§ 5-3 — Same—Modifications to the International Building Code (IBC) (2021)

Code of the City of Gaithersburg, Maryland (Codified through Ordinance No. O-08-26, adopted September 8, 2026. (Supp. No. 52)) · Gaithersburg City Code § 5-3

Corpus is an independent public-information project, not the official City of Gaithersburg website. Stable reference: corpuslaw.us/code/cd3446a8-7e56-4ad4-9e62-27bfecdc210c

Sec. 5-3. - Same—Modifications to the International Building Code (IBC) (2021).

The International Building Code (2021) is modified as follows: (1) General. Whenever the words "name of jurisdiction" or "authority having jurisdiction" appear in this code, insert the words "the City of Gaithersburg". (2) General. Whenever the words "building official" appear in this code, they shall be deemed to represent the city manager or designee. (3) General. Whenever the words "department" or "department of building safety" appear in this code, they shall be deemed to represent the City of Gaithersburg, Department of Planning and Code Administration, Permits and Inspections Division. (4) General. Delete all references to "the ICC Electrical Code" in this (IBC) or any other so named International Code adopted by this ordinance, and replace with "the City of Gaithersburg Code, Chapter 7, Electricity." (5) Subsection 101.2. Scope. To the Exception, add the following: Exception. Existing buildings, as defined by the Maryland Building Rehabilitation Code, undergoing repair, alterations or additions and change of occupancy shall be permitted to comply with the Maryland Building Rehabilitation Code. (6) Subsection 101.2.2. Add new Subsection 101.2.2. to read as follows: 101.2.2. City sponsored construction. "All construction projects financed, in part or in full, by the City of Gaithersburg, shall conform to all pertinent provisions of this code and all other codes adopted by the City of Gaithersburg to regulate safety in the built environment. This includes obtaining all permits and inspections that would be required of any private sector work. No fees will be charged for City sponsored construction." (7) Subsection 101.3.1. Add new Subsection 101.3.1. to read as follows: 101.3.1. Permits, Approvals, and Inspections: The purpose of issuing permits, reviewing and approving plans, and conducting inspections is to protect and promote public safety, health, and welfare. These activities are purely governmental in nature, shall be conducted solely for the purpose of public benefit, and are not to be construed as providing any warranty by the City, as to design or construction, including methods and materials, to anyone. Nothing in this ordinance should be construed as creating any legal duty to the owner, operator, or user of any premises, by the City of Gaithersburg." (8) Subsection 101.4.1. Gas. Delete the phrase "International Fuel Gas Code" in the first sentence and insert the phrase "Regulations Governing the Installation of Plumbing, Gasfitting and Sewer Cleaning in the Washington Suburban Sanitary District," as published by The Washington Suburban Sanitary Commission (WSSC). Add a new sentence at the end of the subsection to read, "Fuel-gas piping systems, fuel gas appliances, gaseous hydrogen systems and related accessories are regulated under the authority of Washington Suburban Sanitary Commission (WSSC)". "The Provisions of the International Fuel Gas Code shall apply only in instances that are not governed by WSSC regulations." (9) Subsection 101.4.3. Plumbing. Delete all references to the phrase "International Plumbing Code" in the first sentence and insert the phrase "Plumbing and Gasfitting Regulations of the Washington Suburban Sanitary District." In the last sentence, delete the phrase "International Private Sewage Disposal Code" and replace with the phrase, "the Montgomery County Department of Health." (10) Subsection 101.4.4. Property maintenance. After the phrase "International Property Maintenance Code", add the following phrase: "as adopted by the City of Gaithersburg, City Code, Chapter 17AA." (11) Subsection 101.4.5. Fire prevention. Delete all references to the phrase: "International Fire Code" and replace it with the following phrase "as adopted by the City of Gaithersburg, City Code." (12) Subsection 101.4.7. Existing buildings. Following the phrase "The provisions of" and before the phrase "the International Existing Building Code" add "the Maryland Building Rehabilitation Code/". The state of Maryland adopts the IEBC as its rehab/existing building code and applies this code to buildings of all types over one (1) year old. (13) Subsection 101.4.8. Add new Subsection 101.4.8, Electricity, to read as follows: 101.4.8. Electricity. Any and all references in this code to electricity or the code governing electricity shall represent "Chapter 7, the City of Gaithersburg Electrical Code." (14) Subsection 101.4.9. Add new Subsection 101.4.9. Accessibility to read as follows: 101.4.9. Accessibility. "Whenever the IBC, or any of the ICC Series Codes, references the IBC Chapter 11 or ANSI A 117.1., Add the Maryland Accessibility Code- ADAAG/2010", which takes first precedence on the applicable reference list of codes sequence." (15) Subsection 102.1. General. At the end of Subsection 102.1, add the following: "Exception. Alternative features which are accepted or approved in writing by the Building Official shall be considered as conforming with all codes, provided that the overall level of health, safety, and welfare of the building/occupancy is not diminished." (16) Subsection 102.6. Existing structures. Delete all references to the phrase: "the International Property Maintenance Code or the International Fire Code," and replace it with "or any other applicable provision of the City of Gaithersburg Code." (17) Subsection 102.6. Existing structures. Add the following paragraph to the end of the section. Subsection 102.6.3 Alternative Materials and Methods/Designs. Alternative materials and methods/designs to the established building code requirements may be allowed if the submitted material parameters comply with the 2021 edition of the International Code Council Performance Code @ (ICCPC) and the solution addresses specific public health and safety concerns not otherwise defined in the adopted codes, subject to City Planning and Code Administration approval. (18) Section 103. Delete Section 103.1 and substitute the following: 103.1 Enforcement Agency. The City of Gaithersburg Planning and Code Administration is responsible for enforcing the provisions of this code. The director of the City of Gaithersburg Planning and Code Administration or the director's authorized designee shall be known as the City Building Official. (19) Subsection 104.4. Inspections. Add the following sentence at the end of the paragraph as follows: All field inspections shall comply with the inspections provisions of the City Code of Ordinances, Chapter 5, Article 1, Section 5-3, the 2021 International Building Code (IBC), and all applicable City code amendments. Subsection 104.4.1. Third Party Inspections. Add new Subsections 104.4.1, and 104.4.2., to read as follows: 104.4.1. Applicability: The Certified (Third-Party) Inspections Program is the City of Gaithersburg, MD's policy for "third-party" inspections of commercial and residential projects requiring construction or maintenance inspections by Inspections staff. This program is pursuant to the Code of the City of Gaithersburg, MD., and the International Building Code, and also applies to projects using the International Existing Building Code. Questions may be directed to Inspections staff, (301) 258-6330. Exception. This program does not apply to construction under the Special Inspections Program, nor to new residential construction of Groups R-3 or R-4 within the scope of the International Residential Code, nor to fire detection, fire protection or fire suppression systems, nor to inspections by other City agencies. The Certified Inspections Program offers property owners and construction contractors of commercial and residential construction projects the option for certain construction inspections to be performed and certified by private sector "third-party" engineers and inspectors, to the extent specified below, when approved in advance by the City of Gaithersburg. The Inspections staff will accept, review and approve such certified inspections, in lieu of inspections by Inspections staff, except in situations where there is specific cause that a particular report shall be rejected. The Inspections staff will monitor the quality of the certified inspections. The Inspections staff will continue to provide full support to inspection requests for projects not involved in this certified inspections program. Private sector "third-party" inspection firms and personnel shall be employed directly by the project owner, shall be independent of the project architect or engineering design firm or contractors performing the work, and shall have no personal financial interest in the project. The building official, on a project -by-project basis, shall approve both the inspection firm and its personnel prior to commencement of construction. 104.4.2. Personnel Credentials. Inspections shall be conducted under the direct supervision of, and certified by, a Registered Design Professional, licensed in the State of Maryland. The Registered Design Professional and Registered Design Professional's field inspector personnel shall all possess appropriate State of Maryland or International Code Council, Inc. (ICC) inspector credentials. An inspector or Registered Design Professional approving work that is not in conformance with the City-approved plans and the Code of the City of Gaithersburg, MD. may lose City approval to perform future inspections. (20) Subsection 105.1. Required. Add the following: A separate permit is required for each legal address. A separate permit is required for each separate building at a legal address. (21) Subsection 105.2. Work exempt from permit. Delete the following itemized provisions of the subsection: Building: 1., 2., 4., 6., 7. - partial, only for - cabinets and countertops that do not interfere with egress, 9., 12., and 13. - partial, only for items that do not interfere with egress. Also delete in their entirety the portions of this subsection regarding Gas-Fitting and Plumbing (as regulated by WSSC). (22) Subsection 109.1. Payment of fees. Add a second sentence to read, "Required fees shall be paid for each separate permit application before the approved permit shall be released." (23) Subsection 109.2. Schedule of permit fees. Edit as follows: Delete the phrase "the applicable governing authority" and replace it with "the Mayor and City Council." (24) Subsection 109.3. Building permit evaluations. Delete. (25) Subsection 109.5.1. Reinspection Fees. Add new Subsection 109.5.1 as follows: 109.5.1 Reinspection Fees. A reinspection fee shall be charged for each reinspection if the work has to be reinspected because: a) The work was not ready for inspection at the pre-arranged time for inspection; b) The inspector did not have access to the work at the prearranged time for inspection; c) The inspector had to return more than once to inspect a correction of the same violation of this code; or d) The inspector discovers flagrant non-compliance issues during a requested inspection, including but not limited to: 1. Cut or broken trusses or joists; 2. Missing load bearing studs; or 3. The omission of fire stopping. (26) Section R110.3.1. Footing and Foundation Inspection. After the first paragraph, insert the following: A. As-Built Foundation Survey (Wall Check). A wall check survey is required before the foundation wall reaches a height of 1 foot (305 mm) above the footer, or, in the case of other vertical construction, when a template or form is located and noted. The City may require up to three wall checks depending on the design of the structure: below grade at footer, near grade, and final grade. Surveys, wall examinations and reports, drawings and field notes, shall be filed with the City. Surveying practices should comply with standards set forth in the current practices. Wall check surveys shall be performed by a Registered Land Surveyor. Authorization to continue construction of any building or other structure beyond construction of the foundation shall not be issued until a wall report has been prepared and submitted to the City. No inspections will be scheduled, nor will final inspection reports be accepted, until the wall check has been reviewed and approved. The wall report shall confirm that the location and elevation of the building or other structure is in conformance with the approved plans and the provisions of the construction codes and any other applicable City regulations. (27) Subsection 110.3.12. Final inspection. Insert before the first sentence: "The final inspection must be requested and approved before a building (or portion thereof) is used or occupied in any way, including moving in any furniture, shelving stock, equipment, files, and similar items unless specific, written permission is obtained from the building official. (E.G. OK to stock.)" (28) Subsection 110.5. Inspection requests. Add the following to the end of the paragraph: Any overtime inspection request(s) must be made a minimum of 48 hours in advance. (29) Subsection 111.1. Change of occupancy. After the phrase "A building or structure", add the phrase: "or portion thereof." (30) Subsection 111.2. Certificate issued. Delete all text in this subsection after the phrase "shall issue a certificate of occupancy" and replace it with the following phrase "as per department policy." (31) Section 113. General. Delete Subsections 113.1, 113.2 and 113.3, and 113.4, and add new Subsection 113.1 as follows: "Subsection 113.1. Means of Appeals. Any decision or order of the City Manager or designee under this chapter may be appealed within 17 days of the date of such decision or order to the City Board of Appeals. Any decision of the City Board of Appeals may be appealed to the Circuit Court within 30 days of the date of the Board's written decision. The Maryland Rules of Procedure shall govern such appeals. Any decision of the Circuit Court may be appealed to the appellate courts of this state." (32) Subsection 114.4. Violation penalties. Delete the phrase "subject to penalties as described by law," and replace with: "guilty of a municipal infraction, enforceable and punishable by a fine and/or penalty as established by the Mayor and City Council pursuant to Sections 1-9 through 1-11 of the City Code. Each day that a violation exists shall be deemed a separate offense." "In addition thereto, the City may institute injunctive, mandamus, or any other appropriate action or proceedings at law or equity for enforcement of this Chapter, or to correct violations of this Chapter, and any court of competent jurisdiction shall have the authority to issue restraining orders, temporary or permanent injunctions or mandamus or other appropriate form of remedy or relief." (33) Subsection 115.5. Unlawful continuance. Insert the following: Any person who shall refuse to leave, chooses to interfere with the evacuation of other occupants, or continue any operation after having been given an evacuation order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be deemed guilty of a municipal infraction, and shall be subject to a fine as provided in the city schedule of fees. "In addition thereto, the City may institute injunctive, mandamus, or any other appropriate action or proceedings at law or equity for enforcement of this Chapter, or to correct violations of this Chapter, and any court of competent jurisdiction shall have the authority to issue restraining orders, temporary or permanent injunctions or mandamus or other appropriate form of remedy or relief." (34) Add new Subsection 115.6 Withholding of inspections and permits, as follows: 115.6 Withholding of Inspections and Permits. If the building official finds that an owner or person responsible is in violation of a provision of this code, this subtitle, or any regulation that implements this code in connection with the construction, maintenance, alteration, or repair of any building, equipment, or land within the City, the building official may refuse to grant an inspection or permit to the contractor, developer, owner, or other person responsible until all violations have been corrected and all fees and fines have been paid. (35) Add new Section 117 Emergency Measures, as follows: Section 117 Emergency Measures. 117.1 Imminent Danger. Whenever the building official determines that there is an emergency or imminent danger of failure or collapse of a building, structure, or any part of a building or structure that endangers life, or when any building, structure, or part of a building or structure has fallen and life is endangered by the occupation of the building or structure, the building official may order an occupant to vacate the building or structure. The building official shall post a notice at each entrance to the building or structure. The notice shall state as follows: "this structure is unsafe and its occupancy has been prohibited by the building official." Except for the purpose of making a required repair or demolishing the building or structure, a person shall not enter the building or structure. 117.2 Temporary Safeguards. Whenever the building official determines that there is imminent danger due to an unsafe condition, the building official may cause the necessary work to be done to make the building or structure temporarily safe, whether or not the legal procedure as set forth in this code has been instituted. 117.3 Closing Streets and Buildings. If necessary for public safety, the building official may take any of the following actions: a) Temporarily close a building or structure; b) Close or order the jurisdiction to close a sidewalk, street, public way, or place adjacent to an unsafe building or structure; or c) Prohibit the use of a sidewalk, street, public way, or place adjacent to an unsafe building or structure. 117.4. Demolition of Structures. Whenever the building official determines that there is imminent danger due to an unsafe structure, the building official may cause the structure to be demolished in accordance with Section 116 of this code. 117.5 Emergency Repairs. For the purpose of this section, the building official may employ the necessary labor and materials to perform the required work as expeditiously as possible. 117.6 Cost of Emergency Repairs. Costs incurred in the performance of emergency work may be paid from the treasury of the jurisdiction. The City shall institute appropriate action to seek reimbursement against the owner of the premises where the unsafe building or structure is or was located for the cost of the repairs or actions necessary to make the premises safe. 117.7 Unsafe Equipment. Whenever the building official determines that equipment is unsafe, the equipment shall not be operated after the date stated in the notice unless the required repairs, replacement, or changes have been made and the equipment has been approved or unless the building official has agreed, in writing, to an extension of time to make the required repairs, replacement, or changes. 117.7.1 Authority to Seal Equipment. In the case of an emergency, the building official may immediately seal out of service any unsafe device or equipment regulated by this code. 117.7.2 Unlawful to Remove Seal. Any device or equipment sealed out of service by the building official shall be plainly identified in an approved manner. With exception by the building official, the identification shall not be tampered with, defaced, or removed. The identification shall indicate the reason for the sealing of the equipment. (36) Add new Section 118 Demolition of Structures as follows: Section 118 Demolition of Structures. 118.1 Service Connections. Before a structure is demolished or removed, the owner or agent shall notify all utilities having service connections within the structure including, but not limited to, water, electric, gas, or sewer. A permit to demolish or remove a structure shall not be issued until a release is obtained from the utilities and received by the City. The release shall state that the utilities respective service connections and appurtenant equipment, such as meters and regulators, have been removed, sealed, or plugged in a safe manner. A complete set of photos (PDF) of all building elevations shall be submitted to the City to be made part of the record file. All requested information must be received by the City before the permit will be approved. 118.2 Notice to Adjoining Owners. As part of the permit requirements to remove or demolish a building or structure, written notice must be given by the applicant to the owners of adjoining lots and to the owners of wired or other facilities that may need to be temporarily removed due to the proposed work. 118.3 Lot Regulation. Whenever a structure is demolished or removed, the premises shall be maintained free from all unsafe or hazardous conditions by the proper regulation of the lot, restoration of established grades, and the erection of the necessary retaining walls and fences in accordance with the provisions of Chapter 33 of this code. 118.4 Found Hazardous Materials. Hazardous materials identified by building survey or found during the course of building demolition preparation, whether solid, liquid or gaseous, and/or pressurized cylinders shall be removed by certified personnel in strict accordance with the Maryland Department of the Environment, the Washington Suburban Sanitary Commission and the U.S. Environmental Protection Agency requirements. (37) Chapter 2. Definitions. Section 202. Definitions. Add to the following term: "Accessible Route." Add the following at the end of the 1st sentence: "The route shall include the following features; site arrival points, walking surfaces, door and doorways, ramps and curb ramps, elevators, and platform lifts. The accessible route shall also include an accessible means of egress, defined by the IBC, as a "continuous and unobstructed way of egress travel from any point in a building or facility that provides an accessible route to an area of refuge, a horizontal exit, or a public way." (38) Chapter 2. DEFINITIONS. Section 202. DEFINITIONS. Add the following term: "AUTHORITY HAVING JURISDICTION. (AHJ)." An organization, office, or individual responsible for enforcing the requirements of a code or standard, or for approving equipment, materials, an installation, or procedure. Further defined under 2021 IBC Section 104, Duties and Powers of Building Official. Authority having jurisdiction is the City of Gaithersburg within the established city limits. (39) Chapter 2. DEFINITIONS. Section 202. DEFINITIONS. Add the following term: "BABY CHANGING TABLE." A table or other device that is safe and sanitary for changing the diaper of a child age 3 or under. (40) Chapter 2. DEFINITIONS. Section 202. DEFINITIONS. Add the following term: "CERTIFY." Use of the word "certify" or "certification" constitutes an expression of professional opinion regarding those facts or findings, which are the subject of the certification. (41) Chapter 2. DEFINITIONS. Section 202. DEFINITIONS. Add the following term: "CLIMBABLE." To go up or ascend, by using the hands and feet, or feet only, i.e. "to climb up a ladder". Definition of term as related to railings, fences, gates, and other devices provided to prevent unrestricted area access to areas typically requiring restriction due to personal safety reasons. (42) Chapter 2. Definitions. Section 202. Definitions. Add the following term: "Design Rain Loads." Each portion of a roof shall be designed to sustain the load of rainwater that will accumulate on it if the primary drainage system for that portion is blocked plus the uniform load caused by water that rises above the inlet of the secondary drainage system at its design flow. The design rainfall shall be based on the 100-year hourly rainfall rate indicated in Figure 1611.1 or on other rainfall rates as determined from approved local weather data. (43) Chapter 2. DEFINITIONS. Section 202. DEFINITIONS. Add the following term: "ELECTRIC VEHICLE CHARGING STATION. Change the existing definition to read: One or more dedicated parking spaces (signed/placarded or not) that are provided to accommodate charging of electric motor vehicles. (44) Chapter 2. Definitions. Section 202. Definitions. Add the following term: "Festival Seating." A form of audience/spectator accommodation in which no seating, other than a floor or finished ground level, is provided for the audience/spectators gather to observe a performance. Festival seating describes situations in assembly occupancies where live entertainment events are held that are expected to result in overcrowding and high audience density that can compromise public safety. It is not the intent to apply the term festival seating to exhibitions; sports events; dances; conventions; and bona fide political, religious, and educational events. Assembly occupancies with 15 sq. ft. or more per person will not be considered festival seating. (45) Chapter 2. DEFINITIONS. Section 202. DEFINITIONS. Add the following term: "FINAL GRADING REPORT." A grading report stamped and signed by a registered design professional certifying that the building pad was constructed in conformance with the recommendations set forth in the geotechnical report. This report contains explicit information and data that verifies compliance with the geotechnical report of record including any approved supplements or addendums. (46) Chapter 2. DEFINITIONS. Section 202. DEFINITIONS. FOSTER CARE FACILITIES. Change 2½ to "2." (47) Chapter 2. DEFINITIONS. Section 202. DEFINITIONS. Add the following term: "GEOTECHNICAL REPORT (SOILS REPORT)." Data and engineering recommendations resulting from site exploration, which evaluates the soil conditions and general site characteristics and suitability of the site for the proposed construction. A registered design professional shall prepare and seal the report. (48) Chapter 2. DEFINITIONS. Section 202. DEFINITIONS. Add the following term: "LEVEL 2 FINISH." Drywall is typically required as part of a fire separation system. As part of that system, a joint compound is applied over all fastener heads and beads. Joint compound applied over the body of the tape at the time of tape embedment shall be considered a separate coat of joint compound and shall satisfy the conditions of this level. The surface is left free of excess joint compound. Ridges and tool marks are acceptable for a Level 2 finish in areas where the final surface appearance is not of concern. (49) Chapter 2. DEFINITIONS. Section 202. DEFINITIONS. Add the following term: "PHASING PLAN." If a space is scheduled to remain open and occupied while under renovation, a phasing plan will then be required (with City approval prior to commencement of work) detailing the proposed construction zone separation methods and the designated exiting path for each activity (section/quadrant) phase of the proposed operation(s). Provide a narrative description, proposed schedule, and a practical construction phasing plan document outlining and defining the work areas, indicating exiting path(s) and separation(s), with defined exiting length dimensions, as the work is scheduled to be accomplished while the building is occupied, that keeps the occupancy accessible and protects the safety and health of both the patrons and employee isolation from the construction activities, and provides a code-conforming egress path. A pre-construction meeting must be held prior to the start of construction. The City requires a solid barrier between construction areas and occupied areas, unless otherwise approved by the building official or fire marshal. (50) Chapter 2. DEFINITIONS. Section 202. DEFINITIONS. Add the following term: "RECENT ADDITIONS." Recent building addition shall mean any walled and roofed expansion, structural modification or alteration that results in a plan layout change, or an increase in the habitable floor area or height of the building served, including, but not limited to, the modification of an attic, floor space, basement or garage space into useable/habitable space or the addition of dormers, deck or porch, that have been identified by the jurisdiction as newly created since the building information record and valid certificate of occupancy was established and recorded. (51) Chapter 2. DEFINITIONS. Section 202. DEFINITIONS. Add the following term: "REFUSAL." Refusal while advancing an exploration is recognized as defined by ASTM D 1586. (52) Chapter 2. DEFINITIONS. Section 202. DEFINITIONS. Add the following term: "SHADE STRUCTURE." A structure with not less than 50 percent of its perimeter wall area unenclosed, has no interior partitions, and provides solar or weather protection for uses accessory to a building of any occupancy. Shade structures shall not apply to cabanas, canopies, roof structures over vehicle drive-through lanes (porte-cocheres), parking facilities, playground structures, or industrial uses. (53) Chapter 2. DEFINITIONS. Section 202. DEFINITIONS. Add the following term: "STRUCTURAL/GEOTECHNICAL OBSERVATION." The visual observation of the structural system encompassing the structure, foundation elements and the bearing or supporting soils of the foundation elements by a registered design professional for general conformance to the approved construction documents. Structural observation does not include or waive the responsibility for the inspection required by Section 110. (54) Chapter 2. DEFINITIONS. Section 202. DEFINITIONS. Add the following term: "SWIMMING POOLS." Change depth measurement from 24" (610 mm) to 18" (457 mm). This regulation shall also apply to fountains and any other building or site water feature. (55) Subsection 303.1.2. Small Assembly Spaces. Add at the end of the first sentence. "Reference NFPA Life Safety Code 101, Section 7.3.1.2 Occupant Load Factor, which is the more stringent code application for these specifically identified spaces." These spaces may also be acknowledged as collaboration rooms (smaller group activities by people who collectively otherwise occupy the open office spaces). NFPA LSC 101 considers occupant net area loads in a single space to be assembly and not a business occupancy. (56) Subsection 305.1. Educational Group E. Delete the phrase "at any one time" and replace with "for 4 or more hours per day or more than 12 hours per week." (57) Subsection 305.2. Group E, day care facilities. Change "2½" to "2." (58) Subsection 305.2.2. Five or fewer children. In both instances, change "Five" to "Eight." (59) Subsection 305.2.3. Five or fewer children in a dwelling unit. Change "Five" to "Eight." (60) Subsection 308.2.3. Six to 16 persons receiving custodial care. Change "Six" to "Nine." (61) Subsection 308.2.4. Five or fewer persons receiving custodial care. In both instances, change the word "five" to "eight" . (62) Subsection 308.3.2. Five or fewer persons receiving medical care. Change "Five" to "Eight". (63) Subsection 308.5. Institutional Group I-4, daycare facilities. Change "five" persons to "eight" persons. (64) Subsection 308.5.1. Classification as Group E. Change "2½" to "2". (65) Subsection 308.5.3. Five or fewer persons receiving care. Change "Five" to "Eight". (66) Subsection 308.5.4. Five or fewer persons receiving care in a dwelling unit. Change "Five" to "Eight". (67) Subsection 310.4. Residential Group R-3. After the description for R-3 occupancies, add the following: "Exceptions: 1. A family day care home: a dwelling in which child day care services are provided: a) in the home where the registrant is the provider and a resident, or where the registrant is not a resident, but more than half of the children cared for are residents; b) for not more than eight children, including the children of the provider, who are less than six years of age, and; c) where staffing complies with state and local regulations, but no more than two non-resident staff members are on site at any time, may be classified as Group R-3, or as a one or two-family dwelling conforming to the IRC." 2. A group day care home: a dwelling in which child day care services are provided: a) in the home where the licensee is the provider and a resident; b) for nine to 12 children, including the children of the provider, and; c) where staffing complies with state and local regulations, but no more than three non-resident staff members are on site at any time, may be classified as Group R-3, or as a one- or two-family dwelling conforming to the IRC." (68) Subsection 310.4.1. Care facilities within a dwelling. Change "Five" to "Eight". (69) Subsection 310.5. Residential Group R-4. Change "Five" to "Eight". (70) Subsection 403.2.1.2. Shaft enclosures. Delete in entirety. (71) Subsection 403.4.5. Emergency responder radio coverage. Delete the phrase "Section 510 of the International Fire Code" and replace with "Chapter 11, the City of Gaithersburg Fire Safety Code." (72) Subsection 406.3.3.1 Carport separation. Amend Section 406.3.3 to add code condition 2, to read as follows: 2. When a Group B, F, M, R, or S occupancy structure and a noncombustible carport are located on the same property with a minimum separation of ten feet (3048 mm) between the structure and the carport, as measured from the roof edges, exterior wall and opening protection are not required for either structure. (73) Subsection 410.2.4 Proscenium wall. Amend Section 410.2.4 to add an exception, to read as follows: Exception: Where a stage is located in a building of Type I construction, the proscenium wall is permitted to extend continuously from a minimum 2-hour fire-resistance-rated floor slab of the space containing the stage to the roof or a minimum 2-hour fire-resistance-rated floor deck above. This exception shall not apply to buildings of Type IB construction in which the minimum fire-resistance ratings of the building elements in Table 601 have been reduced in accordance with Section 403.2.1.1. (74) Subsection 411.5 Puzzle/Escape Room Exiting. Delete Item #3 and substitute the following: 3. All exits and exit access doors from each puzzle/escape room shall be open and readily available upon activation by the automatic fire alarm system, automatic sprinkler system, a manual control at a constantly attended location and shall have a readily accessible control located inside each puzzle/escape room. (75) Add Subsection 420.12 Visual Access. Add Subsection 420.12 to read as follows: 420.12 Visual access. The primary entrance door of individual units in motels, hotels, apartment houses, condominiums, and similar properties shall contain a means to allow the occupant to visually identify a visitor without opening the unit entry door. (76) Chapter 4. Add new Section 429. RESIDENTIAL OCCUPANCIES. Add new Subsection 429.1. Applicability. 429.1. Applicability. All R occupancies shall have appropriate radon control features prescribed in Appendix F in the International Residential Code, 2021 edition. Appendix F. Section AF103.9 Vent Pipe Identification. Following the last sentence, add "In addition to the labeling requirement above, each designated radon pipe extending vertically through the roof shall be spray painted in a contrasting color not typically associated with plumbing identity colors (ASME A13.1-2020 or OSHA 29 CFR 1910.144, 1910.145) to avoid being mistaken, when under construction or future renovation efforts, as a plumbing waste stack. (77) Reserved. (78) Reserved. (79) Add new Section 430 Beverage Dispensing Applications as follows: Section 430 Beverage Dispensing Applications. 430. Insulated Liquid Carbon Dioxide Systems Used In Beverage Dispensing Applications. Insulated liquid carbon dioxide systems with more than 100 pounds (45.4 kg) of carbon dioxide used in beverage dispensing applications shall comply with the International Mechanical Code, the City of Gaithersburg Fire Code, and this section. 429.1 Ventilation. Where insulated liquid carbon dioxide storage tanks, cylinders, piping, and equipment are located indoors, rooms or areas containing storage tanks, cylinders, piping and equipment, and other areas where a leak of carbon dioxide is expected to accumulate, shall be provided with mechanical ventilation in accordance with the International Mechanical Code. The exhaust system shall be designed to provide air movement across all portions of the floor or room to prevent the accumulation of vapors and maintain the room containing carbon dioxide at a negative pressure in relation to the surrounding area. Exhaust shall be taken from a point within 12 inches (305 mm) of the floor. Mechanical ventilation shall be at a rate of not less than 1 cubic foot per minute per square foot [0.00508 m3/(s × m2)] of floor area over the storage area and shall operate continuously unless alternative designs are approved. A manual shutoff control shall be provided outside of the room in a position adjacent to the access door to the room or in an approved location. The switch shall be a break-glass or other approved type and shall be labeled: "VENTILATION SYSTEM EMERGENCY SHUTOFF." Exception: A gas detection system complying with Section 430.2 shall be permitted in lieu of mechanical ventilation. 429.2 Gas Detection System. Where ventilation is not provided in accordance with Section 429.1, a gas detection system shall be provided in rooms or indoor areas and in below-grade outdoor locations with insulated carbon dioxide systems. Carbon dioxide sensors shall be provided within 12 inches (305 mm) of the floor in the area where the gas is expected to accumulate or other approved locations. The system shall be designed as follows: 1. Activates an audible and visible supervisory alarm at a normally attended location upon detection of a carbon dioxide concentration of 5,000 ppm (9,000 mg/m3). 2. Activates an audible and visible alarm within the room or immediate area where the system is installed upon detection of a carbon dioxide concentration of 30,000 ppm (54,000 mg/m3). (80) Subsection 501.2. Address Identification. Delete the text and replace with the following: "All buildings in the City shall display their address numbers in accordance with the regulations set forth in the Fire Code, Chapter 11, City of Gaithersburg Code." The street address number shall be displayed and be plainly visible and legible from the public street or road fronting the property on which any building is being constructed or remodeled. (81) Amend Subsection 503.1.4. Occupied Roofs. Add the following sentence before the first sentence: "Applicability. The provisions of the following sections shall apply to all parts of buildings and structures that contain any occupancies located on the roof area of the building or structure." (82) Amend Subsection 503.1.4.1 Enclosures over occupied roof areas. After the first sentence, add "Coverings above or around occupants on an occupied rooftop. A rooftop equipped with a horizontal or vertical covering or coverings, including weather protection, such as a roof or a tent or membrane structure that exceeds the limitations of Chapter 24 (Flammable Finishes) of the Fire Code shall be considered an additional story and shall comply with the construction and occupancy requirements of the City Code as a floor." (83) Amend Subsection 503.1.4.1 Exceptions, as follows: Identify the current exception as 1., then add: 2. Small roof coverings may be approved for weather protection of restrooms and beverage preparation areas such as bars without requiring the rooftop to comply with all of the requirements of this code for a story or floor. Such coverings shall comply with the Building Code as to construction materials and fire resistance. The area of such coverings shall be limited to the minimum area required to comply with sanitation and health safety regulations. 3. An open noncombustible trellis or similar overhead shading device complying with the structural requirements of this code shall not be considered as a covering or roof provided that the trellis or shade has an evenly distributed net free open area of 50 percent or greater. (84) Add new Subsection 503.1.4.2 to read as follows: 503.1.4.2. Construction Requirements. Roofs approved for rooftop occupancy shall have a minimum fire resistance of one-hour or the fire resistance required for the building, whichever is greater. Occupied roofs shall be treated as a story for the following construction related purposes: 1. For determining the required construction type and minimum fire resistance rating for the roof structure. 2. For calculating occupant load and building height as they relate to exiting requirements of Chapter 10 and thresholds for fire safety features required by Sections 903 (Automatic Sprinkler Systems), Section 905 (Standpipe Systems), and 907 (Fire Alarm and Detection Systems). 3. Minimum uniformly distributed and concentrated loads for occupied roofs shall be provided for as enumerated in IBC Table 1607.1. Residential occupancies constructed under the commercial code shall be treated similarly. Exception: The occupant load of an occupied roof that complies with this section shall not contribute to the occupant load of the fire area below for the purposes of requiring automatic sprinkler and/or fire alarm protection provided that: A. All openings from below are protected with fire resistive assemblies, and B. The occupied roof has code compliant exits independent of the building or buildings below. C. For the location and installation of toilet facilities. (85) Add new Subsection 503.1.4.3 to read as follows: 503.1.4.3. Fall Protection. Occupied rooftops shall be provided with guards compliant with Section 1013 (Guards). (86) Add new Subsection 503.1.4.4 to read as follows: 503.1.4.4. Interstitial Spaces. When decks or other walking surfaces are constructed above a roof to facilitate rooftop occupancy, the space between the roof/ceiling assembly and the deck or surface shall be constructed in a manner that precludes the accumulation of material between the roof/ceiling assembly and the deck or walking surface and that prevents the introduction of ignition sources to the space. (87) Add new Section 507.14 to read as follows: 507.14 Noncombustible Carports. Noncombustible carports may be of unlimited area when they are open on all sides, not over twelve feet (3658 mm) in height, and located a minimum of 5 feet (1524 mm) from any property line or assumed property line, measured from the roof edge. (88) Subsection 510.2. Horizontal Building Separation Allowance. Amend code condition 6 by deleting the phrase "grade plane" and replacing it with "the lowest level of fire department access." Also, add code condition 7 as follows: 7. For the purposes of determining the number of stories above grade, a story above the 3-hour horizontal assembly shall be considered a story above grade regardless of the location of the average grade plane. (89) Amend Chapter 7 Fire and Smoke Protection Features. Section 701.1 Scope. After the first sentence, add the following sentences: Provide a separate detail sheet, within the plan set, clearly identifying location and the extent of all listed fire-rated assemblies, separations and fire stops on the floor plans, building sections, and details including the following requirements: a. Construction assemblies of both vertical and/or horizontal separations are required to meet the designated fire-resistance rating(s). b. Floor/ceiling and wall assemblies shall extend to and be tight against exterior walls. Wall assemblies shall extend from foundation up to underside of roof sheathing. c. Where floor assemblies are required to be fire-resistance rated, supporting construction (walls, beams, posts) shall have an equal or greater fire-resistance rating. d. Penetrations (including electrical, recessed lights & mechanical ductwork) located within fire-rated assemblies shall comply with specific requirements. Fire stops, blocks, and devices shall be a tested and certified design for construction joints, sound isolation, horizontal and vertical pipe through-penetrations, membrane penetrations, mechanical service and electrical service penetrations, and building perimeter fire stops shall all be referenced, including approval agency listing, assembly rating, and the manufacturer's installation instructions for each firestop/separation assembly and shall be indicated on the plans and matched to the specific detail. Firestop inspections may be provided under a 3 rd party inspection service under Chapter 17 Special Inspection shall be in accordance with ASTM E699, E2174 and ASTM E2393, to meet the City specialty installation inspection requirements as determined as necessary by the City. (90) Subsection 717.5.3. Shaft Enclosures. Replace the first sentence of Exception 2 with the following: Exceptions: 2. "In buildings, other than Group H occupancies, equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 or 903.3.1.2, smoke dampers are not required where:" (91) Add a new Section 803.10.1 as follows: 803.10.1 Site-fabricated stretch ceiling systems. Where used as a dropped ceiling, the following shall apply: 1. In Types I and II construction, frames shall be fabricated of non-combustible materials. 2. Where automatic sprinkler protection in accordance with Section 903.3.1.1 or 903.3.1.2 is required beneath the panel, core materials shall be fabricated of non-combustible materials. (92) Amend 803.15.2 Set-out construction. Add to the end of the sentence of Exception 3 ", or Class A mineral fiber insulation." (93) Subsection 903.1.1. Alternative Protection. Delete the text and replace with the following: 903.1.1. Alternative Protection. Where automatic sprinkler systems are required by this code; and where water as an extinguishing agent is not compatible with the fire hazard, or is prohibited by a law, statute, or ordinance, the affected area must be protected by an approved automatic fire-extinguishing system utilizing an extinguishing agent that is compatible with the fire hazard. (94) Subsections 903.2.1.1 Group A-1; Delete item number 2 and substitute the following: 2. The fire area has a calculated occupant load of 100 or more; (95) Subsection 903.2.1.2. Group A-2. Amend fourth condition by adding: Subsection 903.2.1.2. Group A-2. Add a fourth condition to read as follows: 4. The assembly occupancy is one of the following: (1) Dance halls, (2) Discotheques, (3) Nightclubs, or (4) Assembly occupancies with festival seating (see definition). (96) Subsections 903.2.1.3 Group A-3; Delete item number 2 and substitute the following: 2. The fire area has a calculated occupant load of 100 or more; (97) Subsections 903.2.1.4 Group A-4. Delete item number 2 and substitute the following: 2. The fire area has a calculated occupant load of 100 or more; (98) Subsection 903.2.1.6 Assembly Occupancies on Roofs. In the first sentence, delete "300" and substitute "100". (99) Subsection 903.2.1.7 Multiple Fire Areas. In the first sentence, delete "300" and substitute "100". (100) Subsection 903.2.3. Group E. Delete this subsection and substitute the following: An automatic sprinkler system shall be provided for all Group E occupancies. Exception: 1. An automatic sprinkler system is not required if a student occupied area has a door directly to the outside. 2. Non-relocatable buildings having an area not exceeding 1000 square feet. 3. Non-relocatable buildings containing a single classroom. 4. Relocatable buildings complying with all of the following: a) Building does not exceed 1000 square feet. b) Building contains a single classroom. c) Building is located not less than 30 feet from another building. (101) Subsection 903.2.8. Group R. Add an exception to read as follows: Exception. An automatic sprinkler system throughout the building is not required when all of the following conditions are met: 1. The building is a mixed-use building, that is not otherwise required to be protected throughout by automatic sprinklers; 2. There is only one dwelling unit in the building; 3. The dwelling unit is separated from the remainder of the building by fire barriers in accordance with Section 707 and horizontal assemblies in accordance with Section 711 having a fire resistance rating of not less than 2 hours; 4. The means of egress from the dwelling unit is independent from the other occupancies; and, 5. The dwelling unit is protected throughout with automatic sprinklers. The automatic sprinkler system installed for this exception shall be permitted to be designed in accordance with Section 903.3.1.3. (102) Subsection 903.2.8.4. Care facilities. Change the word "five" to "eight." (103) Subsection 903.2.13 Additional Suppression Requirements. Add new subsection 903.2.13 after subsection 903.2.12 as follows: 903.2.13 Additional Suppression Requirements. Fire suppression systems shall be provided for residential and nonresidential buildings or structures as follows: 903.2.13.1 If an addition or renovation to an existing R-1 or R-2 building exceeds 50% of the gross floor area, the entire building shall be protected by an approved fire protection system. 903.2.13.2 Any nonresidential building, structure, or addition to an existing nonresidential building or structure for which the initial building permit was issued on or after July 1, 1992, shall be protected by an automatic fire protection sprinkler system. 903.2.13.3 Applicable conditions and exceptions: a) Exception: a building or structure containing less than 5,000 gross square feet in floor area. The gross square feet of a building or addition shall be the sum total of the floor area for all floor levels, basements, and sub-basements, measured from outside walls, irrespective of the existence of interior fire-resistive walls, floors, or ceilings. b) If an addition to an existing building exceeds 5,000 gross square feet in floor area, the addition shall comply with this section. c) If the alteration exceeds 50% of the gross floor area of the building, the entire building shall comply with this section. d) If an alteration and addition occur simultaneously in a building, are contiguous, and the total affected floor area exceeds 5,000 gross square feet in floor area, the entire alteration and addition areas shall comply with this section. e) The building official may grant a waiver from the requirements of this section for an unusual building, structure, or occupancy. f) A sprinkler system required by this section shall be installed in accordance with NFPA Standard 13, 13D, or 13R, as applicable. (104) Subsection 903.2.14 Hose Connections. Add new subsection 903.2.14 as follows: 903.2.14 Hose Connections. Where fire suppression systems are required in Group M, S-1 and F-1 occupancies, a 2-½ inch hose connection with 1-½ inch reducers shall be provided for fire department use. Hose connections shall be placed near exit doors that do not have fire department vehicle access within 100 feet. Two hose connections shall be located no more than 200 feet apart. Exit doors shall be placarded on the outside to indicate the location of hose connections for fire department access. 903.2.14.1 Piping Design. The riser piping, supply piping, and water service piping shall be sized to maintain a residual pressure of at least 100 PSI at the top most outlet of each riser while flowing the minimum quantity of water as specified in NFPA 14. Any exceptions shall be in accordance with NFPA 14. (105) Subsection 905.3. Required installations. Preface the text with the following statement, "In new installations where the code requires either Class II or Class III standpipes, Class I standpipes must be installed. Occupant use hose is prohibited for new or existing buildings." (106) Add new section to 907.2.8 Group R1, to read as follows: 907.2.8.4 Smoke detection in sleeping areas. Smoke alarms or smoke detectors provided in sleeping areas within R-1 occupancies that are required to have a fire alarm system in accordance with this code shall be able of producing the 520 Hz low frequency audible alarm signal complying with the sleeping area requirements of NFPA 72. (107) Add Section 907.2.24 907.2.24 Child-care smoke detectors. System smoke detectors shall be installed within sleeping areas of day care facilities. Exception: Single-station smoke alarms may be permitted in facilities not otherwise required to be provided with a fire alarm system. (108) Subsection 907.4.2.3. Color. Delete in entirety. (109) Subsection 907.6.4. Zones. Add a second exception as follows: Exception: 2. Where an addressable automatic fire alarm system in accordance with Section 907 has been installed, fire alarm zoning shall be permitted to match, but not exceed, sprinkler zoning. (110) Add Exception 7 to Section 909.5.3 Smoke Barrier Construction, to read as follows: 7.0 Door openings in smoke barriers shall be permitted to be protected by self- closing fire doors in the following locations: 7.1 Guest rooms. 7.2 Individual dwelling units. 7.3 Mechanical rooms. 7.4 Elevator machine rooms. 7.5 Electrical rooms used exclusively for that purpose. 7.6 Doors typically maintained in a closed position as approved by the Building Official. (111) Subsection 909.9 Design Fire. Add the following sentence at the end of the section: In all cases, the design fire size shall not be less than 5000 BTU's (5275 kW) unless approved by the building official and the fire official. (112) Subsection 909.16. Fire Fighter's smoke control panel. In the third sentence, replace the words "approved location adjacent to the fire alarm control panel" with "location approved by the City building official and the fire official." (113) Subsection 911.1.1. Location and access. Delete and replace with the following: the fire command center shall have a door to the exterior of the building on the side where the building address is located. The exterior door to the fire command center shall be within 50 feet of a fire department access road. A fire department access box shall be provided within 6 feet of the exterior door to the fire command center. The exterior to the fire command center shall be identified on the exterior side as the "Fire Command Center" in a manner acceptable to the fire official. (114) Subsection 911.1.6. Required features. Amend Item 2 to read: 2. "The fire department communications system, which may include an in-building public safety radio enhancement system monitoring panel." Amend item 11 to read "Fire pump status indicators and remote starting." (115) Subsection 915.1. General. Delete the phrase "Section 510 of the International Fire Code" and replace with "Chapter 11, the City of Gaithersburg Fire Safety Code." (116) Subsection 916.2. Permits. Delete the phrase "as set forth in Section 105.7.11 of the International Fire Code" and replace with "Chapter 11, the City of Gaithersburg Fire Safety Code." (117) Subsection 916.7. Gas sampling. 2. Delete the phrase "with Section 6004.2.2.7 of the International Fire Code" and replace with "Chapter 11, the City of Gaithersburg Fire Safety Code." (118) Subsection 916.11. Inspection, testing and sensor calibration. Delete the phrase "the International Fire Code" and replace with "Chapter 11, the City of Gaithersburg Fire Safety Code." (119) Subsection 918.1. General. Delete and replace with the following: Emergency responder radio coverage shall be provided in all newly constructed below ground floors of a building, all floors in buildings greater than 25,000 square feet per floor, and to all floors of buildings greater than 3 stories in height. One and two family dwellings, townhouses, and "2 over 2 condos" are exempt from this requirement. (120) Section 918. Emergency responder radio coverage. Add new Subsection 918.2 as follows: 918.2. Required emergency responder radio coverage. Every floor area in a building or structure which cannot achieve the required level of emergency radio responder coverage as established by the Montgomery County Department of Technology Services shall be provided with an in-building public safety radio enhancement system in accordance with Chapter 11, the City of Gaithersburg Fire Safety Code. (121) Section 918. Emergency responder radio coverage. Add new Subsection 918.3. as follows: 918.3. Inspections and Testing. Emergency responder radio coverage and the in-building public safety radio enhancement system must be tested, and inspected by approved individuals. The results of the testing and inspection shall be certified to the code official prior to the issuance of an occupancy permit. (122) Subsection 1001.1. General. Add the following to the end of the section: "The means of egress shall also comply with the requirements in the currently adopted edition of the Life Safety Code." (123) Subsection 1003.5. Elevation change. Add the following to the beginning of the first paragraph: "Changes in level/elevation in means of egress pathways, of 21 inches or less, shall be achieved by compliant stairs or ramps. Where stairs are used, the tread depth of such stair shall not be less than 13 inches (330 mm). In the following sentence, "Where changes in elevation of less than 12 inches (305 mm) exist in means of egress, sloped surfaces shall be used". Replace the word "shall" with "may". Railings shall be provided thereon as defined under exception 2. Chapter 11 references herein are replaced by the Maryland Accessibility Code - ADAAG/2010. In Exception #2. Exceptions: 2. Replace the phrase "a single riser or with two risers and a tread" to "three risers or less". Chapter 11 references herein are replaced by the Maryland Accessibility Code - ADAAG/2010. (124) Subsection 1003.5. Elevation change. In Exception #3. Exceptions: 3. Chapter 11 references herein are replaced by the Maryland Accessibility Code - ADAAG/2010. (125) TABLE 1004.5. Areas without fixed seating. Maximum floor area allowances per occupant. Add an entry for "Shell Office Spaces" with an occupant load factor of 65 gross square feet per person. Change the occupant load factor for mercantile space from "60" to "30" in Table 1004.5. (126) Add new subsection. Subsection 1004.5.2 Festival Seating: 1004.5.2 Festival Seating. Festival seating shall be prohibited within a building, unless otherwise permitted by one of the following: 1. Festival seating shall be permitted in assembly occupancies having occupant loads of where the festival seating occupant load is 250 or less. 2. Festival seating shall be permitted in assembly occupancies where occupant loads exceed 250 and the festival seating occupant load exceeds 250, provided that an approved life safety evaluation has been performed. 3. Festival seating for less than 500 patrons (3500 square feet of open-plan area without seats) is allowed without special provisions provided seating plans are submitted and approved and all provisions of the public assembly permit process are complied with. Festival seating for greater than 500 patrons may require additional requirements/conditions to be as determined by the City Fire Marshal. 4. Festival seating shall be permitted in assembly occupancies without dance halls, discotheques, and nightclubs, where the festival seating occupant load is 1000 or less. (127) Subsection 1004.6. Fixed seating. After the last paragraph, add "The occupant load of bench-type seating, and the occupant load of bars, shall be based on one person for each 18 linear inches (455 mm) measured at the seat, or patron side of the bar, respectively." (128) Subsection 1005.3.1. Stairways. Delete all of the exceptions. (129) Subsection 1005.3.2. Other egress components. Delete all of the exceptions. (130) Subsection 1006.2.2.4. Group I-4 means of egress. Change 2½ to 2. (131) Subsection 1007.1.1. Two exits or exit access doorways. Add the following exception: Exceptions: 3. In buildings of Group R -2, four stories or less in height above the grade plane, that are served by two required exterior stairways connected by open-ended corridors in compliance with Exception 4 of Section 1026.6 (Exception 4), shall be provided with remoteness between the near edge of the required landings, that are separated by a distance of at least one third the length of the maximum overall diagonal dimension of the area served. (132) Subsection 1010.1.2. Egress Door Types. Add a second sentence at the end of the first paragraph to read: "Doors in exit enclosures shall swing in the direction of egress travel unless the door opening serves and individual living unit that opens directly into an exit enclosure." (133) Subsection 1010.1.7. Door arrangement. Amend exception to add the following; 4. The space between doors serving access vestibules of smokeproof enclosures shall be permitted to be in accordance with Section 909.20.1. (134) Subsection 1010.2.7. Stairway doors. In Exception #3. Exceptions: 3. delete all text after the phrase"… openable from the egress side." (135) Subsection 1011.5.2. Riser height and tread depth. Add the following to the end of the first paragraph: "Changes in level/elevation in means of egress pathways, of 21 inches or less, shall be achieved by compliant stairs or ramps. Where stairs are used, the tread depth of such stair shall not be less than 13 inches (330 mm). (136) Subsection 1012.6. Landings. At the end of the last sentence, add the phrase "unless, in the opinion of the AHJ, an extension in the same direction of the stair or ramp creates a hazard in the means of egress." (137) Subsection 1014.6. Handrail extensions. At the end of the last sentence add the phrase "unless, in the opinion of the AHJ, an extension in the same direction of the stair or ramp creates a hazard in the means of egress." (138) Subsection 1014.7. Clearance. Change "1½" to "2¼", and change "38mm" to "57 mm". Add sentence at the end of the paragraph, Requirement aligns with the Chapter 11, the City of Gaithersburg Fire Safety Code. (139) Subsection 1015.2. Where required. After "including," add "but not limited to." After the phrase "equipment platforms," add the phrase "retaining walls" (140 Add new Subsection 1015.2.2. Subsection 1015.2.2. Cable railing systems. 1015.2.2.1. Requirements. (a) Horizontal and vertical cable railing systems are allowed with the following stipulations: 1) Residential guard railings, 36" height minimum. Commercial guard railings, 42" height minimum. 2) Vertical posts, wood, aluminum, or steel: 48" maximum center-to-center spacing. 3) Guard opening limitations: Cables shall be installed at 3" maximum center-to-center spacing. 4) Cable tension: 225 lbs. minimum. 5) Cable sleeves shall be provided on all posts, regardless of material. (b) Guardrails in Group R occupancies shall not contain: 1) Horizontal rails other than the top and bottom rails. 2) Required guards shall not be constructed with horizontal rails or any other ornamental pattern that results in a "climbable" railing system. 3) Cutouts or indentations greater than 1¼" in width or protrusions that may provide a foothold for "young children". (141) Subsection 1015.3. Height. In exceptions #1 and #2, Exceptions: change "34 inches (864 mm)" to "36 inches (915 mm)." change "34 inches (864 mm)" to "36 inches (915 mm)." Add a seventh exception: 7. In occupancies in Group R-3, and within individual dwelling units in occupancies in Group R-2, interior guards shall not be less than 36 inches high. (142) Subsection 1015.4. Opening limitations. Delete exception #6. (143) Subsection 1015.8. Window openings. Add two exceptions (#5 and #6) to read as follows: Exceptions: 5. In buildings four stories or less, the lowest part of the clear opening of the window shall be permitted to be at a height not less than 18 inches (457mm) above the finished floor surface of the room in which the window is located. 6. In buildings four stories or less, glazing between the floor and a height of 18 inches (457mm) shall be fixed or have openings through which a 4-inch (102mm) sphere cannot pass. (144) Subsection 1015.8.1. Window opening control devices. At the end of the paragraph, add the following sentence: "Point of clarification regarding Window Opening Control Devices (WOCD). With the standard ASTM F2090 -17, windows that utilize a window opening control device shall include an automatic reset, in that, after the window opening control device is released, the device must automatically reset when the window sash is fully closed." (145) Add a new Section 1015.9 Below Grade Openings is hereby added to read as follows: 1015.9 Below Grade Openings. All area wells, stair wells and light wells attached to any building that are located less than thirty-six (36) inches (914.4 mm) from the nearest intended walking surface and deeper than thirty (30) inches (762 mm) below the surrounding ground level, creating an opening greater than twenty-four (24) inches (610 mm) measured perpendicular from the building and with side walls of such well having a slope steeper than two horizontal to one vertical, shall be provided with guards complying with section around the entire opening, or be provided with an equivalent barrier. An intended walking surface is a sidewalk, pathway, patio slab, deck or similar element. Exceptions: 1. Guards are not required on the access side of stairways. 2. Area wells provided for emergency escape and rescue openings may be protected with grilles or covers complying with Section 1031.6 of this code. 3. Grilles or covers may be placed over stairways and other openings used exclusively for service access. (146) Subsection 1016.2.1. Multiple tenants. Add the following exception: Exception: 2. In buildings of Group R-2 four stories or less in height above the grade plane that are served by two required exterior stairways connected by an open-ended corridors in compliance with Exception 4 of Section 1026.6 (Exception 4) shall be provided with remoteness between the near edge of the required landings that are separated by a distance of at least one third the length of the maximum overall diagonal dimension of the area served. (147) Section 1022. EXITS. Add a new Subsection 1022.3. to read as follows: 1022.3. Fire Department Access to Floors. Not less than one exit stair which serves all stories of the building shall be accessible by an internal corridor from the main entrance of the building or the fire department response location. (148) Section 1031.5.3 Drainage. Add a new exception # 2 to Section 1031.5.3 Drainage is hereby added to read as follows: 2. A drainage system is not required for new window wells on additions to existing dwellings where no foundation drainage system exists. (149) Chapter 11. Accessibility. Chapter 11 of the IBC related to accessibility requirements is hereby replaced with the Maryland Accessibility Code set forth in COMAR 09.12.53. Chapter 11 of the IBC requirements shall be enforced to the extent the requirements meet or exceed the requirements set forth in COMAR 09.12.53. Whenever the IBC, or the ICC Series Codes, references the IBC Chapter 11 or ANSI A 117.1, The Maryland Accessibility Code® ADAAG/2010" takes priority in the reference list of applicable codes sequence. The City of Gaithersburg, with this amendment, shall adopt some significant accessibility code changes as related to the 2021 International Building Code (IBC) & the 2017 ICC A117.1 accessible and usable buildings and facilities. The new editions, following adoption, with upsized clearance requirements of a 67-inch turning circle for chairs, shall be applicable to all new and newly renovated buildings, while the earlier codes will address current existing building conditions, typically a 60-inch turning circle. Required minimum dimensions for clear floor space, T shaped spaces and turnarounds, accessible route clear width, passing space, doorway maneuvering, and lift requirements, all have size increases as well for new and newly renovated buildings with the ANSI-A117.1-2017-Update. (150) Section 1210. Toilet And Bathroom Requirements. 1210.4 Baby Changing Tables Insert new Subsection 1210.4 as follows: 1210.4 Baby Changing Tables. Wherever a new restroom is constructed or renovated in an existing building for use by the public, a baby-changing table shall be installed and shall comply with ADA Sections 307 Protruding Objects, 309 Operable Parts, and 902 Work Surfaces. A baby-changing table must be available to both sexes, and when deployed shall not obstruct or reduce the required width of an accessible route. The baby-changing table shall be located in a common area or within restrooms, both female and male, and meet ADA compliance requirements. Device installation and use must comply with 2010 ADA Standards, which addresses the clear floor space (30 inches by 48 inches (760 by 1220mm)) requirement, design of handles and controls (operable with one hand, without tight grasping, pinching, or twisting of the wrist), required force (maximum of 5 pounds of force (lbf) (22.2 N)), mounting height (working surface in the down position, 34 inches maximum height, (865mm)), knee space (27 inches to underside (685mm)) and toe space beneath (17 inches to 25 inches, (430 to 685mm)). Exception: A facility that has been issued a permit or license which restricts the admission of children on the basis of age shall be exempt from this requirement. 1210.5 Adult Changing Tables Insert new Subsection 1210.5 as follows: 1210.5 Adult Changing Tables. Guideline minimum specification only where required or specified: Provide a floor-supported changing table, sized for use by adults, which can support individuals weighing a minimum of 400 pounds (180 kilograms). Table surfaces must be easily cleanable using steam or power-spray equipment. Do not permanently attach table to wall or floor to permit cleaning of spills on and around wall and floor surfaces behind and under table. Design table with the following characteristics: 1. Removable top. 2. Adjustable leveling feet. 3. Rounded edges and corners on open sides of table. 4. Located against an inside corner of the room. 5. Minimum 6-inch high back- and end-splash, integral with top. Loose splashes are not permitted. 6. Medical examining table paper roller at end of table. 7. Duplex convenience outlet (GFCI), and emergency call switch with pull cord within reach of individuals using changing table and assistant. Call switch destination shall be determined. Wood framing and panel products used in the design of the table are to be fire-retardant-treated. Metals, including fasteners, are to be corrosion-resistant or otherwise protected from corrosion, including the effects of cleaning chemicals. Fasteners securing removable top are to be tamper-resistant. Grab Bars are to be installed along the full length and width of changing tables. Provide at least one intermediate support for grab bars installed along the length of changing tables. Comply with Maryland Accessibility Code requirements for grab bars, except increase structural strength requirements to 400 pounds (1770 N). Peened grip for grab bars is optional. Assistant's Chair: Subject to program requirements. (151) Add new Section 1211. "Visual Mold" to read as follows: Section 1211. Visual Mold. 1211.1 General. All structures constructed under the provisions of this code shall be free from any signs of visual mold. Construction materials that exhibit visual signs of mold shall be removed and replaced. Exception: At the discretion of the City Building Official upon inspection, non-porous materials may be treated to remove mold as directed by an approved environmental engineer accepted by the City of Gaithersburg. (152) Subsection 1404.19. Add new Subsection 1404.19. 1404.19. Combustible exterior wall coverings. Exterior siding made with any plastic, vinyl, or similar polymer material must be installed with a noncombustible substrate (exterior wall sheathing) directly beneath it. (153) Subsection 1405.1.1. Types I, II, III, and IV Construction. Add new paragraph 5. 5. Exterior siding made with any plastic, vinyl, polypropylene, or similar polymer material must be installed with a noncombustible substrate (exterior wall sheathing, listed for exterior fire exposure) directly beneath it, in both the vertical and horizontal plane. (154) Amend Section 1406 Metal Composite Materials (MCM). Add the following to the end of 1406.1 General, to read as follows: 1406.1.1 Foam plastic insulation. MCM systems containing foam plastic insulation shall also comply with the requirements of Section 2603. 1406.1.2 Labeling. MCM shall be labeled in accordance with Section 1703.5. Amend Section 1406.12 Type V construction. Add the following to the end of sentence ", not exceeding 40 feet in height." Exception: MCM on exterior walls of Type V Buildings are exempt from the height restrictions when meeting the requirements of 1406.13.4. (155) Add new Section 1410. Section 1410. Exterior Balcony and Elevated Walking Surfaces. 1410.1. Applicability. The provisions of Sections 1410.1 through 1410.2 shall apply to all parts of buildings and structures that contain any exterior balcony and elevated walking surface areas of the building or structure. 1410.2 Reference Section Requirements. IBC Sections 107.2.5, 2304.12.2.3, 2304.12.2.6, and 2304.13. (156) Amend Section 1507.2.6 Attachment. Asphalt shingles shall have the minimum number of fasteners required by the manufacturer's approved installation instructions. Where the roof slope exceeds 21 units vertical in 12 units horizontal (21:12, 175-percent slope), shingles shall be installed in accordance with the manufacturer's approved installation instructions. (157) Section 1511.2.3 Weather Protection is hereby amended to read as follows: 1511.2.3 Weather Protection. Provisions such as louvers, louver blades or flashing shall be made to protect the mechanical and electrical equipment and the building interior from the elements. Mechanical units, ducts, piping, or structures installed or replaced on roofs shall be being properly supported by curbs, pads, bases, or piers which shall be flashed to the roofing in a watertight manner. All unsupported sections of mechanical equipment shall be a minimum of twelve (12) inches (304.8 mm) above the plane of the roof so that they will not obstruct the re-roofing process. Mechanical units shall properly connect to heating, air handling, refrigeration, and ventilation equipment, including fans, blowers, and similar types of equipment. Units shall be so located that proper drainage from the roof will not be blocked or impeded. Roof openings surrounded by curbs shall be sheathed over solidly and covered with a minimum of twenty-six (26) gauge metal approved for the use, or of equal material. All seams and mitered corners shall be constructed in a watertight manner. Such curbs shall be a minimum of nine (9) inches (228.6 mm) in height. (158) Add new Section 1513. Section 1513. Rooftop Screening. 1513.1. Applicability. This section provides the applicable standards for the screening of all equipment (may include projections or accessories to equipment), located on the roof of a building, in all zoning districts within the City, at the time of new installation or any equipment replacement. Screening shall be of a material similar in quality and appearance to other areas of the building façade and which is an integral part of the building's architectural design. Types of equipment defined shall include, but is not limited to elevator shafts, heating and air conditioning units of any type, ventilation ducts and exhaust air and make-up air vents, water tanks, cooling towers, swimming pool and spa pumps and filters, transformers and generators, and similar equipment (excluding solar collectors, wind energy, or similar renewable energy devices, and related equipment), and shall be screened from public view and adjacent residential districts, and shall comply with the requirements below. 1513.2. Requirements. 1. Screening of Rooftop Equipment. Roof-mounted mechanical equipment shall not be visible in any direction (360 degrees) from a public property, a public right-of-way (from the opposite side of the abutting Primary Street), or adjacent residential property, as may be seen from a point six feet above ground level, perpendicular to the zone lot line. All screening for buildings designed (including parapet walls or other similar architectural elements) shall be constructed to a height of not less than one (1') foot above the horizontal plane of the highest (after-installation height) roof-mounted mechanical unit, HVAC and/or other equipment. Additional height screening of the top of roof-mounted mechanical equipment may be required by the City, if necessary to protect views from a residential zoning district located at a higher elevation. If free clearance or otherwise unobstructed flow or space is required by the Fire or Building Code, equipment should be positioned beyond the parapet wall so as not to be visible. Exception to Screening Requirement. Where it can be clearly demonstrated that the exterior roof-mounted or ground-mounted mechanical equipment is not visible from any public right-of-way, public property, or residential property in a residential zoning district, the City Building Official may waive the screening requirements of this section. The submittal of a plan and section/elevation drawing must document that the rooftop mechanical equipment is not visible from the opposite side of the abutting Primary Street's right of way. Submitted drawings shall indicate the point of measure and height of the mechanical screening, where applicable. 2. Large mechanical equipment, including refrigeration units for commercial, institutional and recreational buildings shall be incorporated into the building design or, alternatively, screened with the appropriate materials. Screening of roof-mounted equipment may be accomplished by solid and permanent roof-mounted screens, or with mechanical roof wells recessed below the roof line. 3. Significant heritage buildings shall have all rooftop equipment fully screened and/or integrated into the building in a way that respects and complements the building's heritage and architectural features. Screening shall be compatible with the style, materials, and color of the building upon which the equipment is located, subject to the approval of the City. 4. The elevation plans for the screening shall be submitted to, and approved by, the planning staff of the Planning and Code Administration, prior to building permit application. Site lines will be taken into consideration in determining approval of screening proposals." 5. Equipment setback from roof edges that is at least three (3) feet in depth for each one (1) foot of equipment height. 6. The construction plans for the screening must demonstrate conformance with all applicable provisions of this code (IBC) and the City Mechanical Code (IMC), and must meet any requirements for space, ventilation, or other requirements as dictated by the equipment manufacturer. 7. Exterior Noise. Roof-mounted and ground-mounted mechanical equipment shall be subject to Exterior Noise Standards. Mechanical equipment within mixed-use or commercial zoning districts shall be located so that the impact of noise on residential uses within the development and on adjacent residential uses is minimized to the greatest extent feasible in compliance with Exterior Noise Standards. 8. Ground-Mounted Mechanical Equipment. This section provides standards for the screening of mechanical equipment. Multi-unit residential and nonresidential land uses shall comply with the requirements of this section. Where mechanical equipment is allowed to be installed on ground, these items shall be screened from public view and adjacent residential districts with fences, walls, solid hedges, (subject to any allowed encroachments and/or zoning setback requirements), or other methods approved by the City. Screening shall be maintained in good condition at all times. Landscaping used as screening shall provide a dense, year-round screen. Chain link fencing with or without slats shall not be permitted. (159) Subsection 1603.1.4. Wind design data. Add to the end of the sentence of Item 1. 1. The ultimate design wind speeds in miles per hour in the City of Gaithersburg MD. for risk categories I, II, III, and IV are 105, 115, 120, and 120, respectively. The corresponding nominal design wind speeds in miles per hour are 82, 89, 93, and 93, respectively. (160) Subsection 1603.1.5. Earthquake design data. Add to the end of the sentence of Item 3. 3. The mapped spectral response acceleration parameters for Montgomery County for short period, Ss, and I-second, S1, shall be 12.5% and 5.5%, respectively. (161) TABLE 1607.1. MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS. Item 27. Roofs. Modify the uniform live load value for "Ordinary flat, pitched and curved roofs" (that are not "occupiable") to 30 pounds per square foot, non-reducible. (162) Subsection 1607.8.2. Modify item to read as follows: 1607.8.2 Fire truck and emergency vehicle loading. Add paragraph 3. 3. Structural members subject to fire truck loading shall be designed for the concentrated loads applied by the vehicle to the structure as described below: The maximum fire truck operating weight is 85,000 pounds distributed in three axles spaced 19 feet 6 inches and 4 feet 6 inches apart. The transverse wheel distance is 8 feet 2 inches. The front axle weighs 23,000 pounds and rear axles weigh 31,000 pounds each. When the ladder is up, the vehicle is raised and supported on 4 outriggers spaced 10 feet apart along the length of the vehicle and 16 feet apart in the transverse direction. Depending upon the position of the ladder, any pair of two front, side or rear outriggers apply to the structure a force of 123,552 pounds (61,776 pounds per outrigger in accordance with NFPA 1901, Chapter 20.21.42) and the remaining two outriggers apply a force of zero (0) pounds. Outrigger pad dimensions are 2 feet 2 inches wide by 2 feet 6 inches long. (163) Subsection 1607.13.2.2. Add new Subsection 1607.13.2.2. 1607.13.2.2. Roof drainage. Roof drainage shall be designed and constructed in accordance with all applicable provisions of Chapter 11 of the International Plumbing Code (2018). This amendment shall not supersede any requirements of the WSSC Plumbing Regulations. (164) Subsection 1608.2. Ground Snow Loads. Referencing TABLE 1608.2. GROUND SNOW LOADS. The ground snow load for the City of Gaithersburg is 30 psf. (165) Subsection 1612.3. Establishment of Flood Hazard Areas. Where the subsection calls for name of jurisdiction, insert "the City of Gaithersburg, as contained in Chapter 10 of the City Code." Where the subsection calls for date of issuance, insert "April 27, 1992." (166) Subsection 1704.2. Special inspections and tests. Delete Exception 4. (167) Subsection 1704.2.5. Special inspection of fabricated items. At the end of first paragraph, add the following sentence: "The exceptions to Section 1704.2 may apply, subject to City approval." (168) Subsection 1704.2.5.1. Fabricated Approval. After the title, add the following sentence: "The provisions of this Section may apply, subject to City approval." (169) Subsection 1705.2.1. Structural Steel. Modify AISC 360 Chapter N, Section N1, First User Note: Delete the sentence starting with "Additionally, where ..." (170) Subsection 1705.2.1. Structural Steel. Modify AISC 360 Chapter N, Section N5.5b: Add at the end of the paragraph "unless a higher percentage is required by the structural engineer of record." (171) Subsection 1705.2.1. Structural Steel. Modify AISC 360 Chapter N, Section N5.5b, User Note: Add at the end of the user note "unless otherwise specified by the structural engineer of record." (172) Subsection 1705.2.2. Cold Formed Steel Deck. Modify SDI QA/QC-2011 Standard by deleting subsection 2 from Section 3.2B. (173) Subsection 1705.3. Concrete Construction. Delete Exception 1 and Exception 2.3. (174) TABLE 1705.3. Concrete Construction. Required Special Inspections and Tests of Concrete Construction. Modify Item 4a. Add after ''tension loads", "Installation shall be performed by an ACI or CRSI certified adhesive anchor installer." (175) TABLE 1705.3. Concrete Construction. Required Special Inspections and Tests of Concrete Construction. Items 10 and 11. Modify the inspection frequency from "periodic" to "continuous." (176) TABLE 1705.3. Concrete Construction. Required Special Inspections and Tests of Concrete Construction. Item 11. Add the sentence to the first column, "The strength evaluation shall be demonstrated by field cured cylinders only." (177) Section 1705.6. Soils. Revise the Exception in Section 1705.6 Soils to read as follows: Exception: Where Section 1803 does not require reporting of materials and procedures for fill placement, the in-place dry density of the compacted fill shall not be less than 90% of the maximum dry density at optimum moisture content determined in accordance with ASTM D 1557. (178) TABLE 1705.6. Required Special Inspections and Tests of Soils. Items 2, 3 and 5. Modify the inspection frequency from "periodic" to "continuous." (179) Subsection 1803.2. Investigations Required. Insert at the end of the first sentence after "1805.5" "or where the building exceeds 2 stories". (180) Subsection 1808.1. Scope. After the last sentence, add "The frost line of the locality has been established by the AHJ as a minimum depth of 30 inches below the adjacent finished grade." (181) Subsection 1809.5. Frost protection. After the first numbered sentence, " insert " has been established by the AHJ as a minimum depth of 30 inches below the adjacent finished grade." (182) Subsection 1901.2.1. Plain and Reinforced Concrete. Add a new Subsection 1091.2.1. as follows: 1901.2.1. Precast structures. For precast structures, in the case of a conflict between ACI 318 and PCI Design Handbook, the requirements of ACI 318 shall control the design. (183) Section 1907.1. Delete Section 1907.1 and replace with the following: 1907.1 General. The thickness of concrete floor slabs supported directly on the ground shall not be less than 3-½ inches (89mm). A 10-mil (.010 inch; 0.254 mm) polyethylene vapor retarder conforming to ASTM E 1745 Class A requirements with joints lapped not less than 6 inches (152 mm) shall be placed between the base course or subgrade and the concrete floor slab, or other approved equivalent methods shall be used to retard vapor transmission through the floor slab. Exception: The vapor retarder is not required: 1. For detached structures accessory to occupancies in Group R-3, such as garages, utility buildings or other unheated facilities. 2. For unheated storage rooms having an area of less than 70 square feet (6.5m2) and carports attached to occupancies in Group R-3. 3. For buildings of other occupancies where migration of moisture through the slab from below will not be detrimental to the intended occupancy of the building. 4. From driveways, walks, patios and other flatwork which will not be enclosed at a later date. 5. Where approved based on local site conditions. (184) Add new Section 1909 Cold Weather Concreting, as follows: Section 1909 Cold Weather Concreting. Section 1909.1 General: All concrete shall be placed in accordance with ACI CODE-318-19: Building Code Requirements for Structural Concrete. Section 1909.1.1 Cold Weather Concreting Defined: The provisions that follow apply to "cold weather" which is defined as a period of three consecutive days when the average temperature is below 40º F, and not above 50º F for more than half of any one of those three days. A "cold weather" situation is solely based upon previous temperatures, and not upon forecasted temperatures. Section 1909.2 Protection During Cold Weather: In cold weather it is important to protect the concrete from freezing and to maintain curing conditions to ensure adequate strength development. Concrete that does not attain acceptable strength shall be removed. It has been shown through data analysis that if concrete freezes, it does not continue to gain strength in a manner consistent with normal concrete performance. Section 1909.3 Construction Practices: This summary is not necessarily all inclusive: 1. The temperature of any concrete forms, steel, and sub-grade must be a min. of 33º F and rising. 2. The sub-grade may be thawed by the use of a thermal blanket or an external heat source. The subgrade may have to be re-compacted. 3. All snow and ice shall be removed so that it does not occupy space intended to be filled with concrete. Hot air may be used for this purpose. 4. Concrete placements must be protected with insulating materials immediately and surface temperature of concrete must be maintained at a min. of 55º F for a min. of 3 days (72 hours) during cold weather. Commonly used insulating materials include: polystyrene foam sheets, urethane foam, foamed vinyl blankets, mineral wool or cellulose fibers, straw, and blanket or batt insulation. If average daily temperature falls below 25º F; concrete must be heated continuously for 3 days (72 hours) by utilizing methods such as heated enclosures, or an approved type of heat source. 5. If footings were required to be protected from freezing, foundation walls will not be allowed to be placed for at least 48 hours. Exception: If protection from freezing can be maintained for a period specified above the wall may be place after 24 hours has elapsed from the time original footing pour. 6. Accelerators - The presence of chlorides has been associated with corrosion of galvanized steel, when this material is used in permanent forms or for embedded parts and its use is not recommended in such construction. Studies have indicated that galvanic corrosion of metal is intensified by addition of calcium chloride to concrete. Calcium chloride, or other chemicals in the mix, if used in permissible amounts, will not lower the freezing point of concrete to any significant degree. The use of harmful materials to protect the concrete from freezing shall not be permitted, unless specifically instructed and accepted responsibility by the licensed design professional. 7. Air-Entraining Agents — This type of admixture, in proper amounts, increases the resistance of hardened concrete to freezing and thawing and normally at the same time improves the workability of fresh concrete. The compressive strength of air-entrained concrete at 28 days shall not be less than 90 percent of a reference mix without air entrainment. A small increase in shrinkage may occur. a. For prestressed concrete, air-entraining agents shall be permitted only if they do not contain chlorides. Section 1909.4 Inspection Process: 1. Inspectors will only approve concrete pours for the same day as the inspection. 2. Inspectors will be checking for frozen subgrade ground & whether appropriate protection blankets are on site for cure duration. 3. Concrete batch tickets may be required to determine departure time, concrete strength, & additives. 4. If the inspector believes the concrete has not been properly protected as evidenced by ice crystals in the concrete and/or crystal patterns on the concrete surface, the inspector may require additional testing and engineering to ensure that required strength has been developed. (185) Subsection 2303.1.9.3. Add new Subsection 2303.1.9.3. End Use. 2303.1.9.3. End Use. Pressure Treated Wood use shall be in accordance with the latest adopted requirements/guidelines as established by the American Wood Products Association (AWPA). Ground Contact (UC4A) treated wood shall be used in all applications typically where components are considered: 1. Difficult to maintain, repair or replace and are critical to the performance and safety of the structure. 2. Does not permit air circulation or water drainage underneath the structure. 3. When installed less than 6" above the ground. 4. When wetted on a frequent or recurring basis such as wind and wave action. 5. Where vegetation, leaf litter, or other debris will typically build up and remain in contact with the treated wood product. (186) Add new Subsection 2303.1.9.4. Cuts, Notches & Holes. Pressure Treated Wood, lumber or plywood, where field cut or drilled after treatment, the treated surface shall be field treated with copper naphthenate, the concentration of which shall contain not less than 2-percent copper metal, by repeated brushing, dipping or soaking until the wood cannot absorb more preservative. All field cut ends, notches, and drilled holes in pressure treated materials shall be field treated as established by the AWPA M4 standard. (187) Subsection 2304.12. Protection Against Decay And Termites. Add the following at the end of the first sentence: Any field cuts, notches, and holes shall be field treated in accordance with Section 2303.1.9.4. (188) Subsection 2308.3.2. Add new Subsection 2308.3.2. Bottom (Sill) Plate Anchorage. 2308.3.2.1. Applicability. Where field conditions preclude the placement of the minimum bottom plate anchors, a registered design professional may provide a design for the attachment in accordance with accepted engineering practice. Detail(s) shall be submitted for City approval (to be made part of the permit documents), signed and sealed (State of Maryland) by the registered design professional. (189) Section 2611.5. Light-Transmitting Plastic Interior Signs. Add new Section 2611.5 to read as follows: 2611.5 LED Display Panels. Signs or displays utilizing LED display panels shall comply with this section of the code. 1. Panels used for LED displays shall be listed appliances. 2. Panel displays under 100 square feet in aggregate area shall not require any additional protection. 3. Panel displays between 100 square feet and 500 square feet in aggregate area shall be located in a space protected by an automatic sprinkler system. 4. Panel displays exceeding 500 square feet and below 1,000 square feet in aggregate area shall be protected with a water curtain complying with NFPA 13 across the exposed face of the display or be located in a space protected with an automatic sprinkler system of at least Ordinary Hazard Group 2. 5. Panel displays of 1,000 or greater square feet in aggregate area shall be protected by a water curtain complying with NFPA 13 across the exposed face of the display. 6. For panel displays exceeding 500 square feet, a Fire Protection Report shall be provided to substantiate the preceding requirements are met. (190) Chapter 29. Plumbing Systems. Delete chapter in its entirety (fixture calcs may be used for design guidance) and replace with the following: "Plumbing and Gasfitting Regulations in the City of Gaithersburg are under the jurisdiction of the Washington Suburban Sanitary Commission (WSSC)." (191) Section 3001.1.1. Residential Elevators. Add new Subsection 3001.1.1. as follows: 3001.1.1.1. Residential elevators. Elevator equipment, and similar conveying systems, provided in privately owned single-family residential dwellings: 1. Shall not be required to comply with the requirements of this chapter. 2. Shall not be required to enclose the hoistway with a fire-resistance rated shaft, if the elevator shaft is protected with an approved automatic sprinkler system. 3. Shall comply with all other applicable requirements of the International Building Code. 4. Shall be subject to the applicable requirements of the Maryland Public Safety Article, Title 12, Subtitle 8. 5. Shall be listed for use by a nationally recognized testing laboratory (NRTL), installed in strict accordance with the listing and the manufacturer's installation requirements. (192) Subsections 3001.2, 3001.3, and 3001.4. Elevators and Conveying Systems. Delete and replace with the following: "Subsection 3001.2. Standards. The Maryland Department of Labor, Licensing, and Regulations, Division of Labor and Industry, regulates the design requirements, installation, inspection, and testing of all elevators, hoisting and conveying equipment." (193) Section 3107. Signs. Subsection 3107.1. General. Delete the text and replace with the following: General. "All signs, and substantial modifications to existing signs, shall conform to the requirements of the City Zoning Ordinance and all applicable provisions of this code. Where conflict exists between this code and the City Zoning Ordinance, the Zoning Ordinance shall take precedence." Signs require a separate permit. (194) Subsection 3107.2. Add new Subsection 3107.2. Sale and Rental Signs. to read as follows: "Subsection 3107.2. Sale and Rental Signs. Unless otherwise provided in the City Sign Ordinance (Chapter 24, Article a permit shall not be required for signs to announce the sale or rental of property, provided that such signs are not more than four (4) square feet in area." (195) Subsection 3107.3. Add new Subsection 3107.3. Sign Height. to read as follows: "Subsection 3107.3. Sign Height. The lowest point of any sign which extends over an area intended for unrestricted vehicular traffic shall be a minimum of 14 feet above the highest traffic surface." (196) Subsection 3109.1. Swimming Pools, Spas, and Hot Tubs. General. Add the following sentence to the end of the subsection: "Public swimming pools are also required to conform to requirements of the Montgomery County Department of Health." (197) Add a new Subsection 3109.2 Depth Definition. Minimum depth of 18 inches. In the definition as in Chapter 2, change 24 inches to 18 inches. This regulation shall also apply to fountains and any other building or site containing a water element or feature. (198) Section 3116. Add new Section 3116, Systems Furniture, to read as follows: Section 3116. Systems Furniture. 3116.1 Applicability. Systems furniture installations will require a separate building permit and a separate electrical permit unless the full scope of the systems furniture installation, to include electrical service, is scheduled under the main building permit. (199) Section 3117. Add new Section 3117. Telecommunications Equipment, to read as follows: Section 3117. Telecommunications Equipment. 3117.1 Applicability. Antenna and communication equipment installations within the City are required to be privately inspected and certified for proper installation by a duly qualified structural P.E., licensed in MD. Submit original document(s), signed and sealed, to this office, within 6 months of the issue date of this permit. 3117.2 Requirements. Electrical work shall conform to City electrical code. All work shall be done at a time and in a manner, that does not endanger public or worker safety, health and general welfare. In instances where existing equipment is being replaced, said existing equipment, attachment devices, and wiring shall be removed in entirety prior to installation of any new equipment. Contractor of record shall be responsible for obtaining all required inspections, including verification of removed equipment, and shall be required to complete work in accordance with the City approved plans and all applicable City codes and regulations, and scheduling and passing all required inspections. Failure to obtain proper inspections and/or approvals, or send the required documentation, within 4 months of completion of work, will result in the revocation of the permit and the issuance of an Official Notice to remove the antenna installation from the building, or site, at the expense of the applicant. A per diem penalty may be issued for each day the antennas remain after the compliance date passes. (200) Subsection 3302.4. Add new Subsection 3302.4. Construction in Occupied Buildings, to read as follows: "Subsection 3302.4. Construction in Occupied Buildings. Existing occupied buildings and/or spaces shall not remain occupied during construction operations. "Exception. Where the building or space is adaptable to a phasing operation that clearly demonstrates to the building official that the health, safety, and welfare of the occupants of that building is not jeopardized in any way by the construction project, and that the provisions set forth in subsection 3302.3.1 can be met." (201) Subsection 3302.4.1. Add new Subsection 3302.4.1. Safety Requirements, to read as follows: "3302.4.1. Safety Requirements. All buildings/spaces approved by the building official for construction scheduled to occur while the buildings/spaces are occupied shall conform to all applicable City of Gaithersburg codes (including a phasing plan as determined by the City), policies and procedures. (202) Subsection 3303.1. Construction Documents. At the end of the paragraph, add all demolitions of structures, partial or full, shall conform to all applicable City of Gaithersburg codes, policies and procedures. (203) Subsection 3306.10. Accessibility During Construction Operations. Add new subsection 3306.10 as follows: 3306.10 Accessibility During Construction Operations. Prior to and during construction, the contractor shall provide and properly maintain, under all weather conditions, at all times, a minimum 12-foot wide vehicular access roadway that will allow the unimpeded movement of fire or emergency rescue vehicles from an improved street to within 200 feet of the most remote building under construction on the site. The vehicular access roadway surface shall be sufficient weight bearing thickness of crusher run, stone base, blacktop, or other suitable compacted surface material approved by the building official. (204) Appendix C. Group U, Agricultural Buildings. Appendix C is hereby adopted in its entirety. (205) Appendix E. Appendix E is hereby adopted in its entirety and amended as follows; Section E101.2 Design. Following the first sentence, add "Whenever the IBC, or the ICC Series Codes, references the IBC Chapter 11 or ANSI A 117.1, add the Maryland Accessibility Code®—ADAAG/2010" which takes priority in the reference list of applicable codes sequence. (206) Appendix G. Flood Resistant Construction. Appendix G is hereby adopted in its entirety and amended as follows: "Appendix G. Section G102.1. General. Add new paragraph 11. 11. The provisions of Chapter 10 of the City of Gaithersburg Code. Section G102.2. Establishment of flood hazard areas. Replace the parentheses and the phrase within the parentheses with the effective date of this regulation. (207) Appendix H. Signs. Appendix H is adopted in its entirety except for any instances where there is a conflict with the City of Gaithersburg Sign Ordinance (City Code, Chapter 24, Article IX) or any sign-related amendments of this document, any of which shall take precedence over this appendix. (208) Appendix I. Patio Covers. Appendix I is hereby adopted in its entirety. (209) Add new Appendix N. Replicable Buildings. Appendix N Replicable buildings is hereby adopted to the extent where the review and approval requirements align with the intentions and objectives of the City of Gaithersburg Planning and Code Administration. (210) Add new Appendix O. Appendix O. Radon Gas Methods. Refer to the 2021 International Residential Code, Radon (Appendix F) is hereby adopted by the City of Gaithersburg as Appendix O for the 2021 International Building Code in its entirety and shall apply to all residential uses, 4 stories and greater in height above grade plane, including Use and Occupancy classifications. (211) Add new Appendix P. Appendix P. Appendix AF, Radon Control Methods of the 2021 International Residential Code. Appendix AF of the International Residential Code is hereby adopted in its entirety and shall apply to all residential Use and Occupancy classifications in the International Building Code - IBC. (212) Appendix P. Add new Subsection to AF103.9 Vent Pipe Identification. 103.9.1 Additional Identification Requirements. In addition to the labeling requirement above, each designated radon pipe extending vertically through the roof shall be spray painted in a contrasting color not typically associated with plumbing identity colors (ASME A13.1-2020 or OSHA 29 CFR 1910.144, 1910.145) to avoid being mistaken as a plumbing waste stack during future renovations.

(Ord. No. O-9-22, 10-3-22)

Ask a question about Gaithersburg law

Corpus searches the Gaithersburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.