Sec. 5-11. - Modifications to the International Mechanical Code (2021).

The International Mechanical Code (2021), adopted by section 5-10, is hereby modified by the city as follows: (1) General. Whenever the words "name of jurisdiction" or "authority having jurisdiction" appear in this code, insert the words "the City of Gaithersburg". (2) General. Whenever the words "building official" appear in this code, they shall be deemed to mean the city manager or designee. (3) General. Whenever the words "department" or "department of building safety" appear in this code, they shall be deemed to represent the City of Gaithersburg, Department of Planning and Code Administration, Permits and Inspections Division. (4) General. Delete all references to "the ICC Electrical Code" in this (IMC) or any other International Code adopted by this ordinance, and replace with "the City of Gaithersburg Code, Chapter 7, Electricity." (5) Chapter 1. SCOPE AND ADMINISTRATION. Section 101. GENERAL. Administration of the City Mechanical Code shall be performed exactly as described in Section 5-3 of the City Building Code, as adopted by this ordinance. (6) Subsection 101.1. Title. The (Name of Jurisdiction) shall be "the City of Gaithersburg, MD". (7) Subsection 101.2. Scope. Insert after the second sentence Mechanical systems in existing buildings, as defined by the Maryland Building Rehabilitation Code, undergoing repair, alterations, or additions, and change of occupancy shall be permitted to comply with the International Existing Building Code. References to the International Fuel Gas Code shall be replaced by the phrase "Regulations Governing the Installation of Plumbing, Gasfitting and Sewer Cleaning in the Washington Suburban Sanitary District," as published by The Washington Suburban Sanitary Commission (WSSC). Add a new sentence at the end of the subsection to read, "Fuel-gas piping systems, fuel gas appliances, gaseous hydrogen systems and related accessories are regulated under the authority of Washington Suburban Sanitary Commission (WSSC)." "The Provisions of the International Fuel Gas Code shall apply only in instances that are not governed by WSSC regulations." (8) Subsection 101.4. Applicability. Add new Subsection 101.4.3. 101.4.3. Severability: The provisions of these regulations are severable. If a court of competent jurisdiction holds that a provision is invalid or inapplicable, the remainder of the regulation remains in effect. (9) Section 103. Code Compliance Agency. Section 103.1. Delete in entirety Section 103.1 and substitute the following: 103.1 Creation of Agency. The City of Gaithersburg Planning and Code Administration is responsible for enforcing the provisions of this code. The director of the City of Gaithersburg Planning and Code Administration or the director's authorized designee shall be known as the City building official. (10) Subsection 106.4.3. Expiration. Delete in entirety. (11) Subsection 106.4.4. Extensions. Delete in entirety. (12) Reserved. (13) Subsection 104.4. Inspections. Subsection 104.4.1. Third Party Inspections. Add new Subsections 104.4.1, and 104.4.2., to read as follows: 104.4.1.1. Applicability: The Certified (Third-Party) Inspections Program is the City of Gaithersburg, MD's policy for "third-party" inspections of commercial and residential projects requiring construction or maintenance inspections by City Inspections staff. This program is pursuant to the Code of the City of Gaithersburg, MD., and the International Building Code, and also applies to projects using the International Existing Building Code. Questions may be directed to Inspections staff, (301) 258-6330. Exception. This program does not apply to construction under the Special Inspections Program, nor to new residential construction of Groups R-3 or R-4 within the scope of the International Residential Code, nor to fire detection, fire protection or fire suppression systems, nor to inspections by other City agencies. 1. The Certified Inspections Program offers property owners and construction contractors of commercial and residential construction projects the option for certain construction inspections to be performed and certified by private sector "third-party" engineers and inspectors, to the extent specified below, when approved in advance by the City of Gaithersburg. The Inspections staff will accept, review and approve such certified inspections, in lieu of inspections by Inspections staff, except in situations where there is specific cause that a particular report shall be rejected. The Inspections staff will monitor the quality of the certified inspections. The Inspections staff will continue to provide full support to inspection requests for projects not involved in this certified inspections program. 2. Private sector "third-party" inspection firms and personnel shall be employed directly by the project owner, shall be independent of the project architect or engineering design firm or contractors performing the work, and shall have no personal financial interest in the project. The building official, on a project-by-project basis, shall approve both the inspection firm and its personnel prior to commencement of construction. 104.4.2. Personnel Credentials. Inspections shall be conducted under the direct supervision of, and certified by, a Registered Design Professional, licensed in the State of Maryland. The Registered Design Professional and Registered Design Professional's field inspector personnel shall all possess appropriate State of Maryland or International Code Council, Inc. (ICC) inspector credentials. An inspector or Registered Design Professional approving work that is not in conformance with the City-approved plans and the Code of the City of Gaithersburg, MD. may lose City approval to perform future inspections. (14) Subsection 109. Fees. Delete in entirety. (15) Subsection 110.2. Temporary Connection. Delete "water system or sewer system" in the sentence. Following the first sentence, add "All water and sewer system connections, temporary or permanent, per WSSC policy." (16) Subsection 112.2.2. Add the following to the end of the paragraph: Any overtime inspection request(s) must be made a minimum of 48 hours in advance. (17) Section 113. MEANS OF APPEAL. Delete in 113.1, 113.2, 113.3, and 113.4, in entirety. Add new Subsection 113.1. as follows: "Subsection 113.1. General. Any decision or order of the City Manager or duly appointed designee under this chapter may be appealed within 17 days of the date of such decision or order to the City Board of Appeals. Any decision of the City Board of Appeals may be appealed to the Circuit Court within 30 days of the date of the Board's written decision. The Maryland Rules of Procedure shall govern such appeals. Any decision of the Circuit Court may be appealed to the appellate courts of this state." (18) Section 113.1. Add new Subsection 113.1.1. as follows: "Subsection 113.1.1. Means of Appeals. Any decision or order of the City Manager or duly appointed designee under this chapter may be appealed within 17 days of the date of such decision or order to the City Board of Appeals. Any decision of the City Board of Appeals may be appealed to the Circuit Court within 30 days of the date of the Board's written decision. The Maryland Rules of Procedure shall govern such appeals. Any decision of the Circuit Court may be appealed to the appellate courts of this state." (19) Subsection 115.4. Violation penalties. Delete the ensuing words following "specify offense" and insert "subject to penalties as described by law". Persons found guilty of a municipal infraction, enforceable and punishable by a fine and/or penalty as established by the Mayor and City Council pursuant to Sections 1-9 through 1-11 of the City Code. Each day that a violation exists shall be deemed a separate offense." "In addition thereto, the City may institute injunctive, mandamus, or any other appropriate action or proceedings at law or equity for enforcement of this Chapter, or to correct violations of this Chapter, and any court of competent jurisdiction shall have the authority to issue restraining orders, temporary or permanent injunctions or mandamus or other appropriate form of remedy or relief." Add the following at the end of the section. "In addition thereto, the City may institute injunctive, mandamus, or any other appropriate action or proceedings at law or equity for enforcement of this Chapter, or to correct violations of this Chapter, and any court of competent jurisdiction shall have the authority to issue restraining orders, temporary or permanent injunctions or mandamus or other appropriate form of remedy or relief." (20) Add Subsection 116.4.1. Unlawful continuance. Any person who shall refuse to leave, chooses to interfere with the evacuation of other occupants, or continue any operation after having been given an evacuation order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be deemed guilty of a municipal infraction, and shall be subject to a fine as provided in the city schedule of fees. (21) Section 202. GENERAL DEFINITIONS. Add term "Authority Having Jurisdiction" (AHJ). AUTHORITY HAVING JURISDICTION" (AHJ). An organization, office, or individual responsible for enforcing the requirements of a code or standard, or for approving equipment, materials, an installation, or procedure. Further defined under 2021 IBC Section 104, Duties and Powers of Building Official. (22) Subsection 302.6. Add new Subsection 302.6 Subsection 302.6. Supports and Anchorage. All appliances located on roofs shall rest on a manufacturer's standard perimeter support, self-flashing roof curb, framed steel support, or 4 X 4 treated lumber as a minimum. The appliances shall be securely affixed in an approved manner to resist vibration and wind loads. (23) Add new Section 304.13. MECHANICAL EQUIPMENT SCREENING to read as follows: Section 304.13. MECHANICAL EQUIPMENT SCREENING. 304.13.1. Applicability. This section provides the applicable standards for the screening of all equipment (may include projections or accessories to equipment), located on the roof of a building, in all zoning districts within the City, at the time of new installation or any equipment replacement. Screening shall be of a material similar in quality and appearance to other areas of the building façade and which is an integral part of the building's architectural design. Types of equipment defined shall include, but is not limited to elevator shafts, heating and air conditioning units of any type, ventilation ducts and exhaust air and make-up air vents, water tanks, cooling towers, swimming pool and spa pumps and filters, transformers and generators, and similar equipment (excluding solar collectors, wind energy, or similar renewable energy devices, and related equipment), and shall be screened from public view and adjacent residential districts, and shall comply with the requirements below. 304.13.2. Requirements. 1. Screening of Rooftop Equipment. Roof-mounted mechanical equipment shall not be visible in any direction (360 degrees) from a public property, a public right-of-way (from the opposite side of the abutting Primary Street), or adjacent residential property, as may be seen from a point six feet above ground level, perpendicular to the zone lot line. All screening for buildings designed (including parapet walls or other similar architectural elements) shall be constructed to a height of not less than one (1') foot above the horizontal plane of the highest (after-installation height) roof-mounted mechanical unit, HVAC and/or other equipment. Additional height screening of the top of roof-mounted mechanical equipment may be required by the City, if necessary to protect views from a residential zoning district located at a higher elevation. If free clearance or otherwise unobstructed flow or space is required by the Fire or Building Code, equipment should be positioned beyond the parapet wall so as not to be visible. Exception to Screening Requirement. Where it can be clearly demonstrated that the exterior roof-mounted or ground-mounted mechanical equipment is not visible from any public right-of-way, public property, or residential property in a residential zoning district, the City Building Official may waive the screening requirements of this section. The submittal of a plan and section/elevation drawing must document that the rooftop mechanical equipment is not visible from the opposite side of the abutting Primary Street's right of way. Submitted drawings shall indicate the point of measure and height of the mechanical screening, where applicable. 2. Large mechanical equipment, including refrigeration units for commercial, institutional and recreational buildings shall be incorporated into the building design or, alternatively, screened with the appropriate materials. Screening of roof-mounted equipment may be accomplished by solid and permanent roof-mounted screens, or with mechanical roof wells recessed below the roof line. 3. Significant heritage buildings shall have all rooftop equipment fully screened and/or integrated into the building in a way that respects and complements the building's heritage and architectural features. Screening shall be compatible with the style, materials, and color of the building upon which the equipment is located, subject to the approval of the City. 4. The elevation plans for the screening shall be submitted to, and approved by, the planning staff of the Planning and Code Administration, prior to building permit application. Site lines will be taken into consideration in determining approval of screening proposals." 5. Equipment setback from roof edges that is at least three (3) feet in depth for each one (1) foot of equipment height. 6. The construction plans for the screening must demonstrate conformance with all applicable provisions of this code (IBC) and the City Mechanical Code (IMC), and must meet any requirements for space, ventilation, or other requirements as dictated by the equipment manufacturer. 7. Exterior Noise. Roof-mounted and ground-mounted mechanical equipment shall be subject to Exterior Noise Standards. Mechanical equipment within mixed-use or commercial zoning districts shall be located so that the impact of noise on residential uses within the development and on adjacent residential uses is minimized to the greatest extent feasible in compliance with Exterior Noise Standards. 8. Ground-Mounted Mechanical Equipment. This section provides standards for the screening of mechanical equipment. Multi-unit residential and nonresidential land uses shall comply with the requirements of this section. Where mechanical equipment is allowed to be installed on ground, these items shall be screened from public view and adjacent residential districts with fences, walls, solid hedges, (subject to any allowed encroachments and/or zoning setback requirements), or other methods approved by the City. Screening shall be maintained in good condition at all times. Landscaping used as screening shall provide a dense, year-round screen. Chain link fencing with or without slats shall not be permitted. (24) Add new Section 304.14 WEATHER PROTECTION to read as follows: 304.14 WEATHER PROTECTION. Provisions such as louvers, louver blades or flashing shall be made to protect the mechanical and electrical equipment and the building interior from the elements. Mechanical units, ducts, piping, or structures installed or replaced on roofs shall be being properly supported by curbs, pads, bases, or piers which shall be flashed to the roofing in a watertight manner. All unsupported sections of mechanical equipment shall be a minimum of twelve (12) inches (304.8 mm) above the plane of the roof so that they will not obstruct the re-roofing process. Mechanical units shall properly connect to heating, air handling, refrigeration, and ventilation equipment, including fans, blowers, and similar types of equipment. Units shall be so located that proper drainage from the roof will not be blocked or impeded. Roof openings surrounded by curbs shall be sheathed over solidly and covered with a minimum of twenty-six (26) gauge metal approved for the use, or of equal material. All seams and mitered corners shall be constructed in a watertight manner. Such curbs shall be a minimum of nine (9) inches (228.6 mm) in height. (25) Subsection 306.1. Add new Subsection 306.1.1 Subsection 306.1.1. Heating Appliances. Electric, fossil or solid fuel fired appliances shall not be installed under any stairway or landing. (26) Subsection 306.3. Appliances in attics. After the last sentence, add the following: Access to the attic opening shall be provided by a permanent or pull-down stairway (subject to IECC insulation requirements) in all new construction. In existing installations, portable ladders shall be acceptable. (27) Subsection 504.1.1. Add new Subsection 504.1.1. Subsection 504.1.1. Dryer Duct Installation. Exhaust ductwork shall be installed in strict accordance with the dryer manufacturer's instructions. Ductwork installed in an unconditioned area shall be insulated to reduce condensation and potential lint build-up within the duct, and shall slope downward toward the exterior. These ducts shall be similarly insulated to IECC Section 403.3.1 requirements (R6) for unconditioned areas for a minimum of 6 feet from the exterior wall where located outside of the "conditioned" envelope. (28) Reserved. (29) Subsection 506.1. At the end of the first sentence, add the following: "and NFPA 96 in accordance with Chapter 11, City Code Chapter 11, the City Fire Safety Code. Add the sentence "Where discrepancies occur, the most stringent requirement will apply." after the first sentence. (30) Subsection 506.3.2.5. Change "light test" to "smoke test". Delete 2nd paragraph. (31) Subsection 506.3.9. Change the heading of the Subsection title to "Grease Duct Vertical and Horizontal Cleanouts." In item #1, change "20 feet" to "12 feet". Add item # 8 to read, "Vertical rises where personnel entry is not possible, adequate access for cleaning shall be provided on each floor level." (32) Subsection 506.3.12. Grease Duct Fire-Resistive Access Opening. After the last sentence, add "Follow NFPA 96 section 7.8.3 for additional termination requirements." (33) Subsection 507.1. General. At the end of the first sentence, add the phrase, Chapter 11, the City of Gaithersburg Fire Safety Code." (34) Subsection 606.2.1. Return Air Systems. Add the words "Supply and" to the beginning of the heading. Add the words "supply and" to the beginning of the heading. Add the words, "supply and" after the words, "in" in the first sentence. Add the following: "Smoke detectors shall be placed in air distribution systems as required by Chapter 11, the City of Gaithersburg Fire Safety Code," referencing NFPA 90A. Under the heading Exception, add the words "Return air:" to the beginning of the first sentence. After the last sentence, add "Smoke detectors shall not be required for fan units whose sole purpose is to remove air from the inside of the building to the outside of the building. (NFPA 90A)." (35) Subsection 606.2.2. Common Supply and Return Air Systems. Delete the entire subsection and replace with the following: "Smoke detectors shall be placed in air distribution systems as required by Chapter 11, Chapter 11, the City of Gaithersburg Fire Safety Code, referencing NFPA 90-A." (36) Subsection 607.5.5. Shaft Enclosures. Exceptions: 2. Replace the phrase "In Group B and R occupancies equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 of the International Building Code, smoke dampers are not required at penetrations of shafts where" with the following: "In buildings, other than Group H occupancies, equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 or 903.3.1.2, smoke dampers are not required at:" (37) Section 609. Add new Section 609. Section 609. EMERGENCY AND STANDBY POWER SYSTEMS. (38) Subsection 609.1. Add new Section [F] 609.1. Subsection. Installation. Emergency and standby power systems required by the City Fire Safety Code or the International Building Code shall be installed in accordance with NFPA 110 and NFPA 111. Existing installations shall be maintained in accordance with the original approval. (39) Subsection 609.1.1. Add new Section [F] 609.1.1. Subsection 609.1.1. Stationary Generators. Stationary emergency and standby power generators required by the International Building Code, or Chapter 11, the City Fire Safety Code, shall be listed in accordance with UL 2200. (40) Subsection 609.2. Add new Subsection [F] 609.2. Subsection 609.2. Standby Power. Where the standby system is a generator set inside a building, the system shall be located in a separate room enclosed with a 2-hour fire barrier constructed in accordance with section 707 or horizontal assemblies constructed in accordance with section 712 of the International Building Code, or both. System supervision with manual start and transfer features shall be provided at the fire command center. (41) Subsection 6092.1. Add New Subsection [F] 6092.1. Subsection 6092.1. Ventilation Air. Ventilation air shall be supplied directly from a source outside the building by an exterior wall opening or from a source outside the building by a 2-hour fire rated air transfer system. (NFPA 110). (42) Subsection 609.2.2. Add new Subsection [F] 609.2.2. Subsection 609.2.2. Discharge Air. Discharge air shall be directed outside the building by an exterior wall opening or to an exterior opening by a 2-hour rated air transfer system. (NFPA 110). (43) Subsection 609.2.3. Add new Subsection [F] 609.2.3. Subsection 609.2.3. Fire Dampers. Fire dampers, shutters or other self-closing devices shall not be permitted in ventilation or discharge air openings or ductwork for standby power systems. (NFPA 110). (44) Subsection 609.2.4. Add new Subsection [F] 609.2.4. Subsection 609.2.4. Motor Operated Dampers. Motor operated dampers, when used, shall be spring operated to open and motor closed. (NFPA 110). (45) Subsection 1001.1. Scope. Add the following sentence at the end of the first sentence, "The provisions of this section are applicable only if not covered by the regulations of WSSC code and/or the State of Maryland Boiler and Pressure Vessel regulations." (46) Roof Screening of Rooftop Mechanical Equipment. Mechanical Equipment Screening shall be provided as delineated above in IMC Section 304.13. MECHANICAL EQUIPMENT SCREENING, and ultimate solution shall be approved by City planning.

(Ord. No. O-9-22, 10-3-22)

Ask a question about Gaithersburg law

Corpus searches the Gaithersburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.