Sec. 31-19. - Buildings and structures.
(a) In general. This section applies to the construction of new structures including the placement and replacement of manufactured homes and the substantial improvement of existing structures (including manufactured homes). (b) Special flood hazard areas. Structures that are located, in whole or in part, in any special flood hazard area must: (1) be designed (or modified) and constructed to safely support flood loads, including a complete load path capable of transferring all loads from their point of origin through the load-resisting elements to the foundation; (2) be designed, connected, and anchored to resist flotation, collapse or permanent lateral movement due to structural loads and stresses, including hydrodynamic and hydrostatic loads and the effects of buoyancy, from flooding equal to the flood protection elevation or the elevation required by these regulations or the building code, whichever is higher; (3) be constructed by methods and practices that minimize flood damage; (4) use flood damage-resistant materials below the elevation of the lowest floor required; (5) have the electric panelboard elevated at least 3 feet above the BFE; (6) comply with the requirements of the most restrictive designation if located on a site that has more than one flood zone designation; and (7) have electrical systems, equipment and components, and mechanical, heating, ventilating, air conditioning, and plumbing appliances, plumbing fixtures, duct systems, and other service equipment located at or above the elevation of the lowest floor required. Electrical wiring systems are permitted to be located below elevation of the lowest floor provided they conform to the provisions of the electrical code for wet locations. If replaced as part of a substantial improvement, electrical systems, equipment and components, and heating, ventilation, air conditioning, and plumbing appliances, plumbing fixtures, duct systems, and other service equipment shall meet the requirements of this section. Electrical systems, equipment and components, and heating, ventilating, air conditioning, and plumbing appliances, plumbing fixtures, duct systems, and other service equipment are permitted to be located below the elevation of the lowest floor provided they are designed and installed to prevent water from entering or accumulating within the components and to resist hydrostatic and hydrodynamic loads and stresses, including the effects of buoyancy, during the occurrence of flooding to that elevation.
(Ord. No. G-21-21, § I, 10-7-21)
Ask a question about Frederick law
Corpus searches the Frederick sections it holds and shows the ones that match, with their citations. Free, no sign-in.