Sec. 2-197. - Same—Conductors.
(a) For the purpose of overhead construction, electric conductors are divided into the following four (4) classes: (1) High-voltage supply system conductors. (2) Low-voltage supply system conductors. (3) Communication system conductors. (4) Intelligence communications. (b) A distance of forty (40) inches shall be maintained between supply system conductors and communication system conductors at points of attachment to the same pole. (c) Service drop wires shall not be smaller than number eight (8) American wire gauge. This minimum shall apply to each conductor of a multi-conductor cable. (d) All conductors shall have weatherproof or equivalent covering. The provisions of this subsection shall not apply to the following: (1) Supply system conductors carrying thirteen thousand two hundred (13,200) volts or more. (2) Neutral conductors of service drop cables. (3) Effectively grounded neutral conductors. (4) Span lengths in excess of two hundred (200) feet. Whenever in the opinion of the inspector of wires the covering of conductors becomes impaired or unsightly, the owner shall renew such covered wire without unnecessary delay. (e) All tie-wires shall have a covering similar to that of the conductors they confine. Bare conductors shall be tied with bare wire. (f) No supply system conductor smaller than number six (6) American wire gauge, shall be used for outside construction between poles or supporting fixtures, except in the case of cables supplying street lights. (g) Unguarded high-voltage conductors shall not be run within three (3) feet, nor low-voltage conductors within four (4) inches of any pole, building or any other structure without being securely attached thereto, and insulated therefrom. (h) If any portion of a street light fixture or other part of supply system equipment can be touched by persons standing on the ground or roof of a building, or reaching from a door or window, it shall be insulated, guarded or grounded. (i) All supply and bare communication system conductors supported by the same crossarm and running in the same direction shall not be less than eleven (11) inches apart, and conductors adjacent to the pole shall not be less than thirty (30) inches apart, to enable linemen to pass up and down the pole freely and without danger of contact with such conductors. (j) Supply system conductors running in the same direction shall not be attached to both the upperside and underside of the same crossarm. (k) Conductors crossing from one side of the street to the other shall cross at right angles as nearly as physical conditions permit, and shall cross from arms or brackets secured to poles or supporting fixtures. When crossing from one building to another, they shall do so from the highest practicable point of the same. When crossing conductors of another owner, they shall pass either over or under, and not between such other conductors. They shall be drawn taut, and at least twenty (20) inches' separation from such other wires shall be maintained to avoid swinging contacts. (l) No conductor shall hang less than eighteen (18) feet from the street or sidewalk at the lowest point of sag. However, if a communication system service drop or an effectively insulated or grounded guy crosses a street, the clearance may be reduced to sixteen (16) feet at the side of the traveled way; and where communication system wires or cables cross over or run along alleys, the clearance may be reduced to fifteen (15) feet. (m) Where sharp angles occur in a line, or where it is necessary to run conductors so that the tendency is to lift the supports, appropriate means shall be employed to prevent such conductors from pulling away from their crossarms or other supports. (n) Conductors shall not be attached to chimneys and shall not be attached to or carried near fire escapes in such a way that they will interfere with the free use of the same, or be within reach of persons standing thereon. (o) Unused services and drop wires from supply system circuits which in the opinion of the inspector of wires constitute a nuisance or hazard to the public shall be removed by the owners thereof upon written notice from said inspector. Dead or unused wires not removed within a reasonable time after notice given by the inspector of wires may be removed by the inspector of wires at the expense of the owners. (p) Except as otherwise provided in this subsection, all overhead conductors, unless properly guarded, shall be at least eight (8) feet above the highest portion of flat-roofed buildings, or the ridge of pitched-roof buildings. With respect to pitched-roof buildings, the clearance shall be at least three (3) feet for supply system service cables carrying voltages not in excess of three hundred (300) volts and at least eight (8) inches for communication system conductors. (q) Whenever in the opinion of the inspector of wires any supply system overhead conductors, poles or supporting fixtures are in any unsafe or dangerous condition, the inspector will cause the current to be shut off forthwith, after notice to the owner thereof; and such defective conductors will then be treated as being dead and unused, and will be removed by the inspector at the expense of the owner thereof.
(Ord. of 5-9-91, § 3)
Ask a question about New Bedford law
Corpus searches the New Bedford sections it holds and shows the ones that match, with their citations. Free, no sign-in.