For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 272-17 — Requirements

Code of Ordinances, City of Lowell, Massachusetts · Lowell Code of Ordinances § 272-17

Corpus is an independent public-information project, not the official City of Lowell website. Stable reference: corpuslaw.us/code/d09816f3-ac40-47ca-81a0-5013389d46c8

§ 272-17: Requirements.

A. Water system. (1) The water system shall be considered as made up of two parts, the Utility system and the customer system. (2) The Utility system shall consist of the source facilities and the distribution system and shall include all those facilities of the water system under the complete control of the Utility, up to the point where the customer's system begins. (3) The source shall include all components of the facilities utilized in the production, treatment, storage, and delivery of water to the distribution system. (4) The distribution system shall include the network of conduits used for the delivery of water from the source to the customer's system. (5) The customer's system shall include those parts of the facilities beyond the termination of the Utility distribution system which are utilized in conveying Utility-delivered domestic water to points of use. B. Policy. (1) No water service connection to any premises shall be installed or maintained by the Lowell Regional Water Utility unless the water supply is protected as required by Massachusetts state law and this article. Service of water to any premises shall be discontinued by the Lowell Regional Water Utility if a backflow prevention device required by this article is not installed, tested and maintained or if it is found that a backflow prevention device has been removed or bypassed or if an unprotected cross-connection exists on the premises. Service will not be restored until such conditions or defects are corrected. (2) The customer's system should be open for inspection at all reasonable times to authorized representatives of the Lowell Regional Water Utility to determine whether cross-connections or other structural or sanitary hazards, including violations of this article, exist. When such a condition becomes known, the Executive Director of the Lowell Regional Water Utility shall deny or immediately discontinue service to the premises by providing for a physical break in the service line until the customer has corrected the condition(s) in conformance with state and City statutes relating to plumbing and water supplies and the regulations adopted pursuant thereto. All expenses relating to the disconnection and reconnection shall be at the customer's expense. (3) An approved backflow prevention device, where required, shall be installed on each service line to a customer's water system at or near the property line or immediately inside the building being served but in all cases before the first branch line leading off the service line wherever the following conditions exist: (a) In the case of premises having an auxiliary water supply which is not or may not be of safe bacteriological or chemical quality and which is not acceptable as an additional source by the Massachusetts Division of Water Pollution Control, the public water system shall be protected against backflow from the premises by installing a backflow prevention device in the service line appropriate to the degree of hazard.[1] (b) In the case of premises on which any industrial fluids or any other objectionable substance is handled in such a fashion as to create an actual or potential hazard to the public water system, the public water system shall be protected against backflow from the premises by installing a backflow prevention device in the service line appropriate to the degree of hazard. (c) In the case of premises having internal cross-connection that cannot be permanently corrected and controlled or intricate plumbing and piping arrangements or where entry to all portions of the premises is not readily accessible for inspection purposes, making it impracticable or impossible to ascertain whether or not dangerous cross-connections exist, the public water system shall be protected against backflow from the premises by installing a backflow prevention device in the service line. (4) The type of protective device required under Subsection B(3)(a), (b) and (c) shall depend upon the degree of hazard which exists as follows: (a) In the case of any premises where there is an auxiliary water supply as stated in Subsection B(3)(a) of this section, or where there is any material dangerous to health which is handled in a fashion as to create an actual or potential hazard to the public water system, or where there are "incontrolled" cross-connections, either actual or potential, the public water system shall be protected by an approved air-gap separation or an approved reduced-pressure-principal backflow prevention device at the service connector. (b) In the case of any premises where there is water or substance that would be objectionable but not hazardous to health if introduced into the public water system, the public water system shall be protected by an approved double check-valve assembly. (c) In the case of any premises where, because of security requirements or other prohibitions or restrictions it is impossible or impractical to make a complete in-plant cross-connection survey, the public water system shall be protected against backflow or backsiphonage from the premises by the installation of a backflow prevention device in the service line. In this case, maximum protection will be required; that is, an approved air-gap separation or an approved reduced-pressure-principal backflow prevention device shall be installed in each service to the premises. (5) Any backflow prevention device required herein shall be of a model and size approved by the Executive Director of the Lowell Regional Water Utility. The term "approved backflow prevention device" shall mean a device that is on the approved list of backflow preventers and double check valves as revised by the Massachusetts Division of Water Pollution Control or is on the University of Southern California Approval List. Said approval lists have been adopted by the Executive Director of the Lowell Regional Water Utility.[2] (6) It shall be the duty of the customer-user at any premises where backflow prevention devices are installed to have certified inspections and operational tests made at least once per year as required under Massachusetts regulations and this article. The Lowell Regional Water Utility will conduct testing on these devices twice a year. The owner of the device will be charged for these tests. The Lowell Regional Water Utility may have these tests performed by a designated representative. In those instances where the Executive Director of the Lowell Regional Water Utility deems the hazard to be great enough he may require certified inspections at more frequent intervals. These inspections and tests shall be at the expense of the water user and shall be performed by Lowell Regional Water Utility personnel or by a certified tester approved by the Executive Director of the Lowell Regional Water Utility and approved by the Commonwealth of Massachusetts. It shall be the duty of the Executive Director of the Lowell Regional Water Utility to see that these timely tests are made. The Executive Director of the Lowell Regional Water Utility shall notify the customer-user in advance when the tests are to be undertaken so that he or his representatives may witness the tests if so desired. These devices shall be repaired, overhauled or replaced at the expense of the customer-user whenever said devices are found to be defective. Records of such tests shall be kept by the Executive Director of the Lowell Regional Water Utility. (7) All presently installed backflow prevention devices which do not meet the requirements of this section but were approved devices for the purposes described herein at the time of installation and which have been properly maintained shall, except for the inspection and maintenance requirements under Subsection B(6), be excluded from the requirements of these rules so long as the Executive Director of the Lowell Regional Water Utility is assured that they will satisfactorily protect the Utility system. Whenever the existing device is moved from the present location or requires more than minimum maintenance or when the Executive Director finds that the maintenance constitutes a hazard to health, the unit shall be replaced by a backflow prevention device meeting the requirements of this section. (8) All industrial and commercial establishments attached to the Lowell water system will be required to install at the service entrance and immediately downstream of the meter a reduced-pressure backflow device. (9) All decisions relating to determination of backflow devices will be made by the Lowell Regional Water Utility. Failure to comply with any directive from this office will result in termination of service.

Ask a question about Lowell law

Corpus searches the Lowell sections it holds and shows the ones that match, with their citations. Free, no sign-in.