For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 24-4.6 — MXD zone, mixed use development

Code of the City of Gaithersburg, Maryland (Codified through Ordinance No. O-08-26, adopted September 8, 2026. (Supp. No. 52)) · Gaithersburg City Code § 24-4.6

Corpus is an independent public-information project, not the official City of Gaithersburg website. Stable reference: corpuslaw.us/code/9b5980e4-e554-4f02-924b-9e39f347b540

Sec. 24-4.6. - MXD zone, mixed use development.

(A) Purpose. It is the objective of this zone to provide a more flexible approach to the comprehensive design and development of multi-use projects more so than the procedures and regulations applicable under the various conventional zoning categories. The specified purposes of this zone are: (1) To encourage orderly, staged development of large-scale comprehensively planned multi-use developments by providing procedures for various zoning and plan approvals, including development phasing; (2) To encourage design flexibility and coordination of architectural style of buildings and uses; (3) To ensure the integration and internal and external compatibility of applicable residential and nonresidential uses by providing a suitable environment that is enhanced and complemented by uses such as commercial, recreational, open space, employment, and institutional uses and amenities within a multi-use development; and (4) To encourage the efficient use of land by: (a) Locating employment and commercial uses convenient to residential areas; (b) Reducing reliance upon automobile use and encouraging pedestrian and other nonvehicular circulation systems; (c) Retaining and providing useable open space and active recreation areas close to employment and residential populations; and (d) Providing a multi-modal connectivity system among various uses. (B) Minimum locational requirements. (1) No land shall be classified in the mixed use development (MXD) zone, outside of annexations and comprehensive rezonings, unless the land is within an area for which there is an approved and adopted land use master plan which recommends mixed use development zoning for the land. (2) Approval of the MXD zone for land that is not recommended for this zone in an approved master plan may be rezoned to MXD but shall require the affirmative vote of four members of the city council upon a finding that the subject land and associated proposed development meets the purposes and objectives of the zone. (C) Development standards. (1) Minimum area. No land shall be classified in the MXD zone unless it contains a minimum of ten (10) acres. Parcels or tracts less than the minimum acreage may be permitted if they are contiguous to an existing MXD zoned area and can be harmoniously integrated into the MXD area, consistent with the objectives and purposes of this zone. Such parcels are not required to contain multiple uses but should contribute to a multi-use development and are subject to the provisions of section 24-12.4(D). (2) Frontage on public streets. Notwithstanding anything to the contrary contained in this chapter, lots in this zone shall not be required to have direct access to a public street provided that they are designed in such a way as to foster the purposes and objectives of this zone and that access to a public street is provided over private rights-of-way. (3) Residential density. The residential density in the MXD zone shall not exceed the residential density or total number of dwelling units stated in the applicable master plan, if any. The total number of dwelling units and the corresponding overall maximum density, as well as the approximate location of such units, shall be established at the time of sketch plan approval. (4) Commercial, employment, and industrial density. The commercial/employment/industrial density in the MXD zone shall be compatible with any gross floor area or floor area ratio recommended in the applicable area master plan or special conditions or requirements, if any are stated therein. The maximum density and uses of commercial/employment/industrial development shall be established at the time of sketch plan approval. (5) Dimensional standards (where recommended). All right-of-way requirements, setbacks, height limits, open space, or buffer areas recommended in an applicable master plan or special conditions or requirements stated therein to, in part, protect properties adjacent to the MXD-zoned areas shall be incorporated into all plans subject to approval under the zone. (6) Dimensional standards (where not recommended). Where setback, height limits, open space, or buffer areas are not recommended in an applicable master plan or special conditions or requirements stated therein to in part, protect properties adjacent to the MXD-zoned areas, such standards shall be established at schematic development plan approval. The following requirement shall be incorporated into all plans subject to approval under this zone: No building proposed for commercial/employment/industrial use shall be constructed less than sixty (60) feet from any adjoining property not zoned MXD that is recommended for residential zoning and land use in an applicable master plan. (D) Minimum open area, landscaping, and amenity requirements. (1) The amount of open area as defined in article 16, including designated parks, public and private open space, and active and passive recreational areas, required for the residential portion of a mixed-use development shall be not less than forty (40) percent of the total area shown for solely residential uses. (2) The minimum open area requirement, including designated parks, public and private open space, and active and passive recreational areas, for the commercial/employment/industrial portion of a mixed-use development shall be not less than twenty-five (25) percent of the total area devoted solely to commercial/employment/industrial uses. (3) The minimum open area requirement for mixed-use areas, combining residential and non-residential uses in a vertical or horizontal configuration on or in the same lot, parcel, block, or building, shall be not less than thirty-five (35) percent. (4) The city council may reduce the open area requirements upon a finding that comparable amenities and/or facilities may be provided in lieu of open area and that such amenities or facilities are sufficient to accomplish the purposes of the zone, and would be more beneficial to the proposed development than strict adherence to the specific open area requirement. (E) Public facilities and utilities. (1) A development in the MXD zone shall conform to any public facilities recommended for the site in an approved and adopted master plan, including granting such easements or making such dedications to the public as may be shown thereon or as shall be deemed necessary by the city to ensure the compatibility of the development with the surrounding area and to assure the ability of the area to accommodate the uses proposed by the application. (2) All utility lines in the MXD zone shall be placed underground. The developer or subdivider shall ensure final and proper completion and installation of utility lines. Poles and lamps for street lighting shall be provided by the developer in accordance with the approved site plan. (3) All streets, both public and private streets, including alleys, shall be shown on the schematic development plan and the final site plan, respectively. (F) Parking requirements. (1) Off-street parking shall be provided in accordance with Article 7 of this chapter, except as may be otherwise authorized. (2) The city council, at the time of schematic development plan review, shall determine the appropriate approximate number of spaces or parking ratios for specific uses. At the time of final site plan approval, the planning commission shall determine the final number of spaces. (3) The planning commission may reduce the number of spaces required for any use in accordance with section 24-7.6 of this chapter where such reduction will meet the purposes of the MXD zone. (G) Application for MXD zone and sketch plan approval. An applicant shall file together, with the prescribed application fee, an application for the establishment of the MXD zone pursuant to the provisions of section 24-12.3, Zoning map amendments and zoning text amendments to chapter 24, and as part of this application for separate approval, a sketch plan pursuant to the provisions of section 24-4.2, Floating zones, and section 24-12.4, MXD zone and sketch plans. (H) Application for sketch plan only. For applications seeking approval of a sketch plan not in conjunction with a zoning map amendment, an applicant shall file an application for a sketch plan pursuant to the provisions of section 24-4.2, Floating zones, and section 24-12.4, MXD zone and sketch plans. Decision criteria for sketch plan approval when not part of a map amendment. The city council may approve a sketch plan only upon finding that: (1) The application meets or accomplishes the purposes, objectives, and minimum standards and requirements of the zone; and (2) The application is in accord with recommendations in the applicable land use master plan for the property and is consistent with any special conditions or requirements contained in said land use master plan; and (3) The application will be internally and externally compatible and harmonious with existing and planned land uses in the areas within the proposed rezoning and adjacent areas; and (4) The application, if approved, would reflect the goals and intent of the city's strategic plan. (I) Application for schematic development plan approval. Following the approval by the planning commission and city council of the sketch plan, an application for a schematic development plan shall be filed for approval by the city council pursuant to the provisions of section 24-12.5, Schematic development plans. (J) Regulations or design guidelines adopted as part of schematic development plans. (1) The city council shall adopt design guidelines as part of a schematic development plan and approval resolution for a project in the MXD zone that include, at a minimum, architectural standards, but may include other requirements or standards such as: (a) Building/structure setbacks and lot coverage; (b) Signage; (c) Amenity programming; (d) Public art; (e) Landscaping and open areas. (2) The provisions of this section shall apply to any existing sketch or schematic development plan previously approved by the city council for the MXD zone which contains such rules, regulations, and standards. (3) No person, firm, or corporation may violate any such rules, regulations, or standards and any such violation shall be enforceable by the city and subject to such enforcement and penalties provided by chapter 1, sections 1-9 through 1-11, inclusive, of this Gaithersburg City Code.

(Ord. No. O-5-24, 7-15-24)

Ask a question about Gaithersburg law

Corpus searches the Gaithersburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.