Sec. 25.16.06. - Parking design standards.

a. Interior drive aisles and turning radii. 1. The width of interior drive aisles must not be less than: (a) Twenty-four (24) feet when used with 70- to 90-degree angled parking, except that 20-foot-wide driveways may be used in a parking structure; (b) Eighteen (18) feet when used with 46- to 69-degree angled parking; or (c) Fourteen (14) feet when used with parallel to 45-degree angled parking. 2. Interior driveways must not be less than fourteen (14) feet wide for one (1) direction circulation, or eighteen (18) feet wide for two (2) direction circulation. 3. Pavement directional arrows and/or signs must be provided in sufficient quantities and locations so as to ensure safe and efficient on-site traffic circulation. 4. At the entry into a parking facility from a public right-of-way, a minimum safety zone of ten (10) feet must be provided behind the right-of-way line to allow for maneuvering of vehicles within the parking facility. 5. Interior driveways may not be installed on a grade in excess of fourteen (14) percent. Interior drive aisles in commercial and industrial areas cannot be installed on a grade of more than ten (10) percent. This requirement may be waived by the Department of Public Works for ramps within parking structures. b. Parking spaces. 1. Each automobile parking space must be a rectangle not less than nine (9) feet wide and eighteen (18) feet long, except as follows: (a) Spaces provided for the physically handicapped and aged must be in accordance with the Maryland Building Code for the Handicapped. (b) For parallel parking spaces, the length must be increased to a minimum of twenty-one (21) feet. In addition: (i) Adequate interior driveways and entrance and exit driveways must be provided to connect each public parking space with a public street; except that, (ii) Where parking of vehicles by attendants is provided, at least thirty-three (33) percent of all parking spaces must have direct access to interior entrance and exit driveways in areas designated on the site plan for attendant parking areas. 2. Parking spaces must not be installed on a grade in excess of five (5) percent. 3. All parking spaces must be separated from walkways, sidewalks, roads, streets, or alleys by curbing and all roads, streets, alleys, sidewalks, walkways, and lot lines must be protected from vehicular overhang by wheel bumpers or curbs. Wheel bumpers or curbs must be installed at least five (5) feet from a street right-of-way line. 4. For purposes of computing the area of any parking space hereunder, a parking space may extend beyond a wheel bumper or curb provided that: (a) The computed area of such parking space does not extend beyond a wheel bumper or curb more than two (2) feet as measured along the side of the space which extends the greatest distance beyond the wheel bumper or curb; and (b) The computed area of such parking space does not extend beyond a wheel bumper or curb which is more than six (6) inches high, and the area of overhang is free of all obstructions above curb height. 5. Each parking space must be clearly marked and adequate pavement directional arrows or signs provided. 6. No off-street surface parking facility can contain more than one hundred fifty (150) spaces. If a greater number of spaces is required by this article, separate parking areas of not more than one hundred fifty (150) spaces must be provided and must be separated by a landscaped area at least ten (10) feet in width. 7. In considering a project plan or site plan, the Approving Authority may allow parking spaces on private streets to be applied towards the total parking requirement for the development. c. Entrance and exit driveways. 1. Driveways for single-unit residential or duplex buildings, or buildings containing four (4) dwelling units or less in the RMD-Infill zone, must have a width of not less than ten (10) feet. 2. For all other uses, there must be at least two (2) one-direction driveways fifteen (15) feet in width or one (1) two-direction driveway twenty-five (25) feet in width, except that two-direction driveways on four (4) lane or wider highways or within the central business district must be between twenty-five (25) and thirty-five (35) feet in width. The number, type, and width of such driveways must be as reasonably determined by the Approving Authority. 3. In the MXE, MXNC, and MXCD zones, vehicular access to a secondary residential street is prohibited. 4. In the MXE, I-L, and I-H zones, vehicular access to any residential street is prohibited. d. Paving specifications. All off-street parking and loading areas must be so drained as to prevent damage to abutting properties or public streets and must be paved with a minimum of: 1. A pervious paving material as approved by the Director of the Department of Public Works; 2. Six (6) inches of concrete; 3. Six (6) inches of bituminous asphalt; 4. Six (6) inches of compacted gravel and two (2) inches of bituminous asphalt; or 5. Other paving as approved by the Director of the Department of Public Works. e. Internal landscaping of surface parking facilities. See subsection 4.d of the landscaping, screening, and lighting manual. f. Pedestrian walkways and bicycle paths in parking facilities. The design of parking facilities must include a pedestrian and bicycle circulation plan providing full and safe access to and through the facility. Pedestrian walkways, sidewalks, crosswalks, and bike paths must be provided in all off-street parking facilities where necessary for pedestrian and cycling safety. Such walkways, sidewalks, and bike paths must be clearly marked and protected from vehicular encroachment by wheel stops or curbs. Pedestrian walkways and bike travel lanes shall be linked with walkways and lanes in adjacent parking facilities and with entrances to buildings and public sidewalks and bike facilities. All pedestrian ways that cross private travel ways must be provided with crosswalks acceptable to the Department of Public Works. g. Lighting requirements. Lighting for parking facilities must be provided in accordance with the provisions of article 17 and the landscaping, screening and lighting manual. h. Loading facilities. 1. For any building in any industrial or mixed-use zone, adequate off-street space for the loading and unloading of goods and materials must be provided, taking into consideration the size of the building and the uses allowed in such zone. 2. Each loading space provided must have a minimum width of twelve (12) feet, clearance height of at least fourteen (14) feet, and a depth sufficient to accommodate the maximum length of delivery trucks reasonably likely to serve the building. In the event that intermediate tractor-trailer (WB-50) loading or unloading is reasonably likely, a depth of sixty (60) feet must be provided. Loading space shall be located so that trucks will not obstruct pedestrian or vehicle traffic movement or project into any public right-of-way. Maneuvering area must provide a turning radius of not less than forty-eight (48) feet.

(Ord. No. 29-09, § 16, 10-26-09; Ord. No. 7-11, § 16, 6-6-11; Ord. No. 14-21, 9-27-21)

Ask a question about Rockville law

Corpus searches the Rockville sections it holds and shows the ones that match, with their citations. Free, no sign-in.