§ 5-133 — Same—Amendments
City Code of the City of Rockville, Maryland (Codified through Ordinance No. 1-26, adopted January 12, 2026. (Supp. No. 17, Update 1)) · Rockville City Code § 5-133
Corpus is an independent public-information project, not the official City of Rockville website. Stable reference: corpuslaw.us/code/6a683a9a-6b0c-4a64-81b4-0ffad6c4e667
Sec. 5-133. - Same—Amendments.
The NFPA 70, National Electrical Code, 2017 Edition (NEC), is amended in the following respects: Section 90.1 (D) is added to the NEC to read as follows: (D) Relation with the Rockville City Code, Article VIII. The requirements in this code address the fundamental principles of protection for safety. The energy conservation requirements are addressed in Article VIII and Article XIV of the Rockville City Code. Section 90.2 of the NEC is amended by adding the following: (D) Homeowners. Homeowner must take and pass an exam administered by the Inspection Services Division prior to allowing a homeowner to obtain an electrical permit for doing electrical wiring at their primary residence. This exam will be valid for two (2) years allowing the homeowner to apply for additional permits in that time frame for their primary residence. Homeowner obtained electrical permits will allow electrical wiring at their primary residence, with the exclusion of the following work: • Swimming pools, saunas or hot tubs • Service equipment installation such as heavy-ups, panel replacements, sub-panels • Replacement of SEC cable. • Overhead service mast replacements. Section 90.10 is added to the NEC to read as follows: 90.10 Appeals. 90.10.1 Board of Adjustments and Appeals. Appeals of administrative interpretations or decisions made by the Building Official shall be administered in accordance with Chapter 5, Article I, Section 5-12 of the Rockville City Code. Section 110-14(a) of the NEC is amended by adding the following: In all cases, copper-clad aluminum wire must be terminated by means of wire binding screws. The use of any type of "quick-wire" terminals where the possibility of nicking the surface of copper-clad aluminum wire does exist shall not be permitted. Section 210-5 of the NEC is amended by rewriting subsection (c) to read as follows: (C) Ungrounded conductor. Where installed in raceways, as open work, or as concealed knob-and-tube work, the ungrounded conductor shall be identified by any color other than as specified in (a) and (b) above. All ungrounded conductors of the same color shall be connected to the same ungrounded feeder conductor and the conductors for systems of different voltages shall be of different colors. Exception: As permitted in section 200-7, it is required that all multicable conductors are to be color coded as follows: For 120/208/240 Volts 2 conductors—1 white and 1 black; 3 conductors—1 white, 1 black and 1 red; 4 conductors—1 white, 1 black, 1 red, and 1 blue. For 227/480 Volts; The colors gray, brown, orange, and yellow must be use in accordance with commonly accepted trade practices. Section 210.19(A) (1) of the NEC is amended by adding the following: (c) Branch circuits smaller than #4 shall be copper conductors. Section 210.52(A) of the NEC is amended by adding the following: (5) Dwelling units. General lighting branch circuits in dwelling occupancies served by a fifteen-ampere branch circuit shall not have more than twelve (12) power consuming outlets. A duplex receptacle is considered one (1) outlet. A small appliance branch circuit in dwelling occupancies served by a twenty-ampere branch circuit shall have not more than eight (8) receptacle outlets. Section 230.2 of the NEC is amended by adding the following Exception: Exception: Individual meters to measure electrical consumption shall be provided for each dwelling unit of a multi-family group when such dwelling units have separate heating and/or cooling systems whose primary energy source is electricity. Section 230.70 of the NEC is amended to read as follows: 230.70 General.Means shall be provided to disconnect all conductors in a building or other structure from the service-entrance conductors. (A) Location. The service disconnecting means shall be installed in accordance with 230.70(A)(1), (A)(2), and (A)(3). (1) Readily Accessible Location. The service disconnecting means shall be installed at a readily accessible location either outside of a building or structure or inside not to exceed 5 feet from the point of entrance of the service conductors. (2) Bathrooms. Service disconnecting means shall not be installed in bathrooms. (3) Remote Control. Where a remote control device(s) is used to actuate the service disconnecting means, the service disconnecting means shall be located in accordance with 230.70(A)(1). (B) Marking. Each service disconnect shall be permanently marked to identify it as a service disconnect. (C) Suitable for Use. Each service disconnecting means shall be suitable for the prevailing conditions. Service equipment installed in hazardous (classified) locations shall comply with the requirements of Articles 500 through 517. Section 230.79, subsection (c) of the NEC is amended by deleting the value of "one hundred (100) amperes" and substituting therefor the value of "two hundred (200) amperes" as the minimum service disconnecting means rating for one and two-family dwellings. Section 410.36 (B) of the NEC is amended to read as follows: (B) Suspended Ceilings. All luminaries installed in suspended ceilings shall be supported directly from the building structure. A minimum of 2 wires of size No. 12 steel or larger shall be used. These wires must be tied to opposite corners of the luminaire and attached independently to the building structure. Exception: Circular luminaries with a diameter 12 inches or less may be supported with one wire of No. 12 steel or larger. Section 424.11 of the NEC is amended to add the following: Wiring for all fixed electric space heating equipment shall be copper wire only. Conductors shall terminate from the heating equipment terminals to the disconnect. Section 424.19 of the NEC is amended to add the following: The disconnect serving the equipment shall not be secured or fastened to the heating equipment. Section 426.22 of the NEC is amended by adding subsection (F) to read as follows: (F) Non-heating leads. Non-heating leads shall be of copper wire only. Section 426.23 of the NEC is amended by adding subsection (C) to read as follows: (C) Non-heating leads. Non-heating leads shall be of copper wire only. Section 500.5 (D), of the NEC is amended by adding (Informational Note No. 3) to read as follows: (Informational Note No. 3): such locations as trash or incinerator rooms. Section 503.10 (A) of the NEC is amended by adding a new paragraph (5) to read as follows: (5) No conduits, busways, wireways, or feeder cables. No conduits, busways, wireways, or feeder cables shall pass through trash or incinerator rooms. The only wiring permitted in such rooms may be circuit wiring with suitable insulation having to do with and terminating in such rooms. Conduit embedded in two (2) or more inches of concrete or masonry may be considered to be outside such rooms. Section 700.18 of the NEC is amended to read as follows: Circuits for Emergency Power. For branch circuits that supply equipment classed as emergency, there shall be an emergency supply source to which the load will be transferred automatically upon the failure of the normal supply. Any building in which standpipes are installed must have one 30-ampere, 120-volt circuit installed for each standpipe riser, supplied from the emergency panel. The wiring method for exposed work must be galvanized, threaded metal conduit. Boxes must be metal, weatherproof types with gasketed flap-door covers and threaded hubs. The wiring method for concealed work must be metal conduit with appropriate galvanized boxes having gasketed flap-door covers suitable for fire department use. The weatherproof cover must be suitable for receiving the L5-20R NEMA type twist-lock receptacle without damage. Supply wiring must be at least 75 degrees C-type wire. One single 20-ampere three-wire twist lock receptacle (NEMA L5-20R) must be installed at least as high as, and with a 2-feet offset from each hose valve connection. Each outlet box must be painted "fire-alarm red" in color and be marked "Fire Department Use Only". Note: This Section supersedes the requirements of Table 210.21(B) (2).
(Ord. No. 11-15, § 7, 6-1-15; Ord. No. 22-19, § 7, 9-9-19; Ord. No. 6-24, § I, 5-20-24)
Ask a question about Rockville law
Corpus searches the Rockville sections it holds and shows the ones that match, with their citations. Free, no sign-in.