§ 5-162 — Same—Amendments
City Code of the City of Rockville, Maryland (Codified through Ordinance No. 1-26, adopted January 12, 2026. (Supp. No. 17, Update 1)) · Rockville City Code § 5-162
Corpus is an independent public-information project, not the official City of Rockville website. Stable reference: corpuslaw.us/code/bb1ce2ce-c2ee-4ce8-9cc6-28e5d78f5a6d
Sec. 5-162. - Same—Amendments.
The ICC International Energy Conservation Code, 2021 Edition (IECC), is amended in the following respects: Section C101.1 of the IECC is amended to read as follows: C101.1 Title. This code shall be known as the Energy Conservation Code of the City of Rockville, and shall be cited as such. It is referred to herein as "this code". Section C101.3 of the IECC is amended to read as follows: C101.3 Intent. This code shall regulate the design and construction of buildings for the reduction of greenhouse gas emissions and for the efficient production, use and storage of energy over the useful life of each building. This code is intended to provide flexibility to permit the use of innovative approaches and techniques to achieve this objective. This code is not intended to abridge safety, health or environmental requirements contained in other applicable codes or ordinances. Section C102.1.1 of the IECC is amended to read as follows: C102.1.1 Above code programs. The Building Official or other authority having jurisdiction shall be permitted to deem a national, state or local energy efficiency program to exceed the energy efficiency required by this code if the program provides a detailed written energy analysis study demonstrating that the requirements in the program exceed all requirements of this code and includes a requirement for inspections of each building by an accredited independent party to determine compliance. Buildings approved in writing by such an energy efficiency program and that meet all mandatory provisions of this Article shall be considered in compliance with this code. Section C103.2 of the IECC is amended to read as follows: C103.2 Information on construction documents. Construction documents shall be drawn to scale on suitable material. Electronic media documents are permitted to be submitted where approved by the code official. Construction documents shall be of sufficient clarity to indicate the location, nature and extent of the work proposed, and show in sufficient detail pertinent data and features of the building, systems and equipment as herein governed. Details shall include, but are not limited to, the following as applicable: 1. Energy compliance path. 2. Insulation materials and their R-values. 3. Fenestration U-factors and solar heat gain coefficients (SHGCs). 4. Area-weighted U-factor and solar heat gain coefficient (SHGC) calculations. 5. Mechanical system design criteria. 6. Mechanical and service water-heating systems and equipment types, sizes fuel source and efficiencies. 7. Economizer description. 8. Equipment and system controls. 9. Fan motor horsepower (hp) and controls. 10. Duct sealing, duct and pipe insulation and location. 11. Lighting fixture schedule with wattage and control narrative. 12. Location of daylight zones on floor plans. 13. Air barrier and air sealing details, including the location of the air barrier. 14. Location of pathways for routing of raceways or cable from the renewable energy system to the electrical service panel and electrical energy storage system area and solar readiness zones. 15. Location and layout of a designated area for electrical energy storage system. 16. Location of designated EVSE spaces, EV-Ready spaces, and EV-Capable spaces in parking facilities. 17. Energy Code Compliance Checklist. Sections C103.2.2 and C103.2.3 of the IECC are added to read as follows: C103.2.2 Electrification system. The construction documents shall provide details for additional electric infrastructure, including branch circuits, conduit, or pre-wiring, and panel capacity in compliance with the provisions of this code. C103.2.3 Solar-ready system. The construction documents shall provide details for dedicated roof area, structural design for roof dead and live load, and routing of conduit or pre-wiring from solar-ready zone to electrical service panel or plumbing from solar-ready zone to service water heating system. Section C104.2 of the IECC is amended as follows: C104.2 Schedule of Permit Fees. A fee for each permit shall be paid as required, in accordance with the schedule as established by resolution of the Mayor and Council. Sections C104.3, C104.4 and C104.5 of the IECC are deleted. Section C105.2.5 of the IECC is amended to read as follows: C105.2.5 Electrical system. Inspections shall verify lighting system controls, components, meters, and additional electric infrastructure as required by the code, approved plans and specifications. Where a storage-ready zone is required, inspections shall verify space availability and pathways to electrical service. Section C108.1.1 of the IECC is amended to read as follows: C108.1.1 Conflicts. Where conflicts occur between provisions of this code and referenced codes and standards, the most restrictive provisions shall apply. Section C108.1.3 is added to the IECC to read as follows: C108.1.3 Appendices. The following appendices are incorporated by reference and are applicable to the extent they are referenced in this code: 1. Appendix CB Solar-Ready Zone - Commercial 2. Appendix CC Zero Energy Commercial Building Provisions Section C110.1 of the IECC is amended to read as follows: C110.1 Board of Adjustments and Appeals. Appeals of administrative interpretations or decisions made by the Building Official shall be administered in accordance with Chapter 5, Article I, Section 5-12 of the Rockville City Code. Section C202 General Definitions of the IECC is amended to add new definitions as follows: ALL-ELECTRIC BUILDING. A building that contains no combustion equipment, or plumbing for combustion equipment, installed within the building or building site. APPLIANCE. A device or apparatus that is manufactured and designed to utilize energy and for which this code provides specific requirements. AUTOMATIC LOAD MANAGEMENT SYSTEMS (ALMS). A control system that allows multiple connected EVSE to share a circuit or panel and automatically reduce power at each charger, reducing the total connected electrical capacity of all EVSE. BLOCK. A generic concept used in energy simulation. It can include one or more thermal zones. It represents a whole building or portion of a building with the same use type served by the same HVAC system type. COMBUSTION EQUIPMENT. Any equipment or appliance used for space heating, service water heating, cooking, clothes drying and/or lighting that uses fuel gas or fuel oil. COMMERCIAL COOKING APPLIANCES. Appliances used in a commercial food service establishment for heating or cooking food and which produce grease vapors, steam, fumes, smoke or odors that are required to be removed through a local exhaust ventilation system. Such appliances include deep fat fryers, upright broilers, griddles, broilers, steam-jacketed kettles, hot-top ranges, under-fired broilers (charbroilers), ovens, barbecues, rotisseries, and similar appliances. For the purpose of this definition, a food service establishment shall include any building or a portion thereof used for the preparation and serving of food. DEMAND RESPONSIVE CONTROL. An automatic control that can receive and automatically respond to demand response requests from a utility, electrical system operator, or third-party demand response program provider. ELECTRIC VEHICLE (EV). An automotive-type vehicle for on-road use, such as passenger automobiles, buses, trucks, vans, neighborhood electric vehicles, electric motorcycles, and the like, primarily powered by an electric motor that draws current from a rechargeable storage battery, a fuel cell, a photovoltaic array, or another source of electric current. Plug-in hybrid electric vehicles are electric vehicles having a second source of motive power. Off-road, self-propelled electric mobile equipment, such as industrial trucks, hoists, lifts, transports, golf carts, airline ground support equipment, tractors, boats and the like, are not considered electric vehicles. ELECTRIC VEHICLE SUPPLY EQUIPMENT (EVSE). The conductors, including the ungrounded, grounded, and equipment grounding conductors and the electric vehicle connectors, attachment plugs, and all other fittings, devices, power outlets, or apparatus installed specifically for the purpose of transferring energy between the premises wiring and the electric vehicle. EQUIPMENT. Piping, ducts, vents, control devices and other components of systems other than appliances that are permanently installed and integrated to provide control of environmental conditions for buildings. This definition shall also include other systems specifically regulated in this code. EV-CAPABLE SPACE. A parking space for which is there is sufficient electrical service capacity and physical space within the panel to support future installation of a minimum 40-ampere, 208/240-volt dedicated branch circuit for each EVSE space, and the installation of raceways, both underground and surface mounted, to support the EVSE. EV-READY SPACE. A parking space that is served by a NEMA 14-50R receptacle on a dedicated 40-ampere, 208/240-volt branch circuit. Such receptacle shall be located at an approved location within close proximity to the parking space. EVSE-INSTALLED SPACE. A parking space that is provided with dedicated EVSE that is fully installed from the electrical panel to the parking space. FUEL GAS. A natural gas, manufactured gas, liquified petroleum gas or a mixture of these. FUEL OIL. Kerosene or any hydrocarbon oil having a flash point not less than 100°F (38°C). HVAC TOTAL SYSTEM PERFORMANCE RATIO (HVAC TSPR). The ratio of the sum of a building's annual heating and cooling load in thousands of Btus to the sum of annual site energy consumption of the building HVAC systems in BTU. MIXED-FUEL BUILDING. A building that contains combustion equipment or includes piping for such equipment. PROPOSED DESIGN. A description of the proposed building used to estimate annual energy use for determining compliance based on total building performance and HVAC total system performance ratio. RENEWABLE ENERGY CERTIFICATE (REC). An instrument that represents the environmental attributes of one megawatt-hour of renewable electricity; also known as an energy attribute certificate (EAC). STANDARD REFERENCE DESIGN. A version of the proposed design that meets the minimum requirements of this code and is used to determine the maximum annual energy use requirement for compliance based on total building performance and HVAC total system performance ratio. Section C301.1 of the IECC is amended to read as follows: C301.1 General. Climate zone "4A except Marine" shall be used for the City of Rockville in determining the applicable requirements from Chapter 4. Sections C301.2, C301.3 and C301.4 of the IECC are deleted. Section C402.1.1 of the IECC is amended as follows: C402.1.1 Low energy buildings and greenhouses. The following low-energy buildings, or portions thereof separated from the remainder of the building by building thermal envelope assemblies complying with this section shall be exempt from the building thermal envelope provisions of Section C402. 1. Those containing no combustion equipment with a peak design rate of energy usage less than 3.4 Btu/h·ft2 (10.7 W/m2) or 1.0 watt/ft2 of floor area for space conditioning purposes. 2. Those that do not contain conditioned space. Section C402.1.1.1 of the IECC is amended to read as follows: C402.1.1.1 Greenhouses. Greenhouse structures or areas containing no combustion equipment that are mechanically heated or cooled and that comply with all of the following shall be exempt from the building envelope requirements of this code: 1. Exterior opaque envelope assemblies that comply with Sections C402.2 and C402.4.5. Exception: Low energy greenhouses that comply with Section C402.1.1. 2. Interior partition building thermal envelope assemblies that separate the greenhouse from conditioned space that comply with Sections C402.2, C402.4.3 and C402.4.5. 3. Fenestration assemblies that comply with the thermal envelope requirements in Table C402.1.1.1. The U-factor for a roof shall be for the roof assembly or a roof that includes the assembly and an internal curtain system. Exception: Unconditioned greenhouses. Section C402.1.2 of the IECC is amended to read as follows: C402.1.2 Equipment buildings. Buildings that comply with the following shall be exempt from the building thermal envelope provisions of this code: 1. Are separate buildings with floor area not more than 1,200 square feet (110 m2). 2. Are intended to house electric equipment with installed equipment power totaling not less than 7 watts per square foot (75 W/m2) and not intended for human occupancy. 3. Have a heating system capacity not greater than (17,000 Btu/hr) (5 kW) and a heating thermostat setpoint that is restricted to not more than 50°F (10°C). 4. Have an average wall and roof U-factor less than 0.200 in Climate Zones 1 through 5 and less than 0.120 in Climate Zones 6 through 8. 5. Comply with the roof solar reflectance and thermal emittance provisions for Climate Zone 1. 6. Contain no combustion equipment. Section C403.1 of the IECC is amended to read as follows: C403.1 General. Mechanical systems and equipment serving the building heating, cooling, ventilating or refrigerating needs shall comply with one of the following: 1. Sections C403.1.1 and C403.2 through C403.14 2. Data Centers shall comply with C403.1.1, C403.1.2 and C403.6 through C403.14 3. Section C403.1.3 and sections within Section C403 that are listed in Table C407.2 Section C403.1.3 is added to the IECC to read as follows: C403.1.3 HVAC total system performance ratio (HVAC TSPR). HVAC systems serving buildings or portions of buildings listed in C403.1.3.1 that are not served by systems listed in C403.1.3.2 shall have an HVAC total system performance ratio (HVAC TSPR) of the proposed design HVAC systems that is greater than or equal to the HVAC TSPR of the standard reference design divided by the applicable mechanical performance factor (MPF) from Table C409.4 C403.1.3.1 Included Building Types. HVAC systems that serve the following building use types are eligible to use HVAC TSPR as a compliance path: 1. office (including medical office) (occupancy group B), 2. retail (occupancy group M), library (occupancy group A-3), 3. education (occupancy group E). 4. hotel/motel occupancies (occupancy group R-1). 5. the dwelling units and common areas within occupancy group R-2 multifamily buildings. C403.1.3.2 Excluded Systems. The following HVAC systems are not eligible to use HVAC TSPR as a compliance path 1. Systems using: 1.1 district heating water, chilled water or steam 1.2. small duct high velocity air cooled, space constrained air cooled, single package vertical air conditioner, single package vertical heat pumps. 1.3 double-duct air conditioner or double-duct heat pump as defined in subpart F to 10CFR part 431 1.4 packaged terminal air conditioners and packaged terminal heat pumps that have cooling capacity greater than 12,000 BTU/hr (3500 kW) 1.5 a common heating source serving both HVAC and service water heating equipment 2. Systems that provide recovered heat for service water heating 3. Systems not included in Table C409.6.1.10.1 4. Systems included in table C409.6.1.10.1 with parameters in Table C409.6.1.10.2(1), not identified as applicable to that system type. 5. Systems with chilled water supplied by absorption chillers, heat recovery chillers, water to water heat pumps, air to water heat pumps, or a combination of air- and water-cooled chillers on the same chilled water loop. 6. Systems served by heating water plants that include air to water or water to water heat pumps. 7. Underfloor air distribution and displacement ventilation HVAC systems. 8. Space conditioning systems that do not include mechanical cooling. 9. Systems serving laundry rooms, elevator rooms, mechanical rooms, electrical rooms, data centers, and computer rooms. 10. Buildings or areas of medical office buildings that comply fully with ASHRAE Standard 170, including but not limited to surgical centers, or that are required by other applicable codes or standards to provide continuous air handling unit operation. 11. Systems serving: 11.1 laboratories with fume hoods 11.2 Locker rooms with more than 2 showers 11.3 Natatoriums and rooms with saunas 11.4 Restaurants and commercial kitchens with total cooking capacity greater than 100,000 Btu/h 11.5 Areas of buildings with commercial refrigeration equipment exceeding 100 kW of power input 11.6 Cafeterias and dining rooms C403.1.3.3 TSPR Method Partial Prescriptive Requirements. HVAC systems using the HVAC Performance Rating Method shall meet relevant prescriptive requirements in Section C403 as follows: 1. Air economizers shall meet the requirements of Section C403.5.3.4 and Section C403.5.5. 2. Variable-air-volume system systems shall meet requirements of Sections C403.6.5, C403.6.6, and C403.6.9. 3. Hydronic systems shall meet the requirements of C403.4.4. 4. Plants with multiple chillers or boilers shall meet the requirements of Section C403.4.5. 5. Hydronic Heat Pumps and Water-Cooled Unitary Air Conditioners shall meet the requirements of Section C403.4.3.3. 6. Cooling tower turndown shall meet requirements of Section C403.10.4. 7. Heating of unenclosed spaces shall meet the requirements of Section C403.13.1. 8. Hot-gas bypass shall meet the requirements of Section C403.3.3. 9. Refrigeration systems shall meet the requirements of Section C403.11. Section C403.4.1 is added to the IECC to read as follows: C403.4.1.6 Demand responsive controls. All thermostatic controls shall be provided with demand responsive controls capable of the following: 1. Automatically increasing the zone operating cooling set points by a minimum of 4°F (2.2°C) 2. Automatically decreasing the zone operating heating set points by a minimum of 4°F (2.2°C) 3. Automatically decreasing the zone operating cooling set points by a minimum of 2°F (1.1°C). 4. Both ramp-up and ramp-down logic to prevent the building peak demand from exceeding that expected without the DR implementation. The thermostatic controls shall be capable of performing all other functions provided by the control when the demand responsive controls are not available. Systems with direct digital control of individual zones reporting to a central control panel shall be capable of remotely complying. Exceptions: 1. Health care and assisted living facilities. 2. Systems serving areas deemed by the owner to be critical in nature, where approved by the Building Official. Section C404.2.1 of the IECC is amended to read as follows: C404.2.1 High input service water-heating systems. Gas-fired water-heating equipment installed in new buildings shall be in compliance with this section. Where a singular piece of water-heating equipment serves the entire building and the input rating of the equipment is 1,000,000 Btu/h (293 kW) or greater, such equipment shall have a thermal efficiency, Et, of not less than 92 percent or a UEF of not less than 0.92 UEF. Where multiple pieces of water-heating equipment serve the building and the combined input rating of the water-heating equipment is 1,000,000 Btu/h (293 kW) or greater, the combined input-capacity-weighted-average thermal efficiency, Et, of not less than 92 percent or a UEF of not less than 0.92 UEF. Exceptions: 1. Where not less than 50 percent of the annual service water heating requirement is provided by on-site renewable energy or site-recovered energy not including any capacity used for compliance with Section C405.13 or C406 of this code, the minimum thermal efficiency requirements of this section shall not apply. 2. The input rating of water heaters installed in individual dwelling units shall not be required to be included in the total input rating of service water-heating equipment for a building. Section C404.10 is added to the IECC to read as follows: C404.10 Demand responsive water heating. All electric storage water heaters, or a group of water heaters, in a building with a total storage tank capacity greater than 37 gallons (140 L) shall be provided with demand responsive controls that comply with ANSI/CTA-2045-B or another approved demand responsive control. Exception: Health care facilities. Section C405.2 of the IECC is amended to read as follows: C405.2 Lighting controls. Lighting systems shall be provided with controls that comply with one of the following. 1. Lighting controls as specified in Sections C405.2.1 through C405.2.7. 2. Luminaire level lighting controls (LLLC) and lighting controls as specified in Sections C405.2.1, C405.2.4 and C405.2.5. The LLLC luminaire shall be independently capable of: 2.1. Monitoring occupant activity to brighten or dim lighting when occupied or unoccupied, respectively. 2.2. Monitoring ambient light, both electric light and daylight, and brighten or dim artificial light to maintain desired light level. 2.3. For each control strategy, configuration and reconfiguration of performance parameters including; bright and dim setpoints, timeouts, dimming fade rates, senso sensitivity adjustments, and wireless zoning configurations. 2.4 Reducing lighting power in a uniform manner by no less than 15 percent and no more than 50 percent when signaled by a demand responsive control. Exceptions: Lighting controls are not required for the following: 1. Areas designated as security or emergency areas that are required to be continuously lighted. 2. Interior exit stairways, interior exit ramps and exit passageways. 3. Emergency egress lighting that is normally off. Table C405.12.2 of the IECC is amended as follows: TABLE C405.12.2 ENERGY USE CATEGORIES LOAD CATEGORY | DESCRIPTION OF ENERGY USE Total HVAC system | Heating, cooling and ventilation, including but not limited to fans, pumps, boilers, chillers, and water heating. Energy used by 120-volt equipment, or by 208/120-volt equipment that is located in a building where the main service is 480/277-volt power, is permitted to be excluded from total HVAC system energy use. Interior lighting | Lighting systems located within the building. Exterior lighting | Lighting systems located on the building site but not within the building. Plug loads | Devices, appliances and equipment connected to convenience receptacle outlets. Process load | Any single load that is not included in HVAC, lighting or plug load category and that exceeds 5 percent of the peak connected load of the whole building, including but not limited to data centers, manufacturing equipment, and commercial kitchens. Electric vehicle charging | Electric vehicle charging loads. Building operations and other miscellaneous | The remaining loads not included in this table, including but not limited to vertical transportation systems, automatic doors, motorized shading systems, ornamental fountains, ornamental fireplaces, swimming pools, in-ground spas and snow-melt systems. Section C405.13 is added to the IECC to read as follows: C405.13 On site renewable energy. Each building site shall comply with Appendix CB: Solar-Ready Zone - Commercial. Exceptions: 1. Sites containing only buildings with unconditioned space. 2. Sites containing only Group U occupancy buildings. Section C405.14 is added to the IECC to read as follows: C405.14 Electric vehicle charging infrastructure. Parking facilities shall be provided with electric vehicle charging infrastructure in accordance with this section and Table C405.14. C405.14.1 Minimum quantity. The minimum number of parking spaces provided with electric vehicle infrastructure shall be based on the total number of parking spaces provided, and rounded up to the nearest whole number. Where reductions are applied in accordance with Section C405.14.2, in no case shall fewer than one of each type of space be provided. C405.14.1.1 More than one parking facility. Where more than one parking facility is provided on a building site, the number of parking spaces provided with electric vehicle infrastructure shall be calculated separately for each parking facility. C405.14.1.2 Serving multiple occupancies. Where one shared parking facility serves multiple building occupancies, the required number of parking spaces provided with electric vehicle infrastructure shall be determined proportionally based on the floor area of each building occupancy. C405.14.1.3 Accessible spaces. The required number of parking spaces provided with electric vehicle infrastructure that are designed for accessibility shall be in accordance with Section 1107.2 of the International Building Code. None of the reductions permitted by section C405.14.2 shall reduce the number of required accessible spaces. C405.14.2 Reductions. The minimum number of spaces required to be provided with electric vehicle charging infrastructure may be reduced as follows: 1. The number of required EVSE-Installed spaces for Groups A, B, E, F, I, M and S-2 Occupancies may be reduced by ten (10) for each DC Fast-Charging EVSE installed. 2. Parking spaces designated for vehicles other than passenger vehicles are permitted to be excluded from the total number of on-site parking spaces. 3. Parking spaces designated for quick transactions, such as takeout, pickup, and drop-off are permitted to be excluded from the total number of on-site parking spaces. 4. EVSE-installed spaces above the minimum required number are permitted to be installed to meet the minimum required number of EV-Ready Spaces or the minimum required number of EV-Capable Spaces. 5. EV-Ready spaces above the minimum required number are permitted to be installed to meet the minimum required number of EV-Capable Spaces. 6. The number of required EV-Capable Spaces for Groups R-1, R-2 and R-4 Occupancies may be reduced by 50% where a Long-Term EV Charging Management Plan has been submitted and approved by the building official. TABLE C405.14 ELECTRIC VEHICLE CHARGING INFRASTRUCTURE REQUIREMENTS OCCUPANCY GROUP | EVSE INSTALLED | EVSE READY | EVSE CAPABLE Groups A, B, E, F, I, M, S-2 | 2% | 8% | 10% Groups R-1, R-2, R-4 | 10% | 10% | 30% C405.14.3 Classification of Spaces. The parking spaces required by this section shall be classified in accordance with C405.14.3.1, C405.14.3.2, or C405.14.3.3. C405.14.3.1 EV-Capable Spaces. For a parking space to qualify as an EV-Capable Space, the following requirements must be met: 1. A raceway or other approved means of cable protection, installed between the panel and the point of termination. 2. The point of termination shall be an approved enclosure, such as a junction box, and shall be installed within 36" (914 mm) of the parking space, or within close proximity of the parking space, as determined by the Building Official. 3. Dedicated physical space shall be provided within the panel for future installation of a 40-ampere overcurrent protective device. 4. Durable approved labels shall be installed at the panel and the point of termination, identifying the infrastructure "For Electric Vehicle Charging" C405.14.3.2 EV Ready Spaces. For a parking space to qualify as an EV-Ready Space, a dedicated 40-Ampere, 208/240v branch circuit shall be provided, which meets all of the following requirements: 1. The branch circuit shall serve no other appliances or equipment 2. The branch circuit shall terminate in an approved enclosure within 36" (914 mm) of the parking space, or where site conditions prohibit, within close proximity of the parking space, as determined by the Building Official. 3. The overcurrent protective device and the approved enclosure in which the circuit terminates shall be provided with durable approved labels, identifying the infrastructure "For Electric Vehicle Charging." C405.14.3.3 EV-Installed Spaces. Equipment serving EVSE-Installed Spaces shall meet all of the following requirements: 1. The equipment shall be capable of supplying an output of not less than 6.2 kW. Exception: Where connected to an approved Automatic Load Management System (ALMS), the EVSE shall be permitted to supply a reduced output, provided that every EVSE connected to the ALMS is capable of charging at a minimum rate of 1.4 kW simultaneously. 2. The equipment shall be located within 36" of the parking space, or where site conditions prohibit, within close proximity of the parking space, as determined by the Building Official. Section C405.15 is added to the IECC to read as follows: C405.15 Energy storage infrastructure. Each building site shall be provided with a dedicated space for on-site energy storage equipment. Such space shall be not less than 2 feet (610 mm) in one horizontal dimension and 4 feet (1219 mm) in another horizontal dimension, and shall be located and protected in accordance with NFPA 1, NFPA 101, and NFPA 70. Exception: Where an approved onsite electrical energy system storage system is installed. C405.15.1 Electrical service reserved space. The main electrical service panel shall have a reserved space to allow installation of a two-pole circuit breaker for future electrical energy storage system installation This space shall be labeled "For Future Electric Storage." The reserved space shall be positioned at the end of the panel that is opposite from the panel supply conductor connection. Section C405.16 is added to the IECC to read as follows: C405.16 Additional electric infrastructure. Buildings that contain combustion equipment and end-uses shall be required to install electric infrastructure in accordance with this section. C405.16.1 Electric infrastructure for dwelling and sleeping units. Combustion equipment and end-uses serving individual dwelling units or sleeping units shall comply with Section R404.6. C405.16.2 Combustion space heating. Space heating equipment that uses fossil fuels shall comply with either C405.16.2.1 or C405.16.2.2 C405.16.2.1 Low-capacity heating. Warm-air furnaces with a capacity less than 225,000 Btu/h and gas- and oil-fired boilers with a capacity less than 400,000 Btu/h shall be provided with a designated exterior location(s) in accordance with the following: a. Natural drainage for condensate from cooling equipment operation or a condensate drain located within 3 feet (914 mm) of the location of the space heating equipment. b. A dedicated branch circuit in compliance with NFPA70 Section 424.4 based on heat pump space heating equipment sized in accordance with the requirements of C403.1.1 and terminating within 3 feet (914 mm) of the location of the space heating equipment with no obstructions. Both ends of the branch circuit shall be labeled "For Future Heat Pump Space Heater." Exception: Where an electrical circuit in compliance with NFPA70 Sections 440.4(B) and 440.35 exists for space cooling equipment. C405.16.2.2 High-capacity heating. All other space heating equipment shall be provided with conduit that is continuous between a junction box located within 3 feet (914 mm) of the equipment and an electrical panel. The junction box, conduit and bus bar in the electrical panel shall be rated and sized to accommodate a branch circuit with sufficient capacity for an equivalent electric equipment with an equivalent equipment capacity. The electrical junction box and electrical panel shall have labels stating, "For Future Electric Space Heating Equipment". C405.16.3 Combustion water heating. Water heating equipment that uses fossil fuels shall comply with either C405.16.3.1 or C405.16.3.2 C405.16.3.1 Low-capacity water heating. Water heaters with a capacity less than 300,000 Btu/h (88 kW) shall be installed in accordance with the following: 1. A dedicated 208/240-volt branch circuit with a minimum capacity of 30 amps shall terminate within 3 feet (914 mm) from the water heater and be accessible to the water heater with no obstructions. Both ends of the branch circuit shall be labeled with the words "For Future Heat Pump Water Heater" and be electrically isolated. 2. A condensate drain that is no more than 2 inches (51 mm) higher than the base of the installed water heater and allows natural draining without pump assistance shall be installed within 3 feet (914 mm) of the water heater. 3. The water heater shall be installed in a space with minimum dimensions of 3 feet (914 mm) by 3 feet (914 mm) by 7 feet (2134 mm) high. 4. The water heater shall be installed in a space with a minimum volume of 700 cubic feet (20,000 L) or the equivalent of one 16-inch (406 mm) by 24-inch (610 mm) grill to a heated space and one 8-inch (203 mm) duct of no more than 10 feet (3048 mm) in length for cool exhaust air. C405.16.3.2 High-capacity water heating. Water heaters with a capacity greater than or equal to 300,000 Btu/h (88 kW) shall be provided with the following: 1. Conduit that is continuous between a junction box located within 3 feet (914 mm) of the equipment and an electrical panel. The junction box, conduit and bus bar in the electrical panel shall be rated and sized to accommodate a branch circuit with sufficient capacity for an equivalent electric equipment with an equivalent equipment capacity. The electrical junction box and electrical panel shall have labels stating, "For Future Electric Water Heating Equipment". 2. A condensate drain that is no more than 2 inches (51 mm) higher than the base of the installed water heater and allows natural draining without pump assistance shall be installed within 3 feet (914 mm) of the water heater. C405.16.4 Combustion cooking. Cooking equipment that use fossil fuel shall comply with either C405.16.4.1 or C405.16.4.2. C405.16.4.1 Commercial cooking. Commercial cooking appliances shall be provided with a dedicated branch circuit with a minimum capacity of 12 kVA per 1 kBtu of appliance input capacity. The branch circuit shall terminate within 3 feet (914 mm) of the appliance with no obstructions. Both ends of the branch circuit shall be labeled with the words "For Future Electric Cooking Equipment" and be electrically isolated. C405.16.4.2 Light and medium duty cooking. Light- and medium duty cooking equipment not designated as commercial cooking appliances shall be provided with a dedicated branch circuit in compliance with NFPA 70 Section 422.10. The branch circuit shall terminate within 6 feet (1829 mm) of fossil fuel ranges, cooktops and ovens and be accessible with no obstructions. Both ends of the branch circuit shall be labeled with the words "For Future Electric Cooking Equipment" and be electrically isolated. C405.16.5 Combustion clothes drying. Clothes drying equipment that use fossil fuels shall comply with either C405.16.5.1 or C405.16.5.2 C405.16.5.1 Commercial drying. Clothes drying equipment, and end-uses for commercial laundry applications shall be provided with conduit that is continuous between a junction box located within 3 feet (914 mm) of the equipment and an electrical panel. The junction box, conduit and bus bar in the electrical panel shall be rated and sized to accommodate a branch circuit with sufficient capacity for an equivalent electric equipment with an equivalent equipment capacity. The electrical junction box and electrical panel shall have labels stating, "For Future Electric Clothes Drying Equipment". C405.16.5.2 Residential drying. Clothes drying equipment, appliances, and end-uses serving multiple dwelling units or sleeping areas with a capacity less than or equal to 9.2 cubic feet shall be provided with a dedicated 240-volt branch circuit with a minimum capacity of 30 amps shall terminate within 6 feet (1829 mm) of fossil fuel clothes dryers and shall be accessible with no obstructions. Both ends of the branch circuit shall be labeled with the words "For Future Electric Clothes Drying Equipment" and be electrically isolated. C405.16.6 Other combustion equipment. Combustion equipment not covered by Sections C405.16.2-3 shall be provided with conduit that is continuous between a junction box located within 3 feet (914 mm) of the appliance or equipment and an electrical panel. The junction box, conduit and bus bar in the electrical panel shall be rated and sized to accommodate a branch circuit with sufficient capacity for an equivalent electric appliance, equipment or end use with an equivalent equipment capacity. The electrical junction box and electrical panel shall have labels stating, "For future electric equipment". Section C406.1 of the IECC is amended to read as follows: C406.1 Additional energy efficiency credit requirements. New all-electric buildings shall achieve a total of 10 credits and new mixed-fuel buildings shall achieve a total of 15 credits from Tables C406.1(1) through C406.1 (5) where the table is selected based on the use group of the building and from credit calculations as specified in relevant subsections of C406. Where a building contains multiple use groups, credits from each use group shall be weighted by floor area of each group to determine the weighted average building credit. Credits from the tables or calculation shall be achieved where a building complies with one or more of the following: 1. More efficient HVAC performance in accordance with Section C406.2. 2. Reduced lighting power in accordance with Section C406.3. 3. Enhanced lighting controls in accordance with Section C406.4. 4. On-site supply of renewable energy in accordance with Section C406.5. 5. Provision of a dedicated outdoor air system for certain HVAC equipment in accordance with Section C406.6. 6. High-efficiency service water heating in accordance with Section C406.7. 7. Enhanced envelope performance in accordance with Section C406.8. 8. Reduced air infiltration in accordance with Section C406.9 9. Where not required by Section C405.12, include an energy monitoring system in accordance with Section C406.10. 10. Where not required by Section C403.2.3, include a fault detection and diagnostics (FDD) system in accordance with Section C406.11. 11. Efficient kitchen equipment in accordance with Section C406.12. Table 406.1(1), 406.1(2), 406.1(3), 406.1(4), and 406.1(5) of the IECC are amended to add the following rows: Table C406.1(1) Additional Energy Efficiency Credits for Group B Occupancies Sub-section/Climate Zone: | 4A C406.13 HVAC TSPR | 6 Table C406.1(2) Additional Energy Efficiency Credits for Group R and I Occupancies Sub-section/Climate Zone: | 4A C406.13 HVAC TSPR | 6 Table C406.1(3) Additional Energy Efficiency Credits for Group E Occupancies Sub-section / Climate Zone: | 4A C406.13 HVAC TSPR | 8 Table C406.1(4) Additional Energy Efficiency Credits for Group M Occupancies Sub-section / Climate Zone: | 4A C406.13 HVAC TSPR | 8 Table C406.1(5) Additional Energy Efficiency Credits for OtheraOccupancies Sub-section / Climate Zone: | 4A C406.13 HVAC TSPR | 6 Section C406.5.1 of the IECC is amended to read as follows: C406.5.1 Onsite renewable energy. The total minimum ratings of on-site renewable energy systems, not including onsite renewable energy system capacity used for compliance with Section C405.13, shall be one of the following: 1. Not less than 0.86 Btu/h per square foot (2.7 W/m 2 ) or 0.25 watts per square foot (2.7 W/m 2 ) of conditioned floor area. 2. Not less than 2 percent of the annual energy used within the building for building mechanical and service water-heating equipment and lighting regulated in Section C405. Section C409 is added to the IECC to read as follows: SECTION C409 HVAC TOTAL SYSTEM PERFORMANCE RATIO C409.1 Purpose. This Section establishes criteria for demonstrating compliance with the requirements of section C403.1.1, HVAC total system performance ratio (HVAC TSPR) C409.2 Scope. This Section applies to new HVAC systems that are not excluded from using HVA C TSPR by any of the exceptions to section C403.1.1, and 1. serve office (including medical office), retail, library, hotel/motel, and education occupancies, or. 2. serve dwelling units and common areas within multifamily buildings. C409.2 Phased Installation. Where the building permit applies to only a portion of the HVAC system in a building and the remaining components will be designed under a future building permit or were previously installed, the future or previously installed components shall be modeled as follows: 1. Where the HVAC zones that do not include HVAC systems in the current permit will be or are served by independent systems, then the block including those zones shall not be included in the model. 2. Where the HVAC zones that do not include complete HVAC systems in the permit are intended to receive HVAC services from systems in the permit, their proposed zonal systems shall be modeled with equipment that meets, but does not exceed, the requirements of C403. 3. Where the zone equipment in the permit receives HVAC services from previously installed systems that are not in the permit, the previously installed systems shall be modeled withequipment matching the certified value of what is installed or equipment that meets the requirements of C403. 4. Where the central plant heating and cooling equipment is completely replaced and HVAC zones with existing systems receive HVAC services from systems in the permit, their proposed zonal systems shall be modeled with equipment that meets, but does not exceed, the requirements of Section C403. C409.3 HVAC TSPR Compliance. Systems required to use HVAC TSPR in accordance with C403.1.3 shall comply with all of the following: 1. Systems shall meet the applicable provisions of Section C403.1.3.3 and Sections within Section C403 that are listed in Table C407.2. 2. The HVAC TSPR of the proposed design shall be greater than or equal to the HVAC TSPR of the standard reference design divided by the mechanical performance factor (MPF) using Equation 4- 16. TSPRp > TSPRr / MPF Equation 4-16 Where: TSPRp= HVAC TSPR of the proposed design calculated in accordance with Sections C409.4, C409.5 and C409.6. TSPRr = HVAC TSPR of the reference building design calculated in accordance with Sections C409.4, C409.5 and C409.6. MPF = Mechanical Performance Factor from Table C409.4 based on climate zone and building use type Where a building has multiple building use types, MPF shall be area weighted using Equation 4-17 MPF = (A1 * MPF1 + A2 * MPF2 + ... + An * MPFn) / (A1 + A2 + ... + An) Equation 4-17 Where: MPF1, MPF2 through MPFn = Mechanical Performance Factors from Table C409.4 based on climate zone and building use types 1,2, through n A1, A2 through An = Conditioned floor areas for building use types 1, 2, through n Table C409.4 Mechanical Performance Factors Climate Zone: Building type | Ocp. Group | 4A Office (small and medium) a | B | 0.81 Office (Large) a | B | 0.67 Retail | M | 0.45 Hotel/Motel | R-1 | 0.45 Multi-Family/Dormitory | R-2 | 0.53 School/Education and Libraries | E(A-3) | 0.73 a large office (gross conditioned floor area >150,000 ft 2 (14,000 m 2 ) or > 5 floors): all other offices are small or medium C409.4.1 HVAC TSPR. HVAC TSPR is calculated according to Equation 4-18: HVAC TSPR = annual heating and cooling load annual energy consumption of the building HVAC systems Where: Annual energy consumption of the building HVAC systems pumps, and heat rejection in thousands of BTU's | = | Sum of the site energy consumption for heating, cooling, fans, energy recovery, Annual heating and cooling load | = | Sum of the annual heating and cooling loads met by the building HVAC system in thousands of BTU's C409.5.1 Simulation Program. Simulation tools used to calculate HVAC TSPR of the Standard Reference Design shall comply with the following: 1. The simulation program shall calculate the HVAC TSPR based only on the input for the proposed design and the requirements of Section 409. The calculation procedure shall not allow the user to directly modify the building component characteristics of the standard reference design. 2. Performance analysis tools meeting the applicable subsections of Section 409 and tested according to ASHRAE Standard 140 shall be permitted to be approved. The code official shall be permitted to approve tools for a specified application or limited scope. C409.5.2 Climatic data. The simulation program shall perform the simulation using hourly values of climatic data, such as temperature and humidity, using TMY3 data for the site as specified by the Department of Energy's Office of Energy Efficiency and Renewable Energy. C409.5.3 Documentation. Documentation conforming to the provisions of this section shall be provided to the code official. C409.5.3.1 Compliance report. Building permit submittals shall include: 1. A report produced by the simulation software that includes the following: 1.1 Address of the building. 1.2 Name of individual completing the compliance report. 1.3 Name and version of the compliance software tool. 1.4 The dimensions, floor heights and number of floors for each block. 1.5 By block, the U-factor, C-factor, or F-factor for each simulated opaque envelope component and the U-factor and SHGC for each fenestration component. 1.6 By block or by surface for each block, the fenestration area. 1.7 By block, a list of the HVAC equipment simulated in the proposed design including the equipment type, fuel type, equipment efficiencies and system controls. 1.8 Annual site HVAC energy use by end use for the proposed and baseline building 1.9 Annual sum of heating and cooling loads for the baseline building. 1.10 The HVAC total system performance ratio for both the standard reference design and the proposed design. 2. A mapping of the actual building HVAC component characteristics and those simulated in the proposed design showing how individual pieces of HVAC equipment identified above have been combined into average inputs as required by Section C409.6.1.10 including: 2.1 Fans 2.2 Hydronic pumps 2.3 Air handlers 2.4 Packaged cooling equipment 2.5 Furnaces 2.6 Heat pumps 2.7 Boilers 2.8 Chillers 2.9 Cooling towers 2.10 Electric resistance coils 2.11 Condensing units 2.12 Motors for fans and pumps 2.13 Energy recovery devices For each piece of equipment identified above include the following as applicable: 1. Equipment name or tag consistent with that found on the design documents. 2. Rated Efficiency level. 3. Rated Capacity. 4. Electrical input power for fans and pumps (before any speed or frequency control device) at design condition and calculation of input value (W/cfm or W/gpm) 3. Floor plan of the building identifying: 3.1. How portions of the buildings are assigned to the simulated blocks. 3.2. Areas of the building that are not covered under the requirements of Section C403.1.1. C409.6 Calculation Procedures Except as specified by this Section, the standard reference design and proposed design shall be configured and analyzed using identical methods and techniques. C409.6.1 Simulation of the proposed building design. The proposed design shall be configured and analyzed as specified in this section. C409.6.1.1 Block geometry. The geometry of buildings shall be configured using one or more blocks. Each block shall define attributes including block dimensions, number of floors, floor to floor height and floor to ceiling height. Simulation software may allow the use of simplified shapes (such as rectangle, L shape, H Shape, U shape or T shape) to represent blocks. Where actual building shape does not match these pre- defined shapes, simplifications are permitted providing the following requirements are met: 1. The conditioned floor area and volume of each block shall match the proposed design within 10 percent. 2. The area of each exterior envelope component from Table C402.1.4 is accounted for within 10 percent of the actual design. 3. The area of vertical fenestration and skylights is accounted for within 10 percent of the actual design. 4. The orientation of each component in 2 and 3 above is accounted for within 45 degrees of the actual design. The creation of additional blocks may be necessary to meet these requirements. Exception: Portions of the building that are unconditioned or served by systems not covered by the requirements of Section C403.1.1 shall be omitted. C409.6.1.1.1 Number of blocks. One or more blocks may be required per building based on the following restrictions: 1. Each block can have only one occupancy type (multifamily dwelling unit, multifamily common area, office, library, education, hotel/motel or retail). Therefore, at least one single block shall be created for each unique use type. 2. Each block can be served by only one type of HVAC system. Therefore, a single block shall be created for each unique HVAC system and use type combination. Multiple HVAC units of the same type may be represented in one block. Table D601.10.2 provides directions for combining multiple HVAC units or components of the same type into a single block. 3. Each block can have a single definition of floor to floor or floor to ceiling heights. Where floor heights differ by more than two feet, unique blocks should be created for the floors with varying heights. 4. Each block can include either above grade or below grade floors. For buildings with both above grade and below grade floors, separate blocks should be created for each. For buildings with floors partially above grade and partially below grade, if the total wall area of the floor(s) in consideration is greater than or equal to 50 percent above grade, then it should be simulated as a completely above grade block, otherwise it should be simulated as a below grade block. 5. Each wall on a facade of a block shall have similar vertical fenestration. The product of the proposed design U-factor times the area of windows (UA) on each facade of a given floor cannot differ by more than 15 percent of the average UA for that facade in each block. The product of the proposed design SHGC times the area of windows (SHGCA) on each facade of a given floor cannot differ by more than 15 percent of the average SHGCA for that facade in each block. If either of these conditions are not met, additional blocks shall be created consisting of floors with similar fenestration. 6. For a building model with multiple blocks, the blocks should be configured together to have the same adjacencies as the actual building design. C409.6.1.2 Thermal zoning. Each floor in a block shall be modeled as a single thermal zone or as five thermal zones consisting of four perimeter zones and a core zone. Below grade floors shall be modeled as a single thermal block. If any facade in the block is less than 45 feet in length, there shall only be a single thermal zone per floor. Otherwise each floor shall be modeled with five thermal zones. A perimeter zone shall be created extending from each facade to a depth of 15 feet. Where facades intersect, the zone boundary shall be formed by a 45 degree angle with the two facades. The remaining area or each floor shall be modeled as a core zone with no exterior walls. C409.6.1.3 Occupancy. C409.6.1.3.1 Occupancy type. The occupancy type for each block shall be consistent with the building area type as determined in accordance with C405.4.2.1. Portions of the building that are building area types other than multifamily dwelling unit, multifamily common area, office, school (education), library, or retail shall not be included in the simulation. Surfaces adjacent to such building portions shall be modeled as adiabatic in the simulation program. C409.6.1.3.2 Occupancy schedule, density, and heat gain. The occupant density, heat gain, and schedule shall be for multifamily, office, retail, library, hotel/motel or school as specified by ASHRAE Standard 90.1 Normative Appendix C. C409.6.1.4 Envelope components. C409.6.1.4.1 Roofs. Roofs will be modeled with insulation above a steel roof deck. The roof U-factor and area shall be modeled as in the proposed design. If different roof thermal properties are present in a single block, an area weighted U-factor shall be used. Roof solar absorptance shall be modeled at 0.70 and emittance at 0.90. C409.6.1.4.2 Above grade walls. Walls will be modeled as steel frame construction. The U-factor and area of above grade walls shall be modeled as in the proposed design. If different wall constructions exist on the facade of a block an area-weighted U-factor shall be used. C409.6.1.4.3 Below grade walls. The C-factor and area of below grade walls shall be modeled as in the proposed design. If different slab on grade floor constructions exist in a block, an area-weighted C- factor shall be used. C409.6.1.4.4 Above grade exterior floors. Exterior floors shall be modeled as steel frame. The U-factor and area of floors shall be modeled as in the proposed design. If different wall constructions exist in the block an area-weighted U-factor shall be used. C409.6.1.4.5 Slab on grade floors. The F-factor and area of slab on grade floors shall be modeled as in the proposed design. If different below grade wall constructions exist in a block, an area-weighted F- factor shall be used. C409.6.1.4.6 Vertical fenestration. The window area and area weighted U-factor and SHGC shall be modeled for each facade based the proposed design. Each exterior surface in a block must comply with Section D601.2.1 item 5. Windows will be combined into a single window centered on each facade based on the area and sill height input by the user. When different U values, SHGC or sill heights exist on a single facade, area weighted average for each shall be input by the user. C409.6.1.4.7 Skylights. The skylight area and area weighted U-factor and SHGC shall be modeled for each floor based the proposed design. Skylights will be combined in to a single skylight centered on the roof of each zone based on the area input by the user C409.6.1.4.8 Exterior Shading. Permanent window overhangs shall be modeled. When windows with and without overhangs or windows with different overhang projection factors exist on a facade, window width weighted projection factors shall be input by the user in accordance with equation 4-19. [image omitted; see the official code] Equation 4-19 Where, P avg = Average overhang projection modeled in the simulation tool A = Distance measured horizontally from the furthest continuous extremity of any overhang, eave, or permanently attached shading device to the vertical surface of the glazing. L o = Length off the overhang L w = Length of the window C409.6.1.5 Lighting. Interior lighting power density shall be equal to the allowance in Table C405.4.2(1) for multifamily, office, retail, library, or school. The lighting schedule shall be for multifamily, office, retail, library, or school as specified by ASHRAE Standard 90.1 Normative Appendix C. The impact of lighting controls is assumed to be captured by the lighting schedule and no explicit controls shall be modeled. Exterior lighting shall not be modeled. C409.6.1.6 Miscellaneous equipment. The miscellaneous equipment schedule and power shall be for multifamily, office, retail, library, or school as specified by ASHRAE Standard 90.1 Normative Appendix C. The impact of miscellaneous equipment controls is assumed to be captured by the equipment schedule and no explicit controls shall be modeled. Exceptions. 1. Multifamily dwelling units shall have a miscellaneous load density of 0.42 W/ft 2 2. Multifamily common areas shall have a miscellaneous load density of 0 W/ft 2 C409.6.1.7 Elevators. Elevators shall not be modeled. C409.6.1.8 Service water heating equipment. Service water heating shall not be modeled. C409.6.1.9 On-site renewable energy systems. On-site Renewable Energy Systems shall not be modeled. C409.6.1.10 HVAC equipment. HVAC systems shall meet the requirements of Section C403 Mechanical Systems. C409.6.1.10.1 Supported HVAC systems. At a minimum, the HVAC systems shown in Table C409.6.1.10.1 shall be supported by the simulation program. Table C409.6.1.10.1 PROPOSED BUILDING HVAC SYSTEMS SUPPORTED BY HVAC TSPR SIMULATION SOFTWARE System No. | System Name | System Abbreviation 1 | Packaged Terminal Air Conditioner | PTAC 2 | Packaged Terminal Air Heat Pump | PTHP 3 | Packaged Single Zone Gas Furnace | PSZGF 4 | Packaged Single Zone Heat Pump (air to air only) | PSZHP 5 | Variable Refrigerant Flow (air cooled only) | VRF 6 | Four Pipe Fan Coil | FPFC 7 | Water Source Heat Pump | WSHP 8 | Ground Source Heat Pump | GSHP 9 | Packaged Variable Air Volume (DX cooling) | PVAV 10 | Variable Air Volume (hydronic cooling) | VAV 11 | Variable Air Volume with Fan Powered Terminal Units | VAVFPTU 12 | Dedicated Outdoor Air System (in conjunction with systems 1-8) | DOAS C409.6.1.10.2 Proposed building HVAC system simulation.The HVAC systems shall be modeled as in the proposed design with clarifications and simplifications as described in Tables C409.6.1.10.2(1) and C409.6.1.10.2(2). System parameters not described in the following sections shall be simulated to meet the minimum requirements of Section C403. All zones within a block shall be served by the same HVAC system type as described in Section C409.6.1.1.1 item 2. Heat loss from ducts and pipes shall not be modeled. For packaged single-zone air conditioners (cooling only), water-loop heat pumps, ground-source heat pumps and packaged rooftop heat pumps, heating COP and cooling COP, exclusive of fan power, shall be determined using the following equations: Equation 4 20 - For Table C409.6.1.10.1 Systems 4, 7, and 8 heating efficiency COP nfheating = 1.48E-7 x COP 47 x Q + 1.062 x COP 47 Equation 4-21 - For Table C409.6.1.10.1 System 3 heating efficiency COP nfheating 0.0296 x HSPF 2 + 0.7134 x HSPF Equation 4-22 - For Table C409.6.1.10.1 System 4, 7, 8, and 9 cooling efficiency COP nfcooling = 7.84E-8 x EER x Q + 0.338 x EER Equation 4-23 - For Table C409.6.1.10.1 System 1 and 2 cooling efficiency COP nfcooling = -0.0076 x SEER 2 + 0.3796 x SEER Equation 4-24 - For Table C409.6.1.10.1 System 1 and 2 cooling efficiency COP nfcooling = 0.3322 x EER - 0.2145 Equation 4-25 - For Table C409.6.1.10.1 System 2 heating efficiency COP nfheating = 1.1329 x COP - 0.214 Where: EER, SEER, COP and HSPF shall be at AHRI full load test conditions Q = AHRI rated cooling capacity in BTU/h. If Q > 760,000BTU/h use 760,000 in the calculation Where multiple system components serve a block, average values weighed by the appropriate metric as described in this section shall be used. 1. Where multiple fan systems serve a single block, fan power shall be based on weighted average using the design supply air cfm 2. Where multiple cooling systems serve a single block, COP shall be based on a weighted average using cooling capacity. DX coils shall be entered as multi-stage if more than 50% of coil capacity serving the block is multi-stage with staged controls. 3. Where multiple heating systems serve a single block, thermal efficiency or heating COP shall be based on a weighted average using heating capacity. 4. Where multiple boilers or chillers serve a heating water or chilled water loop, efficiency shall be based on a weighted average for using heating or cooling capacity. 5. When multiple cooling towers serving a condenser water loop are combined, the cooling tower efficiency, cooling tower design approach and design range are based on a weighted average of the design water flow rate through each cooling tower. 6. Where multiple pumps serve a heating water, chilled water or condenser water loop pump power shall be based on a weighted average for using design water flow rate. 7. When multiple system types with and without economizers are combined, the economizer maximum outside air fraction of the combined system shall be based on weighted average of 100% supply air for systems with economizers and design outdoor air for systems without economizers. 8. Multiple systems with and without ERVs cannot be combined. 9. Systems with and without supply air temperature reset cannot be combined. 10. Systems with different fan control (constant volume, multi-speed or VAV) for supply fans cannot be combined. C409.6.1.10.3 Demand Control Ventilation. Demand Controlled Ventilation (DCV) shall be modeled using a simplified approach that adjusts the design outdoor supply air flow rate based on the area of the building that is covered by DCV. TABLE C409.6.1.10.2(1) PROPOSED BUILDING SYSTEM PARAMETERS Category | Parameter | Fixed or User Defined | Required | Applicable Systems HVAC System Type | System Type | User Defined | Selected from Table C409.6.1.10.1 | All System Sizing | Design Day Information | Fixed | 99.6% heating design and 1% dry-bulb and 1% wet-bulb cooling design | All Zone Coil Capacity | Fixed | Sizing factors used are 1.25 for heating equipment and 1.15 for cooling equipment | All Supply Airflow | Fixed | Based on a supply-air-to-room-air temperature set-point difference of 20°F or | 1-11 Fixed | Equal to required outdoor air ventilation | 12 Outdoor Ventilation Air | Portion of supply air with proposed Filter 2MERV 13 | User-defined | Percentage of supply air flow subject to higher filtration (Adjusts baseline Fan Power higher. Prorated) | All Outdoor Ventilation Air Flow Rate | Fixed | As specified in ASHRAE Standard 90.1 Normative Appendix C, adjusted for proposed DCV control | All Outdoor Ventilation Supply Air Flow Rate Adjustments | Fixed | Based on ASHRAE Standard 62.1 Section 6.2.4.3 System Ventilation Efficiency (Evs) is 0.75 | 9-11 Fixed | System Ventilation Efficiency (Evs) is 1.0 | 1-8, 12 Fixed | Basis is 1.0 Zone Air Distribution Effectiveness | All System Operation | Space temperature Set points | Fixed | As specified in ASHRAE Standard 90.1 Normative Appendix C, except multifamily which shall use 68 deg. F heating and 76 deg. F cooling setpoints | 1-11 Fan Operation - Occupied | User Defined | Runs continuously during occupied hours or cycles to meet load. Multispeed fans reduce airflow related to thermal loads. | 1-11 Fan Operation - Occupied | Fixed | Fan runs continuously during occupied hours | 12 Category | Parameter | Fixed or User Defined | Required | Applicable Systems Fan Operation - Night Cycle | Fixed | Fan cycles on to meet setback temperatures | 1-11 Packaged Equipment Efficiency | DX Cooling Efficiency | User Defined | Cooling COP without fan energy calculated in accordance with Section C409.6.1.10.2 | 1, 2, 3, 4, 5, 7, 8, 9, 11, 12 DX Coil Number of Stages | User-defined | Single Stage or Multistage | 3, 4, 9 Heat Pump Efficiency | User Defined | Heating COP without fan energy calculated in accordance with Section C409.6.1.10.2 | 2, 4, 5, 7, 8 Furnace Efficiency | User Defined | Furnace thermal efficiencyc | 3, 11 Heat Pump Supplemental Heat | Control | Fixed | Supplemental electric heat locked out above 40°F. Runs In conjunction with compressor between 40°F and 0°F. | 2, 4 System Fan Power and Controls | Part-load Fan Controls | User-defined | Constant volume or two speed | 1-8 Part-load Fan Controls a | User-defined | Constant volume or variable air volume | 12 Part-load Fan Controls a | Fixed | Variable air volume. VFD with static pressure reset | 9-11 Design Fan Power (W/cfm) | User Defined | Input electric power for all fans in required to operate at fan system design conditions divided by the supply airflow rate This is a "wire to air" value including all drive, motor efficiency and other losses. | All Low-speed fan power | User Defined | Low speed input electric power for all fans required to operate at low speed conditions divided by the low speed supply airflow rate. This is a "wire to air" value including all drive, motor efficiency and other losses. | 1-8 Variable Air Volume Systems | Supply Air Temperature (SAT) Controls | User defined | If not SAT reset then constant at 55°F. Options for reset based on outside air temperature (OAT) or warmest zone. If warmest zone, then the user can specify the minimum and maximum temperatures. If OAT reset, SAT is reset higher to 60°F at outdoor low of 50°F. SAT is 55°F at outdoor high of 70°F. | 9, 10, 11 Minimum Terminal Unit airflow percentage | User Defined | Average minimum terminal unit airflow percentage for block weighted by cfm or minimum required for outdoor air ventilation, whichever is higher. | 9, 10, 11 Terminal Unit Heating Source | User Defined | Electric or hydronic | 9, 10, 11 Dual set point minimum VAV damper position | User-defined | Heating maximum airflow fraction | 9, 10. Fan Powered Terminal Unit (FPTU) Type | User Defined | Series or parallel FPTU | 11 Parallel FPTU Fan | Fixed | Sized for 50% peak primary air at 0.35 W/cfm | 11 Series FPTU Fan | Fixed | Sized for 50% peak primary air at 0.35 W/cfm | 11 Economizer | Economizer Presence | User Defined | Yes or No | 3, 4, 9, 10, 11 Economizer Control Type | Fixed | Differential dry-bulb | 3, 4, 9, 10, 11 Energy Recovery | Sensible Effectiveness | User Defined | Heat exchanger sensible effectiveness at design heating and cooling conditions | 3, 4, 9, 10, 11, 12 Latent Effectiveness | User Defined | Heat exchanger latent effectiveness at design heating and cooling conditions | 3, 4, 9, 10, 11, 12 Economizer Bypass | User Defined | If ERV is bypassed during economizer conditions | 3, 4, 9, 10, 11, 12 Bypass SAT Setpoint | User Defined | If bypass, target supply air temperature | 3, 4, 9, 10, 11, 12 Fan Power Reduction during Bypass (W/cfm) | User Defined | If ERV system include bypass, static pressure set point and variable speed fan, fan power can be reduced during economizer conditions | 3, 4, 9, 10, 11, 12 Demand Controlled Ventilation | DCV Application | User Defined | Percent of block floor area under DCV control | 3, 4, 9, 10, 11, 12 DOAS | DOAS Fan Power W/cfm | User Defined | Fan electrical input power in W/cfm of supply airflowa | 12 DOAS Supplemental Heating and Cooling | User Defined | Heating source, cooling source | 12 Maximum SAT Set point (Cooling) | User-defined | SAT set point if DOAS includes supplemental cooling | 12 Minimum SAT Set point (Heating) | User-defined | SAT set point if DOAS includes supplemental heating | 12 Heating Plant | Boiler Efficiency | User Defined | Boiler thermal efficiency | 1, 6, 7, 9, 10, 11, 12 Heating Water loop Configuration a | User-defined | Constant flow primary only; Variable flow primary only; Constant flow primary - variable flow secondary | 1, 6, 7, 9, 10, 11, 12 Heating Water Primary Pump Power (W/gpm) | User-defined | Heating water primary pump input W/gpm heating water flow | 1, 6, 7, 9, 10, 11, 12 Heating Water Secondary Pump Power (W/gpm) | User-defined | Heating water secondary pump input W/gpm heating water flow (if primary/secondary) | 1, 6, 7, 9, 10, 11, 12 Heating Water Loop Temperature | Fixed | 180°F supply, 130°F return | 1, 6, 9, 10, 11 Boiler Type | Fixed | Non-condensing boiler where input thermal efficiency is less than 86%; Condensing boiler otherwise | 1, 6, 7, 9, 10, 11, 12 Chilled Water Plant | Chiller Compressor Type | User Defined | Screw/Scroll, Centrifugal or Reciprocating | 6, 10, 11, 12 Chiller Condenser Type | User Defined | Air cooled or water cooled | 6, 10, 11, 12 Chiller Full Load Efficiency | User Defined | Chiller COP | 6, 10, 11, 12 Chilled Water loop Configuration a | User Defined | Variable flow primary only, constant flow primary - variable flow secondary | 6, 10, 11, 12 Chilled Water Primary Pump Power (W/gpm) | User-defined | Primary pump input W/gpm chilled water flow | 6, 10, 11, 12 Chilled Water Secondary Pump Power (W/gpm) | User-defined | Secondary Pump input W/gpm chilled water flow (if primary/secondary) | 6, 10, 11, 12 Chilled Water Temperature Reset Included | User Defined | Yes/No | 6, 10, 11, 12 Chilled Water Plant (cont.) | Chilled Water Temperature Reset Schedule (if included) | Fixed | Outdoor air reset: CHW supply temperature of 44°F at 80°F outdoor air dry bulb and above. CHW supply temperature of 54°F at 60°F outdoor air dry bulb temperature and below, ramped linearly between | 6, 10, 11, 12 Condenser Water Pump Power (W/gpm) | User Defined | Pump input W/gpm condenser water flow | 6, 7, 8, 10, 11, 12 Condenser Water Pump Control | User Defined | Constant speed or variable speed | 6, 7, 8, 10, 11, 12 Cooling Tower Efficiency | User Defined | gpm/hp tower fan | 6, 7, 10, 11, 12 Cooling Tower Fan Control | User Defined | Constant or variable speed | 6, 7, 10, 11, 12 Cooling Tower Approach and Range | User Defined | Design cooling tower approach and range temperature | 6, 7, 10, 11, 12 Heat Pump Loop Flow Control | Loop flow and Heat Pump Control Valve | Fixed | Two position Valve with VFD on Pump. Loop flow at 3 gpm/ton | 7, 8 Heat Pum Loop Temperature Control | Fixed | Set to maintain temperature between 50°F and 70°F | 7 GLHP Well Field | Fixed | Bore depth = 250' Bore length 200'/ton for greater of cooling or heating load Bore spacing = 15' Bore diameter = 5" ¾" Polyethylene pipe Ground and grout conductivity = 4.8 Btu-in/h-ft2-OF | 8 Category | Parameter | Fixed or User Defined | Required | Applicable Systems Fan Power Reduction during Bypass (W/cfm) | User Defined | If ERV system include bypass, static pressure set point and variable speed fan, fan power can be reduced during economizer conditions | 3, 4, 9, 10, Demand Controlled Ventilation | DCV Application | User Defined | Percent of block floor area under DCV control | 3, 4, 9, 10, 11, 12 DOAS | DOAS Fan Power W/cfm | User Defined | Fan electrical input power in W/cfm of supply airflowa | 12 DOAS Supplemental Heating and Cooling | User Defined | Heating source, cooling source | 12 Maximum SAT Set point (Cooling) | User-defined | SAT set point if DOAS includes supplemental cooling | 12 Minimum SAT Set point (Heating) | User-defined | SAT set point if DOAS includes supplemental heating | 12 Heating Plant | Boiler Efficiencyd | User Defined | Boiler thermal efficiency | 1, 6, 7, 9, 10, 11, 12 Heating Water loop Configuration a | User-defined | Constant flow primary only; Variable flow primary only; Constant flow primary - variable flow secondary | 1, 6, 7, 9, 10, 11, 12 Heating Water Primary Pump Power (W/gpm) | User-defined | Heating water primary pump input W/gpm heating water flow | 1, 6, 7, 9, 10, 11, 12 Heating Water Secondary Pump Power (W/gpm) | User-defined | Heating water secondary pump input W/gpm heating water flow (if primary/secondary) | 1, 6, 7, 9, 10, 11, 12 Heating Water Loop Temperature | Fixed | 180°F supply, 130°F return | 1, 6, 9, 10, 11 Boiler Type | Fixed | Non-condensing boiler where input thermal efficiency is less than 86%; Condensing boiler otherwise | 1, 6, 7, 9, 10, 11, 12 Chilled Water Plant | Chiller Compressor Type | User Defined | Screw/Scroll, Centrifugal or Reciprocating | 6, 10, 11, 12 Chiller Condenser Type | User Defined | Air cooled or water cooled | 6, 10, 11, 12 Chiller Full Load Efficiencyd | User Defined | Chiller COP | 6, 10, 11, 12 Chilled Water loop Configuration a | User Defined | Variable flow primary only, constant flow primary - variable flow secondary | 6, 10, 11, 12 Chilled Water Primary Pump Power (W/gpm) | User-defined | Primary pump input W/gpm chilled water flow | 6, 10, 11, 12 Chilled Water Secondary Pump Power (W/gpm) | User-defined | Secondary Pump input W/gpm chilled water flow (if primary/secondary) | 6, 10, 11, 12 Chilled Water Temperature Reset Included | User Defined | Yes/No | 6, 10, 11, 12 Chilled Water Plant (cont.) | Chilled Water Temperature Reset Schedule (if included) | Fixed | Outdoor air reset: CHW supply temperature of 44°F at 80°F outdoor air dry bulb and above, CHW supply temperature of 54°F at 60°F outdoor air dry bulb temperature and below, ramped linearly between | 6, 10, 11, 12 Condenser Water Pump Power (W/gpm) | User Defined | Pump input W/gpm condenser water flow | 6, 7, 8, 10, 11, 12 Condenser Water Pump Control | User Defined | Constant speed or variable speed | 6, 7, 8, 10, 11, 12 Cooling Tower Efficiency | User Defined | gpm/hp tower fan | 6, 7, 10, 11, 12 Cooling Tower Fan Control | User Defined | Constant or variable speed | 6, 7, 10, 11, 12 Cooling Tower Approach and Range | User Defined | Desipn cooling tower approach and range temperature | 6, 7, 10, 11, 12 Heat Pump Loop Flow Control | Loop flow and Heat Pump Control Valve | Fixed | Two position Valve with VFD on Pump. Loop flow at 3 gpm/ton | 7, 8 Heat Pump Loop | Fixed | Set to maintain temperature between 50°F and 70°F | 7 Temperature Control GLHP Well Field | Fixed | Bore depth = 250' Bore length 200'/ton for greater of cooling or heating load Bore spacing = 15' Bore diameter = 5" ¾" Polyethylene pipe Ground and grout conductivity = 4.8 Btu-in/h-ft2-OF | 8 a. Part load fan power and pump power modified in accordance with Table C409.6.1.10.2(2) Table C409.6.1.10.2(2) Fan and Pump Power Curve Coefficients Equation Term | Fan Power Coefficients | Pump Power Coefficients VSD + SP reset | Ride Pump Curve | VSD + DP/valve reset b | 0.0013 | 0.0408 | 0 | 0 x | 0.147 | 0.088 | 3.2485 | 0.0205 x 2 | 0.9506 | -0.0729 | -4.7443 | 0.4101 x 3 | -0.0998 | 0.9437 | 2.5295 | 0.5753 C409.6.2 Simulation of the standard reference design. The standard reference design shall be configured and analyzed as specified in this section. C409.6.2.1 Utility rates. Same as proposed. C409.6.2.2 Blocks. Same as proposed. C409.6.2.3 Thermal zoning. Same as proposed. C409.6.2.4 Occupancy type, schedule, density, and heat gain. Same as proposed. C409.6.2.5 Envelope components. Same as proposed. C409.6.2.6 Lighting. Same as proposed. C409.6.2.7 Miscellaneous equipment. Same as proposed. C409.6.2.8 Elevators. Not modeled. Same as proposed. C409.6.2.9 Service water heating equipment. Not modeled. Same as proposed. C409.6.2.10 On-site renewable energy systems. Not modeled. Same as proposed. C409.6.2.11 HVAC equipment. The reference building design HVAC equipment consists of separate space conditioning systems as described in Table C409.6.2.11(1) through Table C409.6.2.11(3) for the appropriate building use types. Table C409.6.2.11(1) Reference Building Design HVAC Complex Systems Building Type Parameter | Large Office | School System Type | VAV/ RH Water-cooled Chiller/Gas Boiler | VAV/RH Water-cooled Chiller/Gas Boiler Fan control | VSD (no SP Reset) | VSD (no SP Reset) Main fan power (W/CFM (W·s/L) 3 roposed 2 MERV13 | 1.165 (2.468) | 1.165 (2.468) Main fan power (W/CFM (W·s/L) proposed < MERV13 | 1.066 (2.259) | 1.066 (2.259) Zonal fan power (W/CFM (W·s/L)) | NA | NA Minimum zone airflow fraction | 1.5* Voz | 1.2* Voz Heat/cool sizing factor | 1.25/1.15 | 1.25/1.15 Ourtdoor air economizer | Yes except 4A | Yes except 4A Occupied OSA (= proposed) | Sum(Voz)/0. 75 | Sum(Voz)/0.65 Energy recovery ventilator efficiency ERR (Enthalpy Recovery Ratio) ERV bypass SAT set point | NA | 50% 60°F except 4A DCV | No | No Cooling Source | (2) Water-cooled Centrifugal Chillers | (2) Water- Cooled Screw Chillers Cooling COP (net of fan) | Path B for profile | Path B for profile Heating source (reheat) | Gas Boiler | Gas Boiler Furnace or boiler efficiency | 75% Et | 80% Et Condenser heat rejection | Cooling Tower | Cooling Tower Cooling tower efficiency (gpm/fan-hp (L/s·fan-kW)) | 38.2 (3.23) | 38.2 (3.23) Tower turndown (> 300 ton (1060 kW)) | 50% | 50% Pump (constant flow/variable flow) | Constant Flow; 10°F (5.6°C) range | Constant Flow; 10°F (5.6°C) range Tower approach | 25.72 - (0.24 x WB), where WB WB is the 0.4% evaporation design wet-bulb temperature (°F) Cooling condenser pump power (W/gpm (W·s/L)) | 19 (300) | 19 (300) Cooling primary pump power (W/gpm (W·s/L)) | 9 (142) | 9 (142) Cooling secondary pump power (W/gpm (W·s/L)) | 13 (205) | 13 (205) Cooling coil chilled water delta-T, °F (°C) | 12 (6.7) | 12 (6.7) Design chilled water supply temperature, °F (°C) | 44 (6.7) | 44 (6.7) Chilled water supply temperature (CHWST) reset set point vs OAT, °F (°C) | CHWST/OAT: 44-54/ 80-60 (6.7-12.2/26.7-15.6) | CHWST/OAT: 44-54/ 80-60 (6.7-12.2/26.7-15.6) CHW cooling loop pumping control | 2-way Valves & pump VSD | 2-way Valves & pump VSD Heating pump power (W/gpm (W·s/L)) | 16.1 (254) | 19(254) Heating oil HW dT. °F (°C) | 50(10) | 50(10) Design HWST. °F (°C) | 180 (82) | 180(82) HWST reset set point vs OAT, °F (°C) | HWST/OAT: 180-150/ 20-50 (82-65.6/-6.7-10) | HWST/OAT: 180-150/20-50 (82-65.6/ - 6.7-10) Heat loop pumping control | 2-way Valves & pump VSD | 2-way Valves & pump VSD Table C409.6.2.11(2) TSPR Reference Building Design HVAC Simple Systems Building Type Parameter | Medium Office | Small Office | Retail System type | Package VAV-Hydronic Reheat | PSZ-AC | PSZ-AC Fan control | VSD (no SP Reset) | Constant Volume | Constant Volume Main fan power (W/CFM (W·s/L)) proposed 2 MERV13 | 1.285 (2.723) | 0.916 (1.941) | 0.899 (1.905) Main fan power (W/CFM (W·s/L)) proposed < MERV13 | 1.176 (2.492) | 0.850 (1.801) | 0.835 (1.801) Zonal fan power (W/CFM (W·s/L)) | NA | NA | NA Minimum zone airflow fraction | 30% | NA | NA Heat/cool sizing factor | 1.25/1.15 | 1.25/1.15 | 1.25/1.15 Supplemental heating availability | NA | NA | NA Outdoor air economizer | Yes except 4A | Yes except 4A | Yes except 4A Occupied OSA source | Packaged unit, occupied damper, all building use types Energy recovery ventilator | No | No | No DCV | No | No | No Cooling source | DX, multi- stage | DX, single stage | DX, single stage Cooling COP (net of fan) | 3.40 | 3.00 | 3.50 Heating source | Gas Boiler | Furnace | Furnace Heating COP (net of fan) / furnace or boiler efficiency | 75% Et | 80% Et | 80% Et Table C409.6.2.11(3) TSPR Reference Building Design HVAC Simple Systems Building Type Parameter | Hotel | Multifamily System type | PTAC | PTAC Fan control | Constant Volume | Constant Volume Main fan power (W/CFM (W·s/L)) | 0.300 (0.636) | 10.300 (0.636) Heat/cool sizing factor | 1.25/1.15 | 1.25/1.15 Supplemental heating availability | NA | NA Outdoor air economizer | No | No Occupied OSA source | Packaged unit, occupied damper | Packaged unit, occupied damper Energy recovery ventilator | No | No DCV | No | No Cooling source | DX, 1 stage | DX, 1 stage Cooling COP (net of fan) | 3.20 | 3.20 Heating source | (2) Hydronic Boiler | (2) Hvdronic Boiler Heating COP (net of fan) / furnace or boiler efficiency | 75% Et | 75% Et Heating pump power (W/gpm (W·s/L)) | 19 (300) | 19 (300) Heating coil heating water delta-T, °F (°C) | 50 (27.8) | 50 (27.8) Design HWST, °F (°C) | 180 (82.2) | 180 (82.2) HWST reset set point vs OAT, °F (°C) | HWST/OAT: 180-150/20-50 (82-65.6/ -6.7-10) | HWST/OAT: 180/150 20/50 (82-65.6/ -6.7-10) Heat loop pumping control | 2-way Valves & ride pump curve | 2-way Valves & ride pump curve C409.7 Target Design HVAC Systems. Target system descriptions described in Tables C409.7(1) through C409.7(3) are provided as reference for Section C403.1.3 Exception 10. The target systems are used for developing MPF values and do not need to be programmed into TSPR software. Table C409.7(1) Target Building Design Criteria HVAC Complex Systems Building Type Parameter | Large Office | School System Type | VAV/RH | VAV/RH Water-cooled Chiller/ | Water-cooled Chiller/ Gas Boiler | Gas Boiler Fan control | VSD (with SP Reset) | VSD (with SP Reset) Main fan power (W/CFM (W·s/L) Proposed 2 MERV13 | 1.127 (2.388) | 1.127 (2.388) Zonal fan power (W/CFM (W·s/L)) | NA | NA Minimum zone airflow fraction | 1.5* Voz | 1.2* Voz Heat/cool sizing factor | 1.25/1.15 | 1.25/1.15 Outdoor air economizer | Yes | Yes Occupied OSA (= proposed) | Sum(Voz)/0.75 | Sum(Voz)/0.65 Energy recovery ventilator efficiency ERR | NA | 50% DCV | Yes | Yes % Area Variable Control | 15% | 70% % Area On/Off Control | 65% | 20% Cooling Source | (2) Water- cooled Centrif Chillers | (2) Water- Cooled Screw Chillers Cooling COP (net of fan) | Path B for profile | Path B for profile Heating source (reheat) | Gas Boiler | Gas Boiler Furnace or boiler efficiency | 90% Et | 80% Et Condenser heat rejection | Cooling Tower | Cooling Tower Cooling tower efficiency (gpm/hp (L/s·kW))—See G3.1.3.11 | 40.2 (3.40) | 40.2 (3.40) Tower turndown (> 300 ton (1060 kW)) | 50% | 50% Pump (constant flow/variable flow) | Constant Flow; 10°F (5.6°C) range | Constant Flow; 10°F (5.6°C) range Tower approach | G3.1.3.11 | G3.1.3.11 Cooling condenser pump power (W/gpm (W·s/L)) | 19 (300) | 19 (300) Cooling primary pump power (W/gpm (W·s/L)) | 9 (142) | 9 (142) Cooling secondary pump power (W/gpm (W·s/L)) | 13 (205) | 13 (205) Cooling coil chilled water delta-T, °F (°C) | 18 (10) | 18 (10) Design chilled water supply temperature, °F (°C) | 42 (5.56) | 42 (5.56) Chilled water supply temperature (CHWST) | CHWST/OAT: | CHWST/OAT: reset set point vs OAT, °F (°C) | 44-54/ 80-60 (6.7-12.2/ 26.7-15.6) (see Apx G) | 44-54/ 80-60 (6.7-12.2/ 26.7-15.6) (see Apx G) CHW cooling loop pumping control | 2-way Valves & pump VSD | 2-way Valves & pump VSD Heating pump power (W/gpm (W·s/L)) | 16.1 (254) | 19 (254) Heating HW dT. °F (°C) | 20 (11.11) | 20 (11.11) Design HWST. °F (°C) | 140 (60) | 140 (60) HWST reset set point | HWST/OAT: 180-150/20-50 (82-65.6/ -6.7-10) | HWST/OAT: 180-150/20-50 (82-65.6/-6.7-10) vs OAT, °F (°C) Heat loop pumping control | 2-way Valves & pump VSD | 2-way Valves & pump VSD Table C409.7(2) Target Building Design Criteria HVAC Simple Systems Building Type | Medium Office | Small Office | Retail System type | Package VAV - Hydronic Reheat | PSZ-AC | PSZ-AC Fan control | VSD (with SP Reset) | Constant Volume | 2-speed Main fan power (W/CFM (W·s/L)) | 0.634 (1.343) | 0.486 (1.03) | 0.585 (1.245) SURSRVHG · 0(59 Zonal fan power (W/CFM (W·s/L)) | NA | NA | NA Minimum zone airflow fraction | 1.5* Voz | NA | NA Heat/cool sizing factor | 1.25/1.15 | 1.25/1.15 | 1.25/1.15 Supplemental heating availability | NA | NA | NA Outdoor air economizer | Yes | Yes | Yes Occupied OSA source | Packaged unit, occupied damper, all building use types Energy recovery ventilator | No | No | Yes all A, 6,7,8 CZ ERR | 50% DCV | Yes | No | Yes % Area Variable Control | 15% | 80% % Area On/Off Control | 65% | 0% Cooling source | DX, multi- stage | DX, single stage | DX, 2 stage Cooling COP (net of fan) | 3.83 | 3.8248 | 3.765 Heating source | Gas Boiler | Furnace | Furnace Heating COP (net of fan) / furnace or boiler efficiency | 81% Et | 81% Et | 81% Et Heating coil HW dT. °F (°C) | 20 (11.11) | NA | NA Design HWST. °F (°C) | 140 (60) | NA | NA HWST reset set point | HWST/OAT:180-150/20-50 (82-65.6/ -6.7-10) | NA | NA vs OAT, °F (°C) Heat loop pumping control | 2-way Valves & ride pump curve | NA | NA Heating pump power (W/gpm (W·s/L)) | 16.1 | NA | NA Table C409.7(3) Target Building Design Criteria HVAC Simple Systems Building Type | Hotel | Multifamily Parameter System type | PTAC with Hydronic Boiler | Split AC Fan control | Cycling | Cycling Main fan power (W/CFM (W·s/L)) | 0.300 (0.638) | 0.271 (0.576) Heat/cool sizing factor | 1.25/1.15 | 1.25/1.15 Supplemental heating availability | NA | NA Outdoor air economizer | No | No Occupied OSA source | DOAS | DOAS except 3C Energy recovery ventilator | NA | Yes except 3C DCV | Yes | No % Area Variable Control | 70% % Area On/Off Control | 0% Cooling source | DX, 1 stage | DX, 1 stage Cooling COP (net of fan) | 3.83 | 3.6504 Heating source | (2) Hydronic Boiler | Furnace Heating COP (net of fan) / furnace or boiler efficiency | 81% Et | 80% AFUE Heating pump power (W/gpm (W·s/L)) | 16.1 | NA Heating coil heating water delta-T, °F (°C) | 20 (11.11) | NA Design HWST, °F (°C) | 140 (60) | NA HWST reset set point | HWST/OAT: 180-150/20-50 (82-65.6/ -6.7-10) | NA vs OAT, °F (°C) Heat loop pumping control | 2-way Valves & ride pump curve | NA Chapter 6 of the IECC is amended to add the following: CTA | Consumer Technology Association 1919 S. Eads Street Arlington, VA 22202 Standard reference number | Title | Referenced in code section number ANSI/CTA-2045-B | Modular Communications Interface for Energy Management....... | ....... C404.11 Section R101.1 of the IECC is amended to read as follows: R101.1 Title. This code shall be known as the Energy Conservation Code of the City of Rockville, and shall be cited as such. It is referred to herein as "this code". Section R101.3 of the IECC is amended to read as follows: R101.3 Intent. This code shall regulate the design, and construction of buildings for the reduction of greenhouse gas emissions and for the efficient production, use and storage of energy over the useful life of each building. This code is intended to provide flexibility to permit the use of innovative approaches and techniques to achieve this objective. This code is not intended to abridge safety, health or environmental requirements contained in other applicable codes or ordinances. Section R102.1.1 of the IECC is amended to read as follows: R102.1.1 Above code programs. The Building Official or other authority having jurisdiction shall be permitted to deem a national, state or local energy efficiency program to exceed the energy efficiency required by this code if the program provides a detailed written energy analysis study demonstrating that the requirements in the program exceed all requirements of this code and includes a requirement for inspections of each building by an accredited independent party to determine compliance. Buildings approved in writing by such an energy efficiency program and that meet all mandatory provisions of this Article shall be considered in compliance with this code. Sections R301.2, R301.3 and R301.4 of the IECC are deleted. Section R103.2 of the IECC is amended to read as follows: R103.2 Information on construction documents. Construction documents shall be drawn to scale on suitable material. Electronic media documents are permitted to be submitted where approved by the code official. Construction documents shall be of sufficient clarity to indicate the location, nature and extent of the work proposed, and show in sufficient detail pertinent data and features of the building, systems and equipment as herein governed. Details shall include the following as applicable: 1. Energy compliance path. 2. Insulation materials and their R-values. 3. Fenestration U-factors and solar heat gain coefficients (SHGC). 4. Area-weighted U-factor and solar heat gain coefficients (SHGC) calculations. 5. Mechanical system design criteria. 6. Mechanical and service water heating systems and equipment types, sizes, fuel sources and efficiencies. 7. Equipment and system controls. 8. Duct sealing, duct and pipe insulation and location. 9. Air sealing details. 10. Energy Code Compliance Checklist. Section R103.2.2 of the IECC is added to read as follows: R103.2.2 Solar-ready system. The construction documents shall provide details for dedicated roof area, structural design for roof dead and live load, and routing of conduit or pre-wiring from solar-ready zone to electrical service panel or plumbing from solar-ready zone to service water heating system. Section R103.2.3 of the IECC is added to read as follows: R103.2.3 Energy storage-ready system. The construction documents shall provide the location of pathways for routing of raceways or cable from the electrical service panel and energy storage system area and the location and layout of a designated area for electrical energy storage system. Section R103.2.4 of the IECC is added to read as follows: R103.2.4 Electrification system. The construction documents shall provide details for additional electric infrastructure, including branch circuits, conduit, or pre-wiring, and panel capacity in compliance with the provisions of this code. Section R104.2 of the IECC is amended to read as follows: R104.2 Schedule of Permit Fees. A fee for each permit shall be paid as required, in accordance with the schedule as established by resolution of the Mayor and Council. Sections R104.3, R104.4 and R104.5 of the IECC are deleted. Section R105.2.5 of the IECC is amended to read as follows: R105.2.5 Electrical rough-in inspection. Inspections at electrical rough-in shall verify compliance as required by the code and the approved plans and specifications as to the locations, distribution, and capacity of the electrical system. Where the solar-ready zone is installed for electricity generation, inspections shall verify conduit or pre-wiring from solar-ready zone to electrical panel. Where the energy storage system area is not in the same space as the electrical panel, inspections shall verify conduit or pre-wiring from the energy storage ready zone to the electrical panel. Section R105.2.6 is added to the IECC to read as follows: R105.2.6 Final Inspection. The building shall have a final inspection and shall not be occupied until approved. The final inspection shall include verification of the installation of all required building systems, equipment and controls and their proper operation and the required number of high-efficacy lamps and fixtures. Section R108.1.1 of the IECC is amended to read as follows: R108.1.1 Conflicts. Where conflicts occur between provisions of this code and referenced codes and standards, the most restrictive provisions shall apply. Section R109 of the IECC is amended to read as follows: R109.1 Board of Adjustments and Appeals. Appeals of administrative interpretations or decisions made by the Building Official shall be administered in accordance with Chapter 5, Article I, Section 5-12 of the Rockville City Code. Section R202 of the IECC is amended to add new definitions as follows: ALL-ELECTRIC BUILDING. A building that contains no combustion equipment, or plumbing for combustion equipment, installed within the building, or building site. APPLIANCE. A device or apparatus that is manufactured and designed to utilize energy and for which this code provides specific requirements. COMBUSTION EQUIPMENT. Any equipment or appliance used for space heating, service water heating, cooking, clothes drying, or lighting that uses fuel gas or fuel oil. DEMAND RESPONSIVE CONTROL. An automatic control that can receive and automatically respond to demand response requests from a utility, electrical system operator, or third-party demand response program provider. ELECTRIC VEHICLE (EV). An automotive-type vehicle for on-road use, such as passenger automobiles, buses, trucks, vans, neighborhood electric vehicles, electric motorcycles, and the like, primarily powered by an electric motor that draws current from a rechargeable storage battery, a fuel cell, a photovoltaic array, or another source of electric current. Plug-in hybrid electric vehicles are electric vehicles having a second source of motive power. Off-road, self-propelled electric mobile equipment, such as industrial trucks, hoists, lifts, transports, golf carts, airline ground support equipment, tractors, boats and the like, are not considered electric vehicles. ELECTRIC VEHICLE SUPPLY EQUIPMENT (EVSE). The conductors, including the ungrounded, grounded, and equipment grounding conductors and the electric vehicle connectors, attachment plugs, and all other fittings, devices, power outlets, or apparatus installed specifically for the purpose of transferring energy between the premises wiring and the electric vehicle. EQUIPMENT. Piping, ducts, vents, control devices and other components of systems other than appliances that are permanently installed and integrated to provide control of environmental conditions for buildings. This definition shall also include other systems specifically regulated in this code. EV-READY SPACE. A parking space that has electrical panel capacity and full circuit installation of a minimum 40-ampere, 208/240-volt circuit raceway wiring, a NEMA 14-50r receptacle, and circuit overcurrent protection devices. EVSE-INSTALLED PARKING SPACE. A parking space with electric vehicle supply equipment that is fully installed from the electrical panel to the parking space. FUEL GAS. A natural gas, manufactured gas, liquified petroleum gas or a mixture of these. FUEL OIL. Kerosene or any hydrocarbon oil having a flash point not less than 100°F (38°C). LEVEL 2 CHARGING. The charging capability of the electric vehicle supply equipment includes the ability to charge a battery or any other energy storage device in an electric vehicle through means of an alternating current electric service with a minimum of 208 volts and meets applicable industry safety standards. MIXED-FUEL BUILDING. A building that contains combustion equipment or includes piping for combustion equipment. SOLAR-READY ZONE. A section or sections of the roof or building overhang designated and reserved for the future installation of a solar photovoltaic or solar thermal system. Section R301.1 of the IECC is amended to read as follows: R301.1 General. Climate zone "4A except Marine" shall be used for the City of Rockville in determining the applicable requirements from Chapter 4. Section R401.2 of the IECC is amended to read as follows: R401.2 Application. Residential buildings shall comply with Section R401.2.5 and either Section R401.2.1 or R401.2.3. Section R401.2.2 of the IECC is amended to read as follows: R401.2.2 Reserved. Section R401.2.4 of the IECC is amended to read as follows: R401.2.2 Reserved. Section R401.2.5 of the IECC is amended to read as follows: R401.2.5 Additional energy efficiency. This section establishes additional requirements applicable to all compliance approaches to achieve additional energy efficiency. 1. For all-electric buildings complying with Section R401.2.1, one of the additional efficiency package options shall be installed according to Section R408.2. 2. For mixed-fuel buildings complying with Section R401.2.1, the building shall be required to install either R408.2.1 or R408.2.5 of the additional efficiency package options, and any two of R408.2.2, R408.2.3, or R408.2.4 of the additional efficiency package options. 3. For buildings complying with the Energy Rating Index alternative Section R401.2.3, the Energy Rating Index value shall be at least 5 percent less than the Energy Rating Index target specified in Table R406.5. The options selected for compliance shall be identified in the certificate required by Section R401.3. Section R401.3 of the IECC is amended to read as follows: R401.3 Certificate. A permanent certificate shall be completed by the builder or other approved party and posted on a wall in the space where the furnace is located, a utility room or an approved location inside the building. Where located on an electrical panel, the certificate shall not cover or obstruct the visibility of the circuit directory label, service disconnect label or other required labels. The certification shall indicate the following: 1. The types, sizes, fuel sources, and efficiencies of heating, cooling and service water heating equipment. Where a gas-fired unvented room heater, electric furnace or baseboard electric heater is installed in the residence, the certificate shall indicate "gas-fired unvented room heater," "electric furnace" or "baseboard electric heater," as appropriate. An efficiency shall not be indicated for gas-fired unvented room heaters, electric furnaces and electric baseboard heaters. 2. The fuel sources for cooking and clothes drying equipment. 3. Where combustion equipment is installed, the certificate shall indicate information on the installation of additional electric infrastructure including which equipment and/or appliances include additional electric infrastructure, capacity reserved on the electrical service panel for replacement of each piece of combustion equipment and/or appliance 4. Where a solar-ready zone is provided, the certificate shall indicate the location, dimensions, and capacity reserved on the electrical service panel. Section R402.1 of the IECC is amended to read as follows: R402.1 General. The building thermal envelope shall comply with the requirements of Sections R402.1.1 through R402.1.2. Exceptions: 1. The following low-energy buildings, or portions thereof, separated from the remainder of the building by building thermal envelope assemblies complying with this section shall be exempt from the building thermal envelope provisions of Section R402. 1.1 Those containing no combustion equipment with a peak design rate of energy usage less than 3.4 Btu/hft2 (10.7 W/m2) or 1.0 watt/ft2 of floor area for space conditioning purposes. 1.2 Those containing no combustion equipment that do not contain conditioned space. Section R402.6 of the IECC is added to read as follows: R402.6 Moisture control. (Mandatory). The building design shall not create conditions of accelerated deterioration from moisture condensation. Above-grade frame walls, floors and ceilings not ventilated to allow moisture to escape shall be provided with an approved vapor retarder. The vapor retarder shall be installed on the warm-in-winter side of the thermal insulation. Exceptions: 1. In construction where moisture or its freezing will not damage the materials. 2. Frame walls, floors and ceilings in jurisdictions in Zone 4. (Crawl space floor vapor retarders are not exempted.) 3. Where other approved means to avoid condensation are provided. Section R403.1.1 of the IECC is amended to read as follows: R403.1.1 Thermostat. The thermostat controlling the primary heating or cooling system of the dwelling unit shall be California Title 24 compliant and capable of controlling the heating and cooling system on a daily schedule to maintain different temperature setpoints at different times of the day. This thermostat shall include the capability to set back or temporarily operate the system to maintain zone temperatures of not less than 55°F (13°C) to not greater than 85°F (29°C). The thermostat shall be programmed initially by the manufacturer with a heating temperature setpoint of not greater than 70°F (21°C) and a cooling temperature setpoint of not less than 78°F (26°C). The thermostat shall be provided with a demand responsive control capable of increasing the cooling setpoint by no less than 4°F (2.2°C) and decreasing the heating setpoint by no less than 4°F (2.2°C) in response to a demand response request. Section R403.5.4 is added to the IECC to read as follows: R403.5.4 Demand responsive water heating. All electric storage water heaters with a storage tank capacity greater than 20 gallons (76 L) shall be provided with demand responsive controls that comply with ANSI/CTA-2045-B or another approved demand responsive control. Section R404.4 and its subsections are added to the IECC to read as follows: R404.4 Renewable energy infrastructure. The building shall comply with the requirements of R404.4.1 or R404.4.2 R404.4.1 One- and two- family dwellings and townhouses. One- and two-family dwellings and townhouses shall comply with Sections R404.4.1.1 through R404.4.1.4. Exceptions: 1. A building with a permanently installed on-site renewable energy system. 2. A building with less than 600 square feet (55 m2) of roof area oriented between 110 degrees and 270 degrees of true north. 3. A building where all areas of the roof that would otherwise meet the requirements for a solar-ready zone are in full or partial shade for more than 70 percent of daylight hours annually. R404.4.1.1 Solar-ready zone area. The total area of the solar-ready zone shall not be less than 300 square feet (28 m2) and shall be composed of areas not less than 5.5 feet (1676 mm) in width and not less than 80 square feet (7.4 m2) exclusive of access or set back areas as required by the International Fire Code. Exception: Townhouses three stories or less in height above grade plane and with a total floor area less than or equal to 2,000 square feet (186 m2) per dwelling shall be permitted to have a solar-ready zone area of not less than 150 square feet (14 m2). R404.4.1.2 Obstructions. Solar-ready zones shall be free from obstructions, including but not limited to vents, chimneys, and roof-mounted equipment. R404.4.1.3 Electrical service reserved space. The main electrical service panel shall have a reserved space to allow installation of a dual pole circuit breaker for future solar electric installation and shall be labeled "For Future Solar Electric." The reserved space shall be positioned at the opposite (load) end from the input feeder location or main circuit location. R404.4.1.4 Electrical interconnection. An electrical junction box shall be installed within 24 inches (610 mm) of the main electrical service panel and shall be connected to a capped roof penetration sleeve or a location in the attic that is within 3 feet (914 mm) of the solar ready zone by one of the following: Section R404.4.2 is added to the IECC to read as follows: R404.4.2 Group R occupancies. Buildings in Group R-2, R-3 and R-4 shall comply with Section C405.13. Section R404.5 is added to the IECC to read as follows: R404.5 Electric vehicle charging infrastructure. Electric infrastructure for the current and future charging of electric vehicles shall be installed in accordance with this section. Section R404.5.1 is added to the IECC to read as follows: R404.5.1 One- and two- family dwellings and townhouses. One- and two-family dwellings and townhouses with a dedicated attached or detached garage or carport or on-site parking spaces and new detached garages shall be provided with one EVSE-installed parking space capable of providing at least Level 2 charging or one EV-ready parking space per dwelling unit. The branch circuit shall meet the following requirements: 1. A minimum capacity of 9.6 kVA 2. Terminates at a junction box or receptacle located within 3 feet (914 mm) of the parking space and labelled "For electric vehicle charging", and 3. The electrical panel directory shall designate the branch circuit as "For electric vehicle charging". Section R404.5.2 is added to the IECC to read as follows: R404.5.2 Group R occupancies. Parking facilities serving Group R-2, R-3 and R-4 occupancies shall comply with Section C405.14. Section R404.6 and its subsections are added to the IECC to read as follows: R404.6 Energy storage infrastructure. Each building site shall have a dedicated location for the installation of future on-site energy storage in accordance with this section. Exception: Where an onsite electrical energy system storage system is installed. R404.6.1 One- and two- family dwellings and townhouses. One- and two-family dwellings and townhouses shall be provided with an energy storage ready area in accordance with the following: 1. Floor area not less than 2 feet (610 mm) in one dimension and 4 feet (1219 mm) in another dimension and located in accordance with NFPA 1 and NFPA 70. 2. The main electrical service panel shall have a reserved space to allow installation of a two-pole circuit breaker for future electrical energy storage system installation. This space shall be labeled "For Future Electric Storage." The reserved spaces shall be positioned at the end of the panel that is opposite from the panel supply conductor connection. R404.6.2 Group R occupancies. Buildings with Group R-2, R-3 and R-4 occupancies shall comply with Section C405.15. Section R404.7 and its subsections are added to the IECC to read as follows: R404.7 Additional electric infrastructure. Combustion equipment shall be installed in accordance with this section. R404.7.1 Equipment serving multiple units. Combustion equipment that serves multiple dwelling units shall comply with Section C405.13. R404.7.2 Combustion water heating. Water heaters shall be installed in accordance with the following: 1. A dedicated 240-volt branch circuit with a minimum capacity of 30 amps shall terminate within 3 feet (914 mm) from the water heater and be accessible to the water heater with no obstructions. Both ends of the branch circuit shall be labeled with the words "For Future Heat Pump Water Heater" and be electrically isolated. 2. A condensate drain that is no more than 2 inches (51 mm) higher than the base of the installed water heater and allows natural draining without pump assistance shall be installed within 3 feet (914 mm) of the water heater. 3. The water heater shall be installed in a space with minimum dimensions of 3 feet (914 mm) by 3 feet (914 mm) by 7 feet (2134 mm) high. 4. The water heater shall be installed in a space with a minimum volume of 700 cubic feet (20,000 L) or the equivalent of one 16-inch (406 mm) by 24-inch (610 mm) grill to a heated space and one 8-inch (203 mm) duct of no more than 10 feet (3048 mm) in length for cool exhaust air. R404.7.3 Combustion space heating. Where a building has combustion equipment for space heating, the building shall be provided with a designated exterior location(s) in accordance with the following: 1. Natural drainage for condensate from cooling equipment operation or a condensate drain located within 3 feet (914 mm), and 2. A dedicated branch circuit in compliance with IRC Section E3702.11 based on heat pump space heating equipment sized in accordance with R403.7 and terminating within 3 feet (914 mm) of the location with no obstructions. Both ends of the branch circuit shall be labeled "For Future Heat Pump Space Heater." Exception: Where an electrical circuit in compliance with IRC Section E3702.11 exists for space cooling equipment. R404.7.4 Combustion clothes drying. A dedicated 240-volt branch circuit with a minimum capacity of 30 amps shall terminate within 6 feet (1829 mm) of natural gas clothes dryers and shall be accessible with no obstructions. Both ends of the branch circuit shall be labeled with the words "For Future Electric Clothes Drying" and be electrically isolated. R404.7.5 Combustion cooking. A dedicated 240-Volt, 40A branch circuit shall terminate within 6 feet (1829 mm) of natural gas ranges, cooktops and ovens and be accessible with no obstructions. Both ends of the branch circuit shall be labeled with the words "For Future Electric Range" and be electrically isolated. Section R405 of the IECC is deleted in its entirety. Table R406.2 of the IECC is amended as follows: Table R406.2 Requirements for Energy Rating Index SECTION | TITLE General R401.2.5 | Additional efficiency packages R401.3 | Certificate Building Thermal Envelope R402.1.1 | Vapor retarder R402.2.3 | Eave baffle R402.2.4.1 | Access hatches and doors R402.2.10.1 | Crawl space wall insultation installation R402.4.1.1 | Installation R402.4.1.2 | Testing Mechanical R403.1 | Controls R402.2.3 | Ducts R402.2.4.1 | Mechanical system piping insulation R403.5 except Section R403.5.2 | Service water heating R403.6 | Mechanical ventilation R403.7 | Equipment Sizing and efficiency rating R403.8 | Systems serving multiple dwelling units R403.9 | Snow melt and ice systems R403.10 | Energy consumption of pools and spas R403.11 | Portable spas R403.12 | Residential pools and permanent residential spas Electrical Power and Lighting Systems R404.1 | Lighting equipment R404.2 | Interior lighting controls R404.4 | Renewable energy infrastructure R404.5 | Electric vehicle charging infrastructure R404.6 | Energy storage infrastructure R404.7 | Additional electric infrastructure R406.3 | Building thermal envelope Section R406.5 of the IECC is amended to read as follows: R406.5 ERI-based compliance. Compliance based on an ERI analysis requires that the rated proposed design and confirmed built dwelling be shown to have an ERI less than or equal to 47 for proposed mixed-fuel buildings or 54 for proposed all-electric buildings, when compared to the ERI reference design. Section R407 of the IECC is deleted in its entirety. Section 408.2.3 of the IECC is amended to read as follows: R408.2.3 Reduced energy use in service water-heating option. The hot water system shall meet one of the following efficiencies: 1. Greater than or equal to 82 EF fossil fuel service water-heating system. 2. Greater than or equal to 2.0 EF electric service water-heating system. 3. Greater than or equal to 0.4 solar fraction solar water-heating system. 4. Greater than or equal to 82 EF instantaneous fossil fuel service water-heating system and drain water heat recovery unit meeting the requirements of Section R403.5.3 installed on at least one shower. Chapter 6 of the IECC is amended to add the following: CTA | Consumer Technology Association 1919 S. Eads Street Arlington, VA 22202 Standard reference number | Title | Referenced in code section number ANSI/CTA-2045-B | Modular Communications Interface for Energy Management ....... | .... R403.5.4
(Ord. No. 11-15, § 8, 6-1-15; Ord. No. 22-19, § 8, 9-9-19; Ord. No. 6-24, § I, 5-20-24)
Ask a question about Rockville law
Corpus searches the Rockville sections it holds and shows the ones that match, with their citations. Free, no sign-in.
