§ 82-92 — Definitions
Revised Ordinances of the City of Medford, Massachusetts (Codified through Ordinance No. 889, adopted April 16, 2024. (Supp. No. 18)) · Medford Revised Ordinances § 82-92
Corpus is an independent public-information project, not the official City of Medford website. Stable reference: corpuslaw.us/code/bb9ee1ac-7da7-4031-b960-251404c67829
Sec. 82-92. - Definitions.
The following words, terms and phrases, when used in this division, shall have the meanings ascribed to them in this section, except where the context clearly indicates a different meaning: Air gap separation means the method of preventing backflow through the use of an unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet supplying water to a tank, plumbing fixture or other device and the flood level rim of the receptacle. Approved means accepted by the reviewing authority as meeting an applicable specification stated or cited in this division, or as suitable for the proposed use. Approved backflow prevention device means a method to prevent backflow approved by the department for use in the commonwealth. Atmospheric vacuum breaker means an approved backflow device used to prevent backflow approved by the department for use in the commonwealth. Auxiliary water supply means any water supply of unknown or questionable quality on or available to the premises other than the supplier's approved public potable water supply. Back pressure means pressure created by mechanical means or other means which causes water or other liquids or substances to flow or move in a direction opposite to that which is intended. Backflow means the flow of water or other liquids, mixtures or substances into the distribution pipes of a potable water supply from any source other than the intended source. Backflow preventer with intermediate atmospheric vent means a device having two independently operating check valves separated by an intermediate chamber with a means for automatically venting it to the atmosphere, in which the check valves are forces loaded to a normally closed position and the venting means is force loaded to a normally open position. Backsiphonage means a form of backflow due to reduced or subatmospheric pressure within a water system. Barometric loop means a loop of pipe rising at least 35 feet, at its topmost point, above the highest fixture it supplies. Contaminant means any physical, chemical, biological or radiological substance or matter in water. Cross connection means any actual or potential connection between a distribution pipe of potable water from a public water system and any waste pipe, soil pipe, sewer, drain or other unapproved source. Cross connection control coordinator means a person employed by the city to coordinate all phases of the city's cross connection control program between the property owners, the city, and any and all contractors or subcontractors under contract with the city to perform surveys, tests, installations or repairs as outlined in this division and section 22.22, the Drinking Water Acts of the state department of environmental protection. Such coordinator must be a full-time employee of the city, must be a certified tester, and must possess a state plumber's license for at least five years. The coordinator must also possess designee status from the city water superintendent and/or the department of environmental protection. The CCCC shall be compensated for his services. Cross connection violation form means a violation form designated by the department, which is sent to the owner by the water supplier with copies sent to the department, plumbing inspectors, and board of health delineating cross connection violations found on the owner's premises and a procedure for corrective action. Delegated agent or representative means any individual approved by the director of public works who holds a current certificate as a backflow prevention device tester from the commonwealth. Department means the state department of environmental protection. Designee. See Delegated agent or Representative and Cross connection control coordinator. Director of public works means the director of public works in charge of the city water department invested with the authority and responsibility for the implementation of an effective cross connection control program and for the enforcement of the provisions of this division. Double check valve assembly means a backflow prevention device which incorporates an assembly of check valves, with shutoff valves at each end and appurtenances for testing. In-plant protection means the location of approved backflow prevention devices in a manner which provides simultaneous protection of the public water system and the potable water system within the premises. Owner means any person maintaining a cross connection installation or owning or occupying premises on which cross connections can or do exist. Permit means a document issued by the department which allows a cross connection installation. Person means any individual, corporation, company, association, trust, partnership, the commonwealth, a municipality, district, or other subdivision or instrumentality of the United States, except that nothing in this definition shall be constructed to refer to or to include any American Indian tribe or the United States Secretary of the Interior in his capacity as trustee of Indian lands. Pressure vacuum breaker means an approved backflow prevention device designed to prevent only backsiphonage, and which is designed for use under static line pressure, and which has necessary appurtenances for testing. Reduced pressure backflow preventer means an approved backflow prevention device incorporating: (1) Two more check valves; (2) An automatically operating differential relief valve located between the two checks; (3) Two shutoff valves; and (4) Necessary appurtenances for testing. Residential dual check means an assembly of two spring loaded, independently operating check valves without tightly closing shutoff valves and test cocks. Such assembly is generally employed immediately downstream of the water meter to act as a containment device. Reviewing authority means the department, its designee, or the local plumbing inspector, authorized by M.G.L.A. c. 142 and licensed by the board of state examiners of plumbers and gas fitters, whichever is responsible for the review and approval of the installation of an approved backflow prevention device.
(Ord. No. 568A, § 2.4.27, 8-4-1992)
Ask a question about Medford law
Corpus searches the Medford sections it holds and shows the ones that match, with their citations. Free, no sign-in.
