Sec. 25.09.03. - Accessory buildings and structures.
a. Residential accessory buildings and structures. 1. Residential accessory buildings and structures are subject to the following development standards: Development Standards for Residential Accessory Buildings and Structures Zone | Minimum Setback Requirements | Maximum Rear Yard Building Coverage | Maximum Height at Minimum Setback Not to Exceed 1 Front | Side | Rear Side-Street Abutting | Land Abutting R-400 | All accessory buildings must be located in the rear yard except as provided in Sec. 25.09.03. a.2(g) | 30' | 3' | 3' | 15% | 12' R-200 | 25' | 3' | 3' | 15% | 12' R-150 | 30' | 3' | 3' | 15% | 12' R-90 | 20' | 3' | 3' | 25% | 12' R-75 | 20' | 3' | 3' | 25% | 12' R-60 | 20' | 3' | 3' | 25% | 12' R-60 (Qualifying Undersized Lot) | 20' | 3' | 3' | 25% | 12' R-40 | 20' | 3' | 3' | 25% | 12' 1 The height of an accessory building or structure is measured from the lowest point of the finished grade at the front of the building to the highest point of the roof, as defined in subsection 25.03.03.c.3.a. Additional height may be allowed in conformance with subsection 25.09.03.a.2(a), below. 2. Residential accessory buildings are subject to the following additional provisions: (a) Accessory buildings and structures greater than twelve (12) feet high. Accessory buildings and structures that exceed twelve (12) feet in height must be set back from all lot lines an additional three (3) feet for each additional foot (or any portion thereof) of building height up to fifteen (15) feet. Accessory buildings may exceed fifteen (15) feet in height, up to a maximum of twenty (20) feet, with no additional setback required. In no event can the height exceed the height to the peak of the main house. (b) Maximum building footprint. The maximum footprint of any one accessory building is seven hundred fifty (750) square feet and cannot exceed the footprint of the main building. The maximum footprint of all accessory buildings is one thousand (1,000) square feet. (c) Conforming structures. Accessory buildings and structures that were constructed in conformance with the standards in effect at the time they were erected are considered conforming and may be modified, repaired, or replaced so long as they conform to the standards under which they were built except that they must maintain a minimum setback of three (3) feet from any property line. (d) Historic accessory buildings. i. Contributing accessory buildings, located in a historic district zone are subject to the provisions of subsection 25.08.06.c. ii. For properties that include contributing accessory buildings, the maximum cumulative building footprint for accessory buildings may be increased by up to twenty (20) percent if granted a waiver by the Board of Appeals. The waiver may be granted if it is demonstrated that: (1) The contributing accessory building cannot be used for the desired purpose of the proposed accessory building; (2) The proposed accessory building is compatible with environmental features on the property, including significant trees; and (3) The proposed accessory building is compatible with the overall character of the neighborhood. (e) Accessory buildings on through lots. A through lot has no rear yard as defined in this chapter. However, accessory buildings may be placed in the apparent rear yard, but must be set back from the street line at least the minimum front yard setback required in the zone. Within the area between the main building and the setback line, all of the requirements for accessory buildings, including setbacks, heights, and maximum lot coverage will apply. (f) Accessory buildings on corner lots. Accessory buildings must be placed in the rear yard of a corner lot. The rear yard of a corner lot must meet the minimum rear yard setback from the lot line to the main building as set forth in the applicable zone. (g) Connection to main building. An open, unenclosed breezeway with a length not exceeding twenty (20) feet may connect a main building to one accessory building. (h) Accessory structures. i. Small open structures not exceeding a footprint of one hundred (100) square feet, such as gazebos, may be permitted with a ten-foot setback in a yard abutting a street. ii. An accessory swimming pool must be located in the rear yard. All portions of the pool must be set back at least three (3) feet from any lot line and comply with any provisions of chapter 5 of this Code. (i) Story and floor area. Accessory structures and buildings are permitted to have a floor in the unfinished attic storage area of the structure. The area covered by the floor can be equal to or less then the floor area below. For the purposes of this subsection, the installation of a floor shall not constitute a story. b. Detached accessory dwelling units. In addition to the development standards in subsection 25.09.03.a, a detached accessory dwelling unit is subject to the following requirements: 1. No more than one attached or detached accessory dwelling unit is permitted on a lot. 2. A detached accessory dwelling unit must be permanently attached to the ground by a foundation. 3. The gross floor area of a detached accessory dwelling unit must be in accordance with the following: (a) Except as provided in subsection 25.09.03.b.4(b), below, the gross floor area of an accessory dwelling unit must not exceed fifty (50) percent of the gross floor area of the main dwelling unit or seven hundred fifty (750) square feet, whichever is less. (b) Notwithstanding the foregoing, an Approving Authority must not require an accessory dwelling unit to have a gross floor area of less than four hundred (400) square feet, unless at the request of the applicant. 4. A detached accessory dwelling unit is prohibited on a lot that has an attached accessory dwelling unit. 5. Both the accessory dwelling unit and the main dwelling unit on a lot must remain under common ownership. In accordance with chapter 18, rental facilities and landlord tenant relations, only one rental license is permitted on a property. 6. Detached accessory dwelling units not in conformance with this section must be brought into compliance within twelve (12) months of September 16, 2024. c. Non-residential accessory buildings and structures. Nonresidential accessory buildings and structures are reviewed as part of the site plan review and subject to all requirements of the relevant zone and all conditions of the site plan approval.
(Ord. No. 29-09, § 9, 10-26-09; Ord. No. 8-14, § 1, 4-21-14; Ord. No. 26-15, 10-12-15; Ord. No. 13-22, 7-18-22; Ord. No. 13-24, § 2, 9-16-24)
Ask a question about Rockville law
Corpus searches the Rockville sections it holds and shows the ones that match, with their citations. Free, no sign-in.