Sec. 16-9. - Local amendments to International Plumbing Code.

(a) Chapter 2 Definitions. Section 202 Add the following definitions: DEAD ENDS. Drain Piping. In the installation of drain piping, dead ends shall not be permitted. EXCEPTION: Piping to make cleanouts accessible. Rough ins for future fixtures shall not be considered dead ends. If an existing fixture, appliance, or equipment is removed, any open ends in the drain piping shall be capped or plugged watertight. Vent Piping. In the installation, removal, or disconnecting of any vent piping, any open ends shall be capped or plugged watertight. Dead ends that are not self-draining shall not be permitted. Water. In the installation or removal of any part of the water distribution system, dead ends shall be prohibited. Future water distribution piping shall be allowed when valves are provided within 2' of the branch tee and are tagged as to their purpose. Valves shall be kept closed after testing until the branch lines are connected to approved fixtures. SERVICE SINK. A sink or receptor intended for custodial use capable of being used to fill and empty a janitor's bucket. Included are mop basins, laundry sinks, utility sinks, and similar fixtures. (b) Chapter 3 General regulations. 1. Section 305.4.1. Delete in its entirety and replace with: "Building Sewers shall be installed at an approved depth." 2. Section 306.1 Add to last sentence: "All drains, waste, vent, and storm piping below grade shall be bedded in a maximum of ½" stone at a depth of 4" under the pipe and covered to a depth of 6" above the pipe. 3. Section 312.1 Required Tests. Add to beginning of first sentence: "At the discretion of the code official the permit holder..." 4. Section. 312.9 Shower liner test. Delete in its entirety. 5. Delete and replace with, "Assemblies that are designed to be field tested shall be tested prior to final inspection. Assemblies installed in a building potable water supply distribution system for protection against backflow shall be maintained in good working condition and be repaired/replaced as necessary. Building/Property owners shall be responsible to have assemblies tested and maintained as required by the current plumbing code and the manufacturers installation instructions. repaired/replaced in accordance with the manufacturer's instructions and be retested. Testing of assemblies shall be performed by a licensed plumber with current approved backflow certification. Copies of the initial and annual test shall be sent to the code official. 6. Section 313 Equipment Efficiencies. Revise to read, "Equipment efficiencies shall be in accordance with the applicable provisions of the Maryland Building Performance Standards." 7. Section 314.1 Fuel burning appliances. Delete in its entirety and replace with, "Liquid combustion byproducts of condensing appliances shall be collected and discharged to an approved location." 8. Section 314.2.1 Condensate disposal Omit and replace with, "No AC condensate or gas flue condensate may discharge into sanitary sewer. AC or gas flue condensate may discharge to a splash block at grade, 10' from any adjacent property condensate shall be neutralized prior to discharge. (c) Chapter 4 Fixtures, Faucets and Fixture Fittings. 1. Section 404.1 Where required. Revise to read, "Accessible plumbing facilities and fixtures shall be provided in accordance with the applicable provisions of the Maryland Building Performance Standards." 2. Section 405.2 Access for cleaning Add subsection to read: "Urinals and service sinks shall not be installed where wall and floor surfaces are not waterproof and do not have a smooth readily cleanable, non-absorbent surface extending not less than 4' above the floor for a urinal and no less than 1' above the faucet for a service sink, and 1' to each side, and 1' in front Waterproofing are prohibited." (d) Chapter 5 Water Heaters. 1. Section 504.7 Required Pan. In first sentence, revise to say, "will cause structural damage" (e) Chapter 6 Water Supply and Distribution. Section 602.1 General. Revise end of sentence so it reads, "shall be provided with a potable supply of water with an approved backflow device in the amounts and at the pressures specified in this chapter." Add subsection, "Where a continuous water supply is critical and cannot be interrupted multiple backflows prevention devices or other means of maintaining a continuous supply shall be provided that does not create a potential cross connection." (f) Chapter 7 Sanitary Drainage. 1. Section 705.10.2 Solvent cementing. Delete exceptions. 2. Section 708.1.3 Building drain and building sewer junction. Add Subsection: "Building Sewer Junctions and the Property Line. "A cleanout shall be installed on the building sewer at the intersection of the property line." 3. Section 714.1 Backwater Valves. Add Subsection: " Notice of the Installation of Backwater Valves. When backwater valves are installed in building sanitary drainage systems, a notice shall be posted at the building water service shutoff valve(s) describing where backwater valves are located." (g) Chapter 9 Vents. 1. Section 903.1 Roof extensions. Insert "(Minimum 12") 2. Section 905.4 Vertical rise of vent Add 2 nd Exception: An approved dry vent may run horizontally on grade to a point where it turns vertical. The dry vent shall be connected at or above the centerline of the waste pipe. An accessible clean out shall be installed on the vertical portion of the dry vent at a minimum of 6" above the flood rim of the lowest fixture served." (h) Chapter 10 Traps, Interceptors and Separators. Section 1003.2 Approval. Add subsection: "An approved sampling station shall be installed on the outlet side of interceptors and separators in an accessible location approved by the code official." (i) Chapter 11 Storm Drainage. Section 1111.1 Subsoil Drains. Delete "Open-jointed" after "shall be". Add "Engineered" before "dry well".

(Ord. No. G-25-21, § I, 12-4-25)

Ask a question about Frederick law

Corpus searches the Frederick sections it holds and shows the ones that match, with their citations. Free, no sign-in.