§ 5-23 — Clarifications to the Maryland Accessibility Code—ADAAG/2010
Code of the City of Gaithersburg, Maryland (Codified through Ordinance No. O-08-26, adopted September 8, 2026. (Supp. No. 52)) · Gaithersburg City Code § 5-23
Corpus is an independent public-information project, not the official City of Gaithersburg website. Stable reference: corpuslaw.us/code/85c52b64-23a1-4c32-b62f-0ff4510ebecc
Sec. 5-23. - Clarifications to the Maryland Accessibility Code—ADAAG/2010.
(1) Ambulatory Stalls. Where water closet compartments are installed in a toilet room or bathing room, at least one wheelchair-accessible compartment shall be provided. Where the combined total water closet compartments and urinals installed in a toilet room or bathing room is six or more, at least one ambulatory accessible water closet compartment shall be provided in addition to the wheelchair-accessible compartment. (2) ADA Sidewall Grab Bar Requirements: Sidewall Grab Bars. The accessible stall grab bar requirements are as follows: Grab bars shall be installed on the rear wall and on the sidewall closest to the water closet. These bars shall have a diameter of 1-¼ inches to 2 inches, however, the US Access Board recommends, but does not stipulate, the use of 2 inch bars exclusively, and be mounted to allow 1-½ inches clearance from the inside of the bar to the wall on which they are located. Bars shall be so installed to support a minimum of 250 lbs. of force, applied any direction, and assure any decorative flanges as part of the bar(s) employed are attached properly to the wall with no sharp edges. a. The Side Wall Horizontal Bar shall be 42" minimum in length, leading edge located 12" maximum from the rear wall and extending 54" from the rear wall. b. A vertical grab bar 18" minimum in length shall be mounted with the leading bottom edge of the bar located between 39" and 41" above the floor and with the centerline of the bar located between 39" and 41" from the rear wall. c. The Rear Wall Grab Bar shall be 36" minimum in length, and extend from the centerline of the water closet 12" minimum on the side closest to the sidewall and 24" minimum on the transfer side. Approved alternate recessed sink layouts may shorten the overall length of this bar. (3) Sec. 36.203.9 Employee Work Areas. Amend the paragraph, after enter, and before exit, insert the words "circulate, egress, alarm wiring." (4) Sec. 36.213.2 Toilet Rooms and Bathing Rooms. Amend the section by adding the following to the end of the paragraph, before the exceptions: Changing stations are required in toilet room(s) and the minimum installation requirements are found in the ICC amendments, Section 1204.5 and 1204.6, as applicable. (5) Specific Accessibility Parking Requirements For Electric Vehicles, Public Parking With Electric Vehicle Charging Stations (EVCS). Sec. 36.402 Accessibility for Electric Vehicle Charging Stations (EVCS) Parking. Electric vehicle parking space(s), where scheduled to include a charging station device, shall be provided with an access aisle to accommodate accessibility, and signage indicating that the space is for the exclusive use of electric vehicles. (a) When providing EVCS access, by one or more spaces, at least one space shall be accessible by the inclusion of a 5 ft. wide access aisle, but not mandated to only disabled persons. The space(s) shall be located in close proximity to the building or facility entrance and connected to a barrier-free accessible route of travel. The EVCS space requirement, if then so used by a physically challenged individual, does not have to be a specifically reserved/marked/used space, only accessible for use by a physically challenged individual. It shall be available for use by all persons with no specific signage requirement. (b) Where required by statute to provide an accessible space (with EVCS access), an EVCS space shall be placed next to a dedicated accessible space, where the charging unit can be shared by both spaces, or provided with a separate designated space with a charging station device. (6) Add new section to: Sec. 5-23—Clarifications to the Maryland Accessibility Code—ADAAG/2010. 1109.16 General. Where Electric Vehicle Charging Stations are provided, all charging stations shall be provided in accordance with this section. 1109.16.1 Existing Facilities. Where Electric Vehicle Charging Stations are either added or altered within a facility having existing Electric Vehicle Charging Stations, the requirements this section shall apply only to the newly installed or altered Electric Vehicle Charging Stations. 1109.16.2 Minimum Number. Where Electric Vehicle Charging Stations are provided for public use, the minimum number of accessible Electric Vehicle Charging Stations shall be provided in accordance with Table 1109.16.2. Where new Electric Vehicle Charging Stations are installed in facilities with existing Electric Vehicle Charging Stations, the total number provided in Table 1109.16.2 shall include both existing and new Electric Vehicle Charging Stations. Where an Electric Vehicle Charging Station charger can simultaneously charge more than one vehicle, the number of Electric Vehicle Charging Station chargers provided shall be considered equivalent to the number of electric vehicles that can be simultaneously charged. Not less than 5%, but not fewer than one (1) of all EVCS provided on a site must be accessible. Parking spaces serving Electric Vehicle Charging Stations per this section shall not account for any of the required accessible parking spaces on the site unless specifically provided with accessible identification signage. Exception: 1. Electric Vehicle Charging Stations not available to the general public and intended for use by a designated vehicle or driver shall not be required to comply with this section. Examples include, but are not limited to, charging stations serving public or private fleet vehicles, assigned to an employee, or serving private residences. Table 1109.16.2 Electric Vehicle Charging Stations for Public Use Number of EV Charging Stations Provided | Minimum Number of Adaptable EV Charging Stations Required 1 to 25 | 1 26 to 50 | 2 51 to 75 | 3 76 to 100 | 4 Over 101 | 4, plus 1 for each 300 over 100 1109.16.3 Vehicle Space Size. Parking spaces serving adaptable Electric Vehicle Charging Stations shall be sized as "van accessible", including both the parking space and the accessible aisle serving it. 1109.16.3.1 Van Space. A minimum of one (1) parking space serving an adaptable Electric Vehicle Charging Station shall be sized the same as a van-accessible parking space including both the parking space and the accessible aisle serving it. 1109.16.4 Operable Parts and Related Equipment. Pay terminals, operable parts, graphic displays and other related features shall be accessible. 1109.16.5 ACCESSIBLE ROUTES. Accessible routes shall be provided to serve Electric Vehicle Charging Stations. 1109.16.5.1 Building or Facility. Adaptable Electric Vehicle Charging Stations that serve a building or facility on the same site shall be located along an accessible route providing access to an accessible building entrance. Where Adaptable Electric Vehicle Charging Stations do not serve a building or facility on the same site, they shall be located along an accessible route providing access to the public way. 1109.16.5.2 Charging Stations. Adaptable Electric Vehicle Charging Stations shall be provided with an accessible route between the accessible aisle serving it and all related operable parts and other equipment. When a vehicle is being charged, the accessible route shall not be obstructed by the cable between the vehicle and the charging station. 1109.16.6 Accessible Identification Signs. Adaptable Electric Vehicle Charging Stations shall be identified by the International Symbol of Accessibility. Exception: 1. Where a total of ten or fewer Electric Vehicle Charging Stations are provided, accessible identification signage is not required. (7) Excerpts from ADA, Title III as Referenced in the "Maryland Accessibility Code", Alterations and Disproportionality. Sec. 36.402. Alterations. (a) General. (1) Any alteration to a place of public accommodation or a commercial facility, after January 26, 1992, shall be made so as to ensure that, to the maximum extent feasible, the altered portions of the facility are readily accessible to and usable by individuals with disabilities, including individuals who use wheelchairs. (2) An alteration is deemed to be undertaken after January 26, 1992, if the physical alteration of the property begins after that date. (3) When barriers still exist in a building, any alterations to a primary function area may trigger demand for readily achievable ADA compliance upgrades. Per ADA, the additional amount the entity is required to spend over the amount of the actual construction costs would be 20% max., dedicated to removing any remaining barriers. (4) If the total cost for compliance exceeds the 20 percent threshold, the entity must still make the path of travel accessible to the extent possible without going over 20 percent requirement, giving priority to those elements that provide the greatest degree of access, as outlined under paragraph "Duty to Provide Accessible Features in the Event of Disproportionality". (b) Alteration. For the purposes of this section, an alteration is a change to a place of public accommodation or a commercial facility that affects or could affect the usability of the building or facility or any portion thereof. (1) Alterations include, but are not limited to, remodeling, renovation, rehabilitation, reconstruction, historic restoration, changes or rearrangement in structural parts or elements, and changes or rearrangement in the plan configuration of walls and full-height partitions. Normal maintenance, reroofing, painting or wallpapering, asbestos removal, or changes to mechanical and electrical systems are not alterations unless they affect the usability of the building or facility. (2) If existing elements, spaces, or common areas are altered, then each such altered element, space, or area shall comply with the applicable provisions of appendix A to this part. (c) To the Maximum Extent Feasible. The phrase "to the maximum extent feasible", as used in this section, applies to the occasional case where the nature of an existing facility makes it virtually impossible to comply fully with applicable accessibility standards through a planned alteration. In these circumstances, the alteration shall provide the maximum physical accessibility feasible. Any altered features of the facility that can be made accessible shall be made accessible. If providing accessibility in conformance with this section to individuals with certain disabilities (e.g., those who use wheelchairs) would not be feasible, the facility shall be made accessible to persons with other types of disabilities (e.g., those who use crutches, those who have impaired vision or hearing, or those who have other impairments). (8) Sec. 36.403. Alterations: Path of Travel. (a) General. An alteration that affects or could affect the usability of or access to an area of a facility that contains a primary function shall be made so as to ensure that, to the maximum extent feasible, the path of travel to the altered area and the restrooms, telephones, and drinking fountains serving the altered area, are readily accessible to and usable by individuals with disabilities, including individuals who use wheelchairs, unless the cost and scope of such alterations is disproportionate to the cost of the overall alteration. (b) Primary Function. A "primary function'' is a major activity for which the facility is intended. Areas that contain a primary function include, but are not limited to, the customer services lobby of a bank, the dining area of a cafeteria, the meeting rooms in a conference center, as well as offices and other work areas in which the activities of the public accommodation or other private entity using the facility are carried out. Mechanical rooms, boiler rooms, supply storage rooms, employee lounges or locker rooms, janitorial closets, entrances, corridors, and restrooms are not areas containing a primary function. (c) Alterations to an Area Containing a Primary Function. (1) Alterations that affect the usability of or access to, an area containing a primary function, the altered area and the amenities serving the altered area must be made accessible, unless the costs for these changes are disproportionate. (2) For the purposes of this section, alterations to windows, hardware, controls, electrical outlets, and signage shall not be deemed alterations that affect the usability of or access to an area containing a primary function. (3) Restriping of parking lots is regarded as an alteration and must be brought up to current code requirements establishing ADA access. (d) Landlord/Tenant: If a tenant is making alterations as defined in Sec. 36.402 that would trigger the requirements of this section, those alterations by the tenant in areas that only the tenant occupies do not trigger a path of travel obligation upon the landlord with respect to areas of the facility under the landlord's authority, if those areas are not otherwise being altered. (e) Path of Travel. (1) A "path of travel'' includes a continuous, unobstructed way of pedestrian passage by means of which the altered area may be approached, entered, and exited, and which connects the altered area with an exterior approach (including sidewalks, streets, and parking areas), an entrance to the facility, and other parts of the facility. Accessible route is to the facility front door and must be maintained. (2) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms, and other improved areas; parking access aisles; elevators and lifts; or a combination of these elements. Maximum open gap width between sidewalk panels shall be ½ inch. Accessible route paving material installation shall be firm, stable, and slip resistant. No beveled paving materials shall be used in the accessible path of travel route. Carpeting shall not be installed on ramps. (3) Accessible route and arrival point are a priority regarding the 20% rule, except in historic applications, see disproportionality below. (4) For the purposes of this part, the term ''path of travel'' also includes the restrooms, telephones, and drinking fountains serving the altered area. (f) Disproportionality. (1) Alterations made to provide an accessible path of travel to the altered area will be deemed disproportionate to the overall alteration when the cost exceeds 20% of the cost of the alteration to the primary function area. (2) Costs that may be counted as expenditures required to provide an accessible path of travel may include: (i) Costs associated with providing an accessible entrance and an accessible route to the altered area, for example, the cost of widening doorways or installing ramps; (ii) Costs associated with making restrooms accessible, such as installing grab bars, enlarging toilet stalls, insulating pipes, or installing accessible faucet controls; (iii) Costs associated with providing accessible telephones, such as relocating the telephone to an accessible height, installing amplification devices, or installing a telecommunications device for deaf persons (TDD); (iv) Costs associated with relocating an inaccessible drinking fountain. (g) Duty to Provide Accessible Features in the Event of Disproportionality. (1) When the cost of alterations necessary to make the path of travel to the altered area fully accessible is disproportionate to the cost of the overall alteration, the path of travel shall be made accessible to the extent that it can be made accessible without incurring disproportionate costs. (2) In choosing which accessible elements to provide, priority shall be given to those elements that will provide the greatest access, in the following order: (i) An accessible entrance; (ii) An accessible route to the altered area; (iii) At least one accessible restroom for each sex or a single unisex restroom; (iv) Accessible telephones; (v) Accessible drinking fountains; and (vi) When possible, additional accessible elements such as parking, storage, and alarms. (9) Sec. 36.404.2.9. Door and Gate Opening Force. Amend the section by adding the following to the end of the numbered definitions. 3. Exterior doors: 15 pounds (66.72 N) maximum. Hardware operation by a rotational motion: 28 inch-pound (3.16 N) maximum. (10) Sec. 36.604.8.1.2. Doors. Amend the section by adding the following to the end of the paragraph. Toilet compartment doors shall have ADA compliant thumb-turn or sliding latching hardware. (11) Sec. 36.606.5. Exposed Pipes and Surfaces. Amend the section by adding a second sentence. In a gang facility, all piping, whether or not specifically designated for the physically challenged, shall be insulated. (12) ADA Requirement Waivers. In some instances, the Maryland ADA requirements exceed the current Federal ADA 2010 requirements. Only those requirements (set by the state of Maryland) are subject to waiver request, as Federal requirements are absolute and are not subject to waiver. Persons interested in waiver applications must apply to the Building Codes Administrator, with the Maryland State Department of Labor, with all defining documents for waiver request consideration. The term "grandfather" does not apply to ADA requirements
(Ord. No. O-9-22, 10-3-22)
Ask a question about Gaithersburg law
Corpus searches the Gaithersburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.
