§ 604 — BUILDING AND URBAN DESIGN STANDARDS
Code of the City of Frederick, Maryland (Codified through Ordinance No. G-26-1, adopted April 2, 2026. (Supp. No. 112, 8-26)) · Frederick Land Management Code § 604
Corpus is an independent public-information project, not the official City of Frederick website. Stable reference: corpuslaw.us/code/9d157ff3-2fbe-4764-8dc4-784dd43c6df5
Sec. 604 - BUILDING AND URBAN DESIGN STANDARDS
Purpose: Building design has a profound impact on functionality of the City's streets, human behavior, public health, and the appearance of City's corridors and neighborhoods. These criteria are not intended to restrict imagination, innovation, or variety, but rather to assist in focusing design principles, which can result in creative solutions that will develop a satisfactory visual appearance within the City, preserve taxable values, and promote the public health, safety and general welfare. This section establishes building and urban design standards that are consistent with the historic built form of the City, and that implement the following plan policies: LU.1.4 As supplemental guidance to the Comprehensive Plan, develop and adopt small area plans [that] … include a focus on enhancing community identity through urban design …. LU.9.3. Facilitate the development of communities that mix residential, institutional, commercial and office uses to provide convenience, increase opportunities for walking and transit service, and reduce the number and length of automobile trips. The non-residential uses in these communities should be compatible in design and scale with surrounding neighborhood development. LU.11.8 As part of the update to the City's development regulations, incorporate urban design guidelines. (a) Applicability. (1) In order to encourage mixed use development and to coordinate with the Performance Standards established in Article 4, Section 407, this section applies to any of the following applications: A. Any Master Plan; B. Any Site Plan that is submitted after Master Plan Approval; and C. An application for a conditional use permit to exceed the dimensional standards prescribed in Section 405: Dimensional and Density Regulations. (2) Upon submittal of a Master Plan, the applicant is required to provide a plan that addresses all of the Master Plan criteria in Article 11; Section 1115 Master Plan. (3) Details that are provided in Section 604: (b) through (d) are required to be placed on the site plan in detail. The site plan must reflect any approvals relative to the requirements of Article 11; Section 1115; however, more detail will be necessary with review of a site plan application. (b) Single-Family/Duplex Dwellings. (1) Applicability. A. Unless otherwise specified in this Code, this section applies to any of the following uses that are subject to the performance standards of Section 407B: Single-family dwellings; and Two-family dwellings/duplexes. B. This section applies to any other use where it is made applicable by a specific section of this Code. (2) Classification. The following classification system is adopted for the design elements listed below: A. Class A Dwellings (DR, DBO, DB, MXE, NC, and MU districts) mean dwellings that include at least six of the elements, prescribed below. B. Class B Dwellings (PND district) mean dwellings that include at least five of the elements, prescribed below. C. Class C Dwellings (RC, all R districts, RO, PB, MO, GC, and IST districts) mean dwellings that include at least four of the elements, prescribed below. (3) Elements. A. Front Elevation (subsection A below). B. Main Entrance (subsection B below). C. Vehicle and Pedestrian Areas (subsection C below). D. Driveways (subsection D below). E. Garages (subsection E below). F. Roofs (subsection F below). G. Exterior Finish Materials (subsection G below). H. Windows and Entryways (subsection H below). I. Other elements may be approved by the Planning Commission with a finding that the design is compatible with the intent of this section. A. Front Elevation. Dwellings shall include at least two of the following architectural elements in order to provide consistency with the architectural character of Frederick, and to avoid bland streetscapes: 1. Dormers; 2. Front porches; 3. Bay windows; 4. Balconies; or 5. Other alternative features that are approved by the Planning Commission after review of graphic and written documentation that is submitted with the Master Plan. B. Main Entrance. 1. Location of main entrance. The main entrance of each primary structure must face the street or courtyard. With buildings that have more than one main entrance only one entrance must meet this requirement. A building must include a front porch or stoop at all main entrances that face a street. The porch or stoop shall adjoin the main entrance, and the main entrance shall be accessible from the porch. 2. Porches. Porches used to satisfy the design criteria established herein shall comply with the following: a. Porches shall be covered by a roof. The roof shall not be located more than 12 feet above the floor of the porch. b. The covered area provided by the porch must be at least 20 square feet and a minimum of six feet wide. 3. Openings between porch floor and ground. Openings of more than one foot between the porch floor and the ground must be covered with an acceptable material that meets the purpose of this section and provides appropriate screening as determined by the Planning Commission. C. Vehicle and Pedestrian Areas, Generally. 1. Alleys. If the lot or dwelling is served by an alley, access to the garage for motor vehicles must be from the alley, not from a street frontage. 2. Location. Parking areas other than driveways may not be located in the front setback. Parking may be provided in the rear yard, and access may be provided through alleys, where the front yard is insufficient to accommodate a driveway. 3. Vehicle areas between the porch and the street. Except for driveways, vehicle areas may not be located between the building's porch or porches and an adjacent street unless an acceptable alternative is approved by the Planning Commission at the time of site plan approval. 4. Walkways. A walkway shall extend from the sidewalk or street to the main entrance. The walkway shall be at least three feet but may be wider to accommodate the design and functionality of the overall master plan with Planning Commission review and approval. D. Driveways. Restrictions on driveway areas are designed to avoid the domination of front yards by large expanses of impervious surfaces which increase stormwater runoff, create an environment that is hostile to pedestrian activity, and which creates visual blight. 1. Width and Size. Driveways and other impervious surfaces shall not comprise more than 50 percent of the front yard. In no event shall a driveway exceed 16 feet in width, except for shared driveways which may be 22 feet. 2. Driveway Entrances. Driveway entrances shall not comprise more than 50 percent of the front lot line and be in conformance with Table 601-2 Separation Standards. E. Garages. 1. Detached garages. Detached garages are consistent with the traditional design of Frederick's neighborhoods. These standards encourage detached garages as an alternative to front-loaded attached garages. a. Detached garages are permitted in any zoning district. Detached garages shall be located in the rear yard, and shall comply with the following standards. b. The garage walls shall not exceed the height of the principal structure. c. The garage shall not comprise more than 25 percent of the principal structure. d. The Planning Commission may modify this section with documentation that demonstrates the design is appropriate. 3. Street-facing garage walls. a. Applicability. This section applies to garages that are accessory to single-family dwelling units or duplexes. Where a proposal is for an alteration or addition to existing development, the standard applies only to the portion being altered or added. Garages that are accessory to attached houses, development on flag lots, or development on lots which slope up or down from the street with an average slope of 15 percent or more are exempt from this standard. b. Maximum Length and Size. The length of that portion of a garage wall facing the street shall not exceed 40 percent of the length of the street-facing building façade. There may be no more than two individual garage doors. On corner lots, only one street-facing garage wall must meet this standard. Where the street-facing façade of the building is less than 24 feet long, the garage wall facing the street may be up to 12 feet long if there is interior living area above the garage. F. Roofs. 1. Slope. Principal structures must have a visible roof that is sloped, with a pitch that is no flatter than four units of horizontal rise to 12 units of horizontal run. 2. Architectural Features. The roof of a principal structure shall include the following architectural details: a. At least one dormer facing the street. b. Dormers shall be of a size and scale of the particular architectural character of the project. 3. Roof Eaves. Roof eaves must project from the building wall at least eight inches, measured horizontally to face of gutter, on at least the front and rear elevations. The roof of no less than three attached units must be distinct from the other through either separation of roof pitches or direction, or other variation in roof design unless the Planning Commission allows a modification support by the overall design of the project. G. Exterior Finish Materials. 1. Plain concrete block, plain concrete, corrugated metal, are not allowed as exterior finish material. 2. Where horizontal siding is used, it must be shiplap or clapboard siding composed of boards with a reveal of three to nine inches, or vinyl or aluminum siding that is in a clapboard or shiplap pattern where the boards in the pattern are nine inches or less in width. H. Windows and Entryways. 1. At least 15 percent of the area of a street-facing facade excluding roof area and garage must include windows or main entryways. 2. All street-facing windows must meet the following requirements. Windows in rooms with a finished floor height four feet or more below grade are exempt from this standard. a. Windows shall have a vertical to horizontal ratio of at least one and one-half to one (1.5:1) but not more than four to one (4:1); or b. A horizontal window opening may be created when: • Two or more vertical windows are grouped together to provide a horizontal opening, and they are either all the same size, or no more than two sizes are used. Where two sizes of windows are used in a group, the smaller window size must be on the outer edges of the grouping. The windows on the outer edges of the grouping must be vertical; the center window or windows may be vertical, square, or horizontal; or • The windows are recessed into the face of the building and broken up with smaller panes of glass. 3. The Planning Commission may grant a modification of this requirement after review of graphic and written testimony providing other options that are in keeping with the character of the overall design of the project. (c) Multi-Family Dwelling Units. Purpose: The purpose of this section is to provide reasonable design standards for multi-family residential developments and single-family attached residential developments which: • Provide design flexibility; • Accommodate affordable housing for current and future residents of the City; • Protect the health, safety and general welfare of the general public and occupants of the units; • Protect the property values of surrounding dwelling units; • Promote a pedestrian-friendly, walkable streetscape; and • Provide for aesthetically pleasing development patterns. (1) Applicability. A. Unless otherwise specified in this Code, this section applies to any of the following uses that are subject to the performance standards of Section 407: Performance Standards. Multiple family dwellings; and Townhouses. B. This section applies to any other use where it is made applicable by a specific section of this Code. (2) Classification. The following classification system is adopted for the design elements listed below: A. Class A Dwellings (DR, DBO, DB, MXE, NC, and MU districts) shall include at least five of the elements, prescribed below. B. Class B Dwellings (PND district) shall include at least four of the elements, prescribed below. C. Class C Dwellings (RC, all R districts, RO, PB, MO, GC, and IST districts) shall include at least three of the elements, prescribed below. (3) Elements. A. Main Entrance (Subsection A Below). B. Vehicle and Pedestrian Areas (Subsection B below). C. Building Modulation (Subsection C below). D. Roofs (Subsection D Below). E. Exterior Finish Materials (Subsection E below). F. Windows and Entryways (Subsection F below). G. Other elements may be approved by the Planning Commission with a finding that the design is compatible with the intent of this section. Graphic and written justification must be submitted with the application for their review. A. Main Entry. Entryways shall face a street, sidewalk, or common area. Buildings shall not face the rear of other buildings on the same lot or parcel unless the rear does not include an entrance. B. Vehicle and Pedestrian Areas, Generally. 1. Pedestrian Facilities. Sidewalks shall be constructed within the interior of the development to link residential buildings with other destinations such as, but not limited to: parking, adjoining streets, mailboxes, trash disposal, adjoining sidewalks or linear parks and on-site amenities such as recreation areas. These interior sidewalks shall be constructed in accordance with the standards for sidewalks as set forth in Section 611(s) Street Improvement Standards. Sidewalks, in combination with curbs and gutters, shall be required adjacent to all public streets that provide access to the development. 2. Alleys. If the site is served by an alley, access to garage or off street parking for motor vehicles must be from the alley, not from a street frontage. 3. Vehicle areas between the porch and the street. Vehicle areas may not be located between the building's porch or porches and an adjacent street. 4. Walkways. A walkway shall extend from the sidewalk or street to the main entrance. The walkway shall be at least three feet but may be wider to accommodate the design and functionality of the overall master plan with Planning Commission review and approval. C. Building Modulation. The following standards shall apply to building design: 1. Building walls shall not exceed 200 feet in length or consist of more than ten units. 2. Facades of the individual units greater than 50 feet in length, measured horizontally, shall incorporate wall plane projections or recesses. Ground floor facades that face public streets shall have arcades, windows, entry areas, awnings, or other such features along no less than 60 percent of their horizontal length. 3. Multi-family buildings that face single-family homes shall be articulated at intervals consistent with the single family lot lines or the lot lines of the opposing block. [image omitted; see the official code] ——Long, continuous buildings have a "barracks" like character and are not permitted. ——The massing of buildings should be broken into smaller modules at the street level, especially where facing single-family homes. D. Roofs. 1. Slope. Principal structures must have a visible roof that is sloped, with a pitch that is no flatter than 12 units of horizontal run to four units of horizontal rise. 2. Architectural Features. The roof of a principal structure shall include the following architectural details: a. At least one dormer facing the street. b. Dormers shall be of a size and scale of the particular architectural character of the project. 3. Roof Eaves. Roof eaves must project from the building wall at least eight inches, measured horizontally from face of gutter, on at least the front and rear elevations. The roof of not less than three attached units must be distinct from the other through either separation of roof pitches or direction, or other variation in roof design. E. Exterior finish materials. 1. Plain concrete block, plain concrete, corrugated metal, plywood and sheet pressboard are not allowed as exterior finish material. Composite boards manufactured from wood or other products, such as hardboard or hardplank, may be used when the board product is less than six inches wide. 2. Where wood products are used for siding, the siding must be shingles, or horizontal siding, not shakes. 3. Where horizontal siding is used, it must be shiplap or clapboard siding composed of boards with a reveal of three to six inches, or vinyl or aluminum siding that is in a clapboard or shiplap pattern where the boards in the pattern are six inches or less in width. F. Windows and Entryways. 1. At least 15 percent of the area of a street-facing facade must include windows or main entryways. 2. All street-facing windows must meet the following requirements. Windows in rooms with a finished floor height four feet or more below grade are exempt from this standard. a. Windows shall have a vertical to horizontal ratio of at least one and one-half to one (1.5:1) but not more than four to one (4:1); or b. A horizontal window opening may be created when: • Two or more vertical windows are grouped together to provide a horizontal opening, and they are either all the same size, or no more than two sizes are used. Where two sizes of windows are used in a group, the smaller window size must be on the outer edges of the grouping. The windows on the outer edges of the grouping must be vertical; the center window or windows may be vertical, square, or horizontal; or • There is a band of individual lights across the top of the horizontal window. These small lights must be vertical and cover at least 15 percent of the total height of the window; or • The windows are recessed into the face of the building and broken up with smaller panes of glass. (d) Commercial and Institutional Buildings. (1) Applicability. A. Unless otherwise specified in this Code, this section applies to any commercial buildings that are subject to the performance standards of Section 407B. B. This section applies to any other use where it is made applicable by a specific section of this Code. C. This section does not apply to any of the following: 1. Car Wash. 2. Car, boat or marine craft dealers. 3. Flea markets (out-of-doors) or farmers markets. 4. Gasoline stations/Service stations. 5. Lumber yard and building material sales with outside storage, wholesale or retail. 6. Lumber yard and building material sales within enclosed buildings only, wholesale or retail. 7. Car Rentals. 8. Nurseries. 9. Vehicle repair and service. (2) Classification. The following classification system is adopted for the design elements listed below: A. Class A Buildings (DR, DBO, DB, MXE, NC, and MU districts) shall include at least seven of the elements prescribed below. B. Class B Buildings (PND district) shall include at least six of the elements, prescribed below. C. Class C Buildings (RC, all R districts, RO, PB, MO, GC, and IST districts shall include at least four of the elements prescribed below. (3) Elements. A. Building Orientation (Subsection A below). B. Building Structure/Alignment (Subsection B below). C. Frontage Buildout (Subsection C below). D. Building Modulation ( Subsection D below). E. Ground Floor Design (Subsection E below). F. Streetwall Standard (Subsection F below). G. Windows and Entryways (Subsection G below). H. Active Uses (Subsection H below). I. Mechanical Equipment (Subsection I below). J. Amenities (Subsection J below). K. Other elements may be approved by the Planning Commission with a finding that the design is compatible with the intent of this section. Graphic and written justification must be submitted with the application for their review. A. Building Orientation. Buildings subject to this section shall be oriented to the street. A building is "oriented to the street" where: 1. The distance from the sidewalk or, if there is not sidewalk, the street right-of-way line, to the nearest enclosed portion of the principal building or group of buildings does not exceed 20 feet. A street lot line or front lot line means any lot line that abuts a public street. 2. Principal entrances to buildings face a street or open to a square, plaza, or sidewalk. 3. All street level uses with sidewalk frontage are furnished with an individual entrance and direct access to the sidewalk in addition to any other access that may be provided. 4. No more than ten percent of the required off-street parking is located between the building's principal entrance and the street. 5. Pedestrian access from the public sidewalk, street right-of-way or driveway to the principal structure is provided through a paved surface. B. Building Structure/Alignment. 1. Buildings exceeding two stories shall incorporate a base, a middle, and a cap as described below: a. The base shall include an entryway with transparent windows as set forth in the Ground Floor Design Standards, below, and a molding or reveal placed between the first and second stories or over the second story. The molding or reveal shall have a depth of at least two inches and a height of at least four inches. b. The middle may include windows and/or balconies. c. The cap shall include the area from the top floor to the roof of the building, and shall include a cornice or a roof overhang. C. Frontage Build-out. At least 70 percent of the lineal area within the minimum and maximum front setback must be occupied by buildings. [image omitted; see the official code] D. Building Modulation Façade width shall not exceed the following: Table 604-4 Façade Width Zoning District/Development Technique/Comprehensive Plan Land Use Category | Maximum Façade Width (maximum) Average of all facades | Any Facade RO, NC, DB, DR, DBO, MU, TND | 30 feet | 60 feet PND, MXE | 40 feet | 80 feet PB, MO, GC | 60 feet | 120 feet Façade width refers the length of any facade that faces or is parallel to a public or private street. A "street" means a public street. "Façade" means the exterior side of a building and includes the entire building walls, including wall faces, parapets, fascia, windows, doors, canopy and visible roof structures of one complete elevation. The sum total of the façade areas on a lot may exceed the maximum façade width described in this section by dividing the buildings into two or more buildings, or into distinct "modules" that incorporate visible changes in the façade elevation through the use of wall plane projections, piers, columns, colonnades, arcades, or similar architectural features that create a distinct façade division. Each module shall have separate windows and entryways. [image omitted; see the official code] Large building broken into separate modules E. Ground Floor Design. The ground floor of the entryway shall align with the sidewalk elevation. Sunken terraces or stairways to a basement shall not constitute entryways for purposes of this subsection or subsection (9), below. It is not the intent of this section to preclude the use of below-grade entryways provided, however, that such entryways shall not constitute a principal entryway and shall not be used to satisfy the distancing requirements of subsection (9). F. Streetwall Standards. In order to bring buildings closer together, thereby forming a "streetwall" effect, the side setback shall be a minimum of zero (0) and a maximum of ten feet. G. Windows and Entryways. 1. Windows above the ground floor shall have a ratio of height to width of at least two to one (2:1). 2. The ground floors of all buildings shall be designed to encourage and to complement pedestrian-scale activity by the use of windows and doors arranged so that the uses are visible from and/or accessible to the street on at least 50 percent of the length of the first floor street frontage. Between 60 percent and 90 percent of the total surface area of the front elevation shall be in public entrances and windows (including retail display windows). Where windows are used, they shall be transparent. 3. Solid walls shall not exceed 20 feet in length. 4. All street level retail uses with sidewalk frontage shall be furnished with an individual entrance and direct access to the sidewalk in addition to any other access that may be provided. This standard shall not apply to any lot with a street frontage of less than 24 feet. 5. Doors shall be recessed into the face of the building to provide a sense of entry and to add variety to the streetscape. An entryway shall not be less than one square foot for each 1,000 square feet of floor area, and in all cases shall not be less than 15 square feet. 6. The maximum setback requirements may be waived by the Planning Commission or Department for an area not to exceed 90 percent of the frontage in order to accommodate courtyards. 7. Canopies, awnings, and similar appurtenances may be constructed at the entrance to any building, subject to the criteria established in the City's Building Code. H. Active Uses. In order to stimulate pedestrian activity, the first floor (street level) of any new building abutting a Major Arterial Street, Minor Arterial Street or major Collector Street shall devote at least 50 percent of the net first floor area to active uses. Residential dwellings shall be permitted above or below the first floor of any building with commercial and/or retail uses. I. Mechanical Equipment. Mechanical equipment, electrical meter and service components, and similar utility devices, whether ground level, wall mounted, or roof mounted, shall not be visible from the front property line. Exterior screening materials shall be the same as the predominant exterior materials as the principal building. In cases where the front property line is higher than the roof line of the subject building, no screening shall be required for a line of sight exceeding five foot six inches above the finished elevation of the building at the front property line. J. Amenities. At least one linear foot of seating shall be provided for each 50 linear feet of sidewalk or 200 square feet of open space area. For the purposes of this section, open space area shall include all areas in a lot not covered by a building footprint or parking areas. Seating dimensions shall comply with the requirements of the Americans with Disabilities Act and/or the Maryland Accessibility Code, as applicable. At least two of the following amenities shall be provided in an open space area: ornamental fountains, ornamental lamp posts, stairways, waterfalls, sculptures, or other public art, arbors, trellises, planted beds, drinking fountains, clock pedestals, awnings, or canopies.
(Supp. No. 3, Ord. No. G-06-26, § 19, 9-7-06)
Ask a question about Frederick law
Corpus searches the Frederick sections it holds and shows the ones that match, with their citations. Free, no sign-in.