§ 10-22 — Structures

Code of the City of Gaithersburg, Maryland (Codified through Ordinance No. O-08-26, adopted September 8, 2026. (Supp. No. 52)) · Gaithersburg City Code § 10-22

Corpus is an independent public-information project, not the official City of Gaithersburg website. Stable reference: corpuslaw.us/code/5de78b03-ce36-4106-a16c-a86fbfc7fac7

Sec. 10-22. - Structures.

New structures (including buildings and the placement and replacement of manufactured homes) and substantial improvement of existing structures (including, and manufactured homes) and repetitive lost structures that are located, in whole or in part, in any special flood hazard area shall: (a) Be designed, constructed, and/or modified to safely support flood loads. The construction shall provide a complete load path capable of transferring all loads from their point of origin through the load-resisting elements to the foundation. (b) Be designed, connected and anchored to resist flotation, collapse or permanent lateral movement due to (i) structural loads and stresses, including hydrodynamic and hydrostatic loads and the effects of buoyancy; and/or (ii) from flooding equal to one foot or greater above the base flood elevation, or the elevation required by this chapter or the building code, whichever is higher. (c) Be constructed by methods and practices that minimize flood damage. (d) Use flood damage-resistant materials below the elevation of the lowest floor required in subsections 10-34(a) or 10-35(a). (e) Have electrical systems, equipment and components, and mechanical, heating, ventilating, air conditioning, and plumbing appliances, plumbing fixtures, duct systems, and other service equipment located at least one foot above the elevation of the lowest floor required in subsections 10-34(a) or 10-35(b). Electrical wiring systems are permitted to be located below elevation of the lowest floor provided they conform to the provisions of the electrical part of the building code for wet locations. If replaced as part of a substantial improvement, electrical systems, equipment and components, and heating, ventilation, air conditioning, and plumbing appliances, plumbing fixtures, duct systems, and other service equipment shall meet the requirements of this section. (f) As an alternative to subsection (e), electrical systems, equipment and components, and heating, ventilating, air conditioning, and plumbing appliances, plumbing fixtures, duct systems, and other service equipment are permitted to be located below the elevation of the lowest floor provided they are designed and installed to prevent water from entering or accumulating within the components and to resist hydrostatic and hydrodynamic loads and stresses, including the effects of buoyancy, during the occurrence of flooding to that elevation. (g) Have the electric panelboard elevated at least three (3) feet above the base flood elevation. (h) Comply with the specific requirements of article V. (i) Comply with the requirements of the most restrictive designation if located on a site that has more than one flood zone designation (A zone, designated floodway).

(Ord. No. O-10-15, 10-19-15; Ord. No. O-6-24, 11-4-24)

Ask a question about Gaithersburg law

Corpus searches the Gaithersburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.