For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 9-2 — Same—Amendments to State of Maryland Fire Prevention Code

Code of the City of Frederick, Maryland (Codified through Ordinance No. G-26-1, adopted April 2, 2026. (Supp. No. 112, 8-26)) · Frederick City Code § 9-2

Corpus is an independent public-information project, not the official City of Frederick website. Stable reference: corpuslaw.us/code/5afe7029-a793-48eb-9762-3032dd89c8c6

Sec. 9-2. - Same—Amendments to State of Maryland Fire Prevention Code.

(a) NFPA 1. Amend the NFPA 1 as follows: (1) Add Subsection 10.11.1.1.2 to read: Premises Identification. Minimum four inch high numbers shall be posted for residential premises and six inch high numbers shall be posted for commercial premises to meet the requirements of 10.11.1.1. Where buildings are set back from a roadway or fire lane or where a monument sign is proposed, number size and location shall be increased and located as necessary to be readily visible from the street and as approved by the authority having jurisdiction. (2) Add Subsection 13.1.5.2 to read: General. Newly installed fire department connections shall be located within 100 feet of a fire hydrant when required by the authority having jurisdiction. (3) Add Subsection 13.1.5.3 to read: General. Newly installed fire department connections shall be located in an approved location on the street side or the side of primary fire department vehicle access and shall be within 40 feet of an approved fire lane or street. (4) Modify Subsection 13.2.2.2 to read: New buildings shall be equipped with a Class I standard pipe system installed in accordance with the provisions of Section 13.2 where any of the following conditions exist: (1) more than two stories above grade where the building is protected by an approved automatic sprinkler system; (2) more than two stories above grade where the building is not protected by an approved automatic sprinkler system; (3) more than 50 ft (15 m) above grade and containing intermediate stories or balconies; (4) more than one story below grade; or (5) more than 20 ft (6.1 m) below grade. (5) Modify Subsection 18.2.3.5.3.2 to read: Turning Radius. Turns in fire lanes and fire department access roads shall maintain a minimum 25 foot inner and a minimum 50 foot outer radius. (6) Modify Subsection 18.2.3.6.1 to read: Marking of Fire Apparatus Access Road. Where required by the AHJ, fire lanes shall be marked with signs stating "FIRE LANE - NO PARKING." The sign shall be a minimum size of 12 inches by 18 inches and shall have red letters on a white background. Signs shall be placed at 50 foot intervals where required by the AHJ. In addition to signs, curbs and pavement shall be designated as fire lanes where required by the AHJ. Yellow traffic paint shall be used for this designation. (7) Add Subsection 18.5.1.7 to read: Fire Hydrants. Fire hydrants shall be provided for new construction and additions to existing construction so that all exterior portions of the new construction and/or addition are within 500 feet of a fire hydrant, measured by an approved route around the building exterior. (b) NFPA 101. Amend the NFPA 101 as follows: Modify Subsection 11.8.6.1 to read: Emergency Command Center. An emergency command center shall be provided in a location approved by the authority having jurisdiction and shall be directly accessible from the exterior of the building.

(Ord. No. G-25-22, § I, 12-4-25)

Ask a question about Frederick law

Corpus searches the Frederick sections it holds and shows the ones that match, with their citations. Free, no sign-in.