For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 604 — Electrical Facilities

Baltimore City Code (current through Ord. 26-129 (July 17, 2026); publication of Oct. 18, 2026) · Baltimore City Code, Building Codes, Part VII, Section 604

Corpus is an independent public-information project, not the official City of Baltimore website. Stable reference: corpuslaw.us/code/6980a4cf-bb47-4bb3-8461-675f65bbf53c

Section 604. Electrical Facilities

604.1 Facilities required. {As in IPMC} 604.2 Service. The size and usage of appliances and equipment serves as a basis for determining the need for additional facilities in accordance with the National Electrical Code. Dwelling units must be served by a three-wire, 120/240 volt, single-phase electrical service having a rating of not less than 60 amperes. 604.3 Electrical system defects. Inadequate service, improper fusing, insufficient receptacle or lighting outlets, improper wiring or installation, deterioration, damage, and similar defects in an electrical system must be corrected. 604.3.1 Abatement of hazards associated with water exposure. {Not Adopted} 604.3.2 Abatement of hazards associated with fire exposure. {Not Adopted}

Ask a question about Baltimore law

Corpus searches the Baltimore sections it holds and shows the ones that match, with their citations. Free, no sign-in.