hose lines for complete fire protection for such tent or tents to be manned by one or more fire fighters who will be designated by the Chief of the Fire Department for the protection of persons and property." M. Section 29.3a is amended by adding a new subsection to read as follows: "Each tent or tents shall have sufficient number of exits designated by the posting of the proper exit signs, and a secondary means of illumination must be provided if tents are to be used after dark, in case of a power failure." N. Appendix B is amended to read as follows: 1. | Methods. a. | Underground tanks taken out of service shall be safeguarded or disposed of by the following means: (1) | Placed in a temporary out-of-service condition. Tanks shall be rendered temporarily out of service only when it is planned that they will be returned to active service at the location or pending removal within 90 days. (2) | (Delete) (3) | Tanks removed. 2. | Records. a. | In cases where tanks are rendered temporarily out of service, records shall be kept of the date, tank size, location and method used for placing the tanks in a safe condition. With any of the methods described in Section 1, no cutting torch or other flame- or spark-producing equipment shall be used until the tank has been completely purged or otherwise rendered safe. In each case the steps given shall be carried out successively. 4. | Tanks Abandoned in Place (delete entire section)
[Amended 8-23-1988 ; 12-23-2008 ]
Ask a question about Lowell law
Corpus searches the Lowell sections it holds and shows the ones that match, with their citations. Free, no sign-in.