For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5-322 — Same—Amendments

City Code of the City of Rockville, Maryland (Codified through Ordinance No. 1-26, adopted January 12, 2026. (Supp. No. 17, Update 1)) · Rockville City Code § 5-322

Corpus is an independent public-information project, not the official City of Rockville website. Stable reference: corpuslaw.us/code/36210c3f-e313-4d54-bc4a-3876f05ba8a6

Sec. 5-322. - Same—Amendments.

The ICC International Green Construction Code, 2015 Edition (IgCC), is amended in the following respects: Section 101.1 of the IgCC is amended to read as follows: 101.1 Title. These regulations shall be known as the Green Construction Code of the City of Rockville, hereinafter referred to as "this code". Section 101.3 of the IgCC is amended to read as follows: 101.3 Scope. The provisions of this code shall apply to new construction as it relates to the design and construction of buildings and additions, building sites, removal and demolition of every building or structure or any appurtenances connected or attached to such buildings or structures and to the site on which the building is located. Occupancy classifications shall be determined in accordance with the International Building Code® (IBC ® ). Exceptions: 1. The code shall not apply to items 1.1, 1.2 and 1.3 except where the jurisdiction adopts the jurisdictional requirements of Section 302.1, Item 1, for residential buildings. 1.1. Detached one- and two-family dwellings and multiple single-family dwellings (townhouses) not more than three stories in height above grade plane with a separate means of egress, their accessory structures, and the site or lot upon which these buildings are located. 1.2. Group R-3 residential buildings, their accessory structures, and the site or lot upon which these buildings are located. 1.3. Group R-2 and R-4 residential buildings four stories or less in height above grade plane, their accessory structures, and the site or lot upon which these buildings are located. 2. The code shall not apply to equipment or systems that are used primarily for industrial or manufacturing. 3. The code shall not apply to temporary structures approved under Section 3103 of the International Building Code. 4. Where ASHRAE 189.1 is selected in accordance with Section 301.1.1, ASHRAE 189.1 shall not apply to buildings identified in Exceptions 1 through 3. 5. Where a minimum of USGBC-LEED Certification at the Silver level is selected as an alternative compliance path. 101.3.1 Residential construction. In lieu of the requirements of this code the following shall be deemed-to-comply with this code: 1. Group R-2 and R-4 residential buildings five stories or more in height above grade plane, their accessory structures, and the site or lot upon which these buildings are located achieve a minimum Silver performance level in Chapters 5 through 10 of the ICC 700- 2015 (National Green Building Standard) or equivalent system. 2. Group R-2 and R-4 portions of mixed use buildings must achieve a minimum Silver performance level in Chapters 5 through 10 of the ICC 700- 2015 (National Green Building Standard) or equivalent system. The remainder of the building and the site upon which the building is located shall comply with the provisions of this code. Section 101.4 of the IgCC is amended to read as follows: 101.4 Appendices. All the provisions in the Appendices, as amended, are adopted as part of the International Green Construction Code. Section 102.4 of the IgCC is amended to read as follows: 102.4 Referenced codes and standards. The following codes shall be considered part of the requirements of this code: the International Building Code, the International Energy Conservation Code® (IECC®), the International Existing Building Code® (IEBC®), Rockville Fire Code, the International Fuel Gas Code® (IFGC®), the International Mechanical Code® (IMC®), the International Plumbing Code® (IPC®), and the International Residential Code® (IRC®). Section 102.6 of the IgCC is amended to read as follows: 102.6 Existing structures. The legal occupancy of any structure existing on the date of adoption of this code shall be permitted to continue without change, except as is specifically covered in this code, the International Building Code, the International Existing Building Code, or the Rockville Fire Code, or as is deemed necessary by the Building Official for the general safety and welfare of building occupants and the public. Section 106.1 of the IgCC is amended to read as follows: 106.1 Required. Any owner or authorized agent who intends to construct, enlarge, alter, repair, move, demolish, or change the occupancy of a building or structure, or to erect, install, enlarge, alter, repair, remove, convert or replace any energy, electrical, gas, mechanical or plumbing system, the installation of which is regulated by this code, or to cause any such work to be done, shall first make application to the Building Official and obtain the required permit under the applicable code or regulation relevant to the intended work. A Green Building application will be filed with the Inspection Services Division; however, a separate permit shall not be issued under this code. Exemptions from permit requirements shall not be deemed to grant authorization for any work to be done in any manner in violation of the provisions of this code or any other applicable laws, codes or ordinances of this jurisdiction. Section 107(Fees) of the IgCC is deleted Section 108 of the IgCC is amended to read as follows: 108 Board of Adjustments and Appeals. Appeals of administrative interpretations or decisions made by the Building Official shall be administered in accordance with Chapter 5, Article I, Section 5-12 of the Rockville City Code. Section 301.1.1 of the IgCC is amended to read as follows: 301.1.1 Application. The requirements contained in this code are applicable to buildings, or portions of buildings. As indicated in Section 101.3, these buildings shall meet either the requirements of ASHRAE 189.1 or the requirements contained in this code or demonstrate compliance using an equivalent option that must be first approved by the Building Official and where the applicant demonstrates equivalency and compliance. Section 302.1 of the IgCC is amended to read as follows: 302.1 Requirements and electives determined by the jurisdiction. The jurisdiction shall indicate the following information in Table 302.1 for inclusion in its code adopting ordinance: 1. The jurisdiction shall indicate whether requirements for residential buildings, as indicated in Exception 1 to Section 101.3, are applicable by selecting "Yes" or "No" in Table 302.1. Where "Yes" is selected, the provisions of ICC 700 shall apply and the remainder of this code shall not apply. 2. Requirements: Where "Yes" or "No" boxes are provided, the box checked "Yes" indicates where that section or subsection, as amended, is to be enforced as a mandatory requirement in the jurisdiction, or "No" indicates where that section or subsection is not to be enforced as a mandatory requirement in the jurisdiction. 3. Electives: Where "Yes" boxes are provided, the box checked "Yes" indicates where that section or subsection, as amended, is not required and is relocated to Appendix A- Project Electives, Section A110 Additional Project Electives and is eligible for selection as a project elective in the jurisdiction. Table 302.1 of the IgCC is amended to read as follows: Section | Section Title or Description and Directives | Jurisdictional Requirements | Jurisdictional Electives (Appendix A) CHAPTER 1. SCOPE 101.3 Exception 1.1 | Detached one- and two-family dwellings and multiple single-family dwellings (townhouses) not more than three stories in height above grade plane with a separate means of egress, their accessory structures, and the site or lot upon which these buildings are located, shall comply with ICC 700. | ☑ Yes | □ No 101.3 Exception 1.2 | Group R-3 residential buildings, their accessory structures, and the site or lot upon which these buildings are located, shall comply with ICC 700. | ☑ Yes | □ No 101.3 Exception 1.3 | Group R-2 and R-4 residential buildings four stories or less in height above grade plane, their accessory structures, and the site or lot upon which these buildings are located, shall comply with ICC 700. | ☑ Yes | □ No CHAPTER 4. SITE DEVELOPMENT AND LAND USE 401.2 | Predesign site inventory and assessment | □ Yes | ☑ No 402 | Preservation of Natural Resources | □ Yes | ☑ No 403 | Stormwater Management | □ Yes | ☑ No 404 | Landscape Irrigation and Outdoor Fountains | □ Yes | ☑ No | ☑ Yes 405.1-405.2 | Management of Vegetation, Soils and Erosion Control | □ Yes | ☑ No 405.3 | Native plant landscaping | □ Yes | ☑ No | ☑ Yes 406 | Building Site Waste Management | ☑ Yes | □ No 407.1-407.3 | Transportation Impact | □ Yes | ☑ No 407.4 | Preferred vehicle parking | □ Yes | ☑ No | ☑ Yes 408 | Heat Island Mitigation | ☑ Yes | □ No 409 | Site Lighting | □ Yes | ☑ No | ☑ Yes CHAPTER 5. MATERIAL RESOURCE CONSERVATION AND EFFICIENCY 502 | Construction Material Management | ☑ Yes | □ No 503 | Construction Waste Management | ☑ Yes | □ No 503.1 | Minimum percentage of waste material diverted from landfills | ☑ Yes (50%) 504 | Waste Management and Recycling | ☑ Yes | □ No 505 | Material Selection | □ Yes | ☑ No | ☑ Yes 506 | Lamps | □ Yes | ☑ No | ☑ Yes CHAPTER 6. ENERGY CONSERVATION, EFFICIENCY AND CO2 e EMISSION REDUCTION 302.1, 302.1.1, 602.1 | Zero Energy Performance Index (zEPI) of Jurisdictional Choice - The jurisdiction shall indicate a zEPI of 50 or less in each occupancy for which it intends to require enhanced energy performance. | ☑ Yes Occupancy; ALL zEPI: 50 | □ No 603 | Energy Metering, Monitoring and Reporting | ☑ Yes | □ No 604 | Automated Demand-Response (Auto-DR) Infrastructure | □ Yes | ☑ No | ☑ Yes 605 | Building Envelope Systems | ☑ Yes | □ No 606 | Building Mechanical Systems (as amended) | ☑ Yes | □ No 606.5.1 | Economizer Systems | □ Yes | ☑ No | ☑ Yes 607 | Building Service Water Heating Systems (as amended) | ☑ Yes | □ No 608 | Building Electrical Power and Lighting Systems | □ Yes | ☑ No | ☑ Yes 609 | Specific Appliances and Equipment | □ Yes | ☑ No | ☑ Yes 610 | Onsite Renewable Energy Systems | □ Yes | ☑ No | ☑ Yes 611 | Energy Systems Commissioning and Completion | ☑ Yes | □ No 612 | Outcome-Based Pathway Requirements | □ Yes | ☑ No CHAPTER 7. WATER RESOURCE CONSERVATION, QUALITY AND EFFICIENCY 701.2 | Water usage metering required | □ Yes | ☑ No 702.1-702.4 | Fitting and fixture consumption through Drinking fountain controls | ☑ Yes | □ No 702.5 | Appliances | □ Yes | ☑ No | ☑ Yes 702.6-702.19 | Municipal Reclaimed Water through Film Processors | □ Yes | ☑ No 703 | HVAC Systems and Equipment (as amended) | ☑ Yes | □ No 704 | Water Treatment Devices and Equipment | □ Yes | ☑ No CHAPTER 8. INDOOR ENVIRONMENTAL QUALITY AND COMFORT 802 | Building Construction Features, Operations and Maintenance Facilitation | ☑ Yes | □ No 803 | HVAC Systems | ☑ Yes | □ No 804 | Specific Indoor Air Quality and Pollutant Control Measures | □ Yes | ☑ No 804.2 | Post-Construction Pre-Occupancy Baseline IAQ Testing | □ Yes | ☑ No | ☑ Yes 805 | Prohibited Materials | ☑ Yes | □ No 806 | Material Emissions and Pollutant Control | □ Yes | ☑ No | ☑ Yes 807 | Acoustics | □ Yes | ☑ No | ☑ Yes 808 | Daylighting | □ Yes | ☑ No | ☑ Yes CHAPTER 9. COMMISSIONING, OPERATION AND MAINTENANCE 902 | Special Inspection and Commissioning | ☑ Yes | □ No 903 | Building Operations and Maintenance Documentation | ☑ Yes | □ No 904 | Building Operations and Maintenance | ☑ Yes | □ No CHAPTER 10. EXISTING BUILDINGS Chapter 10 | Existing Buildings | □ Yes | ☑ No CHAPTER 11. EXISTING BUILDING SITE DEVELOPMENT Chapter 11 | Existing Building Site Development | □ Yes | ☑ No APPENDIX A: PROJECT ELECTIVES A103 | Minimum 10 project electives shall be selected from sections A104 through A110, as amended. | ☑ Yes | □ No Section 302.1.1 of the IgCC is amended to read as follows: 302.1.1 zEPI of 50 or less. Where a zEPI of 50 or less is indicated by the jurisdiction in Table 302.1, buildings shall comply on a performance-basis in accordance with Section 601.3.1. Exception: Buildings less than 25,000 square feet (2323 m2) in total building floor area pursuing compliance on a prescriptive basis shall be deemed to have a zEPI of 50 and shall not be required to comply with the zEPI of Jurisdictional Choice indicated by the jurisdiction in Table 302.1. Sections 401.2 (Predesign site inventory and Assessment) of the IgCC is deleted in its entirety. Section 402 (Preservation of Natural Resources) of the IgCC is deleted in its entirety. Section 403 (Stormwater Management) of the IgCC is deleted in its entirety. Section 404 (Landscape Irrigation and Outdoor Fountains) is removed and added to Appendix A Section A110-404 of this Code. Section 405.1 (Soil and water quality protection) and Section 405.2 (Vegetation and soil protection)of the IgCC are deleted in its entirety. Section 405.3 (Native Plant Landscaping) is removed and added to Appendix A Section A110-405.3 of this Code. Section 407.1 (Walkways and bicycle paths) throughSection 407.3.2 (Long-term bicycle parking) of the IgCC are deleted in their entirety. Section 407.4 (Preferred vehicle parking) is removed and added to Appendix A Section A110- 407.4 of this Code. Section 408.2 (Site hardscape) is amended to read as follows: Section 408.2 Site hardscape. In climate zones 1 through 6, as established in the International Energy Conservation Code, not less than 40 percent of the site hardscape shall be provided with one or any combination of options described in Sections 408.2.1 through 408.2.4. For the purposes of this section, site hardscape shall not include areas of the site covered by solar photovoltaic arrays or solar thermal collectors. Section 409 (Site Lighting) is removed and added to Appendix A Section A110-409 of this Code. Section 503.2 is added to the IgCC to read as follows: Section 503.2 Deconstruction and demolition material and waste management plan. Where buildings, structures or portions thereof are deconstructed or demolished, a minimum of 50 percent of materials shall be diverted from landfills. A construction material and waste management plan shall be developed that is in accordance with Section 503.1, that includes procedures for deconstruction, procedures for the proper removal, management and disposal of hazardous materials (including, but not limited to materials and devices containing mercury, poly-chlorinated biphenyl, lead, asbestos, CFCs, and HCFCs), and documentation on the total materials in buildings, structures and portions thereof to be deconstructed or demolished and the materials to be diverted. Sections 505 (Material Selection) and 506 (Lamps) are removed and added to Appendix A Section A110-505 and Section A110-506 of this Code. Section 604 (Automated Demand-Response Infrastructure) is removed and added to Appendix A Section A110 of this Code. Section 606.5.1 (Economizer systems) is removed and added to Appendix A Section A110-606.5.1 of this Code. Section 608 (Building Electrical Power and Lighting Systems) of the IgCC is deleted in its entirety. Section 609 (Specific Appliances and Equipment) is removed and added to Appendix A Section A110-609 of this Code. Section 610 (Onsite Renewable Energy Systems) is removed and added to Appendix A Section A110-610 of this Code. Section 612 (Outcome-Based Pathway Requirements) of the IgCC is deleted in its entirety. Section 701.2 (Water usage metering required) is removed and added to Appendix A Section A110-701.2 of this Code. Section 702.5 (Appliances) is removed and added to Appendix A Section A110-702.5 of this Code. Sections 702.6 (Municipal reclaimed water) through 702.19 (Film processors) of the IgCC are deleted in their entirety. Sections 703.1 (Hydronic closed system), 703.2 (Humidification systems), 703.3 (Condensate coolers and tempering), 703.4 (Condensate drainage recovery), 703.6 (Humidifier discharge), 703.7 (Cooling towers, evaporative condensers and fluid coolers), 703.8 (Wet-hood exhaust scrubber systems), of the IgCC are deleted in their entirety. Section 704 (Water Treatment Devices and Equipment) is removed and added to Appendix A Section A110-704 of this Code. Section 803.3.1(1) of the IgCC is amended to read as follows: 803.3.1(1) The enclosing walls shall extend from the floor surface to the underside of the floor, roof deck or solid ceiling above and shall be constructed to resist the passage of airborne chemical pollutants and shall be constructed and sealed as required for a smoke partition in a fully sprinklered building or 1-hour fire-resistance-rated construction assemblies. Alternatively, for janitorial rooms and closets, all chemicals shall be stored in approved chemical safety storage cabinets. Section 804.1 (Fireplaces and appliances)of the IgCC is deleted in its entirety. Section 804.2 (Post-construction, pre-occupancy baseline IAQ testing) is removed and added to Appendix A Section A110-804.2 of this Code. Sections 806 (Material Emissions and Pollutant Control), 807 (Acoustics), and 808 (Daylighting) are removed and added to Appendix A Section A110-806, Section A110-807, Section A110-808 of this Code, accordingly. Section 902.1.1.1 of the IgCC is amended to read as follows: 902.1.1.1 Qualifications of approved agencies. An approved agency shall be qualified and shall demonstrate competence, to the satisfaction of the Building Official, for the commissioning of the particular type of construction or operation. The registered design professional in responsible charge and engineers of record involved in the design of the project are permitted to act as the approved agency provided those personnel meet the qualification requirements of this section to the satisfaction of the Building Official. The approved agency shall provide written documentation to the Building Official demonstrating competence and relevant experience or training. Experience or training shall be considered relevant where the documented experience or training is related in complexity to the same type of commissioning activities for projects of similar complexity and material qualities. Chapter 10 (Existing Buildings) of the IgCC is deleted in its entirety. Chapter 11 (Existing Building Site Development)of the IgCC is deleted in its entirety. Section A103.2 of the IgCC is amended to read as follows: A103.2 Required number of and selection of project electives. A total of not less than 10 project electives shall be selected by the owner or the owner's authorized agent from Table A103.2. Selected project electives shall be applied as mandatory requirements for the project. Selected project electives shall be communicated to the Building Official by means of checking the appropriate boxes in the tables and providing a copy of the tables, or by inclusion of a list of selected project electives, with the construction documents. Table A103.2 Project Electives of the IgCC is amended to read as follows: Section | Description | Owner Selection A104.2 | Wildlife corridor | □ Yes | □ No A104.3 | Infill site | □ Yes | □ No A104.4 | Brownfield site | □ Yes | □ No A104.5 | Site restoration | □ Yes | □ No A104.6 | Mixed-use development | □ Yes | □ No A104.9.1 | Site hardscape project elective 1 | □ Yes | □ No A104.9.2 | Site hardscape project elective 2 | □ Yes | □ No A104.9.3 | Site hardscape project elective 3 | □ Yes | □ No A104.9.4 | Roof covering project elective | □ Yes | □ No A105.1 | Waste management | □ Yes | □ No A105.2 | Construction waste landfill maximum | □ Yes | □ No A105.3(1) | Reused, recycled content, recyclable, bio-based and indigenous materials (70%) | □ Yes | □ No A105.3(2) | Reused, recycled content, recyclable, bio-based and indigenous materials (85%) | □ Yes | □ No A105.4 | Service life plan | □ Yes | □ No A105.5 | Design for construction and building reuse | □ Yes | □ No A105.6 | Existing building reuse | □ Yes | □ No A105.7 | Historic building reuse | □ Yes | □ No A105.8 | Integrated design | □ Yes | □ No A105.9 | Deconstruction | □ Yes | □ No A106.1 | zEPI is at least 5 points lower than required by Table 302.1 | □ Yes | □ No zEPI is at least 10 points lower than required by Table 302.1 | □ Yes | □ No zEPI is at least 15 points lower than required by Table 302.1 | □ Yes | □ No zEPI is at least 20 points lower than required by Table 302.1 | □ Yes | □ No zEPI is at least 25 points lower than required by Table 302.1 | □ Yes | □ No zEPI is at least 30 points lower than required by Table 302.1 | □ Yes | □ No zEPI is at least 35 points lower than required by Table 302.1 | □ Yes | □ No zEPI is at least 40 points lower than required by Table 302.1 | □ Yes | □ No zEPI is at least 45 points lower than required by Table 302.1 | □ Yes | □ No zEPI is at least 50 points lower than required by Table 302.1 | □ Yes | □ No A106.2 | Mechanical system project elective | □ Yes | □ No A106.3 | Service water heating | □ Yes | □ No A106.4 | Lighting Systems | □ Yes | □ No A106.5 | Passive design | □ Yes | □ No A106.6 | Renewable energy systems- 5 percent | □ Yes | □ No A106.6 | Renewable energy systems- 10 percent | □ Yes | □ No A106.6 | Renewable energy systems- 20 percent | □ Yes | □ No A107.2 | Onsite wastewater treatment | □ Yes | □ No A107.3 | Alternative onsite potable water for outdoor host connections | □ Yes | □ No A107.4 | Alternative onsite potable water for plumbing fixture flushing | □ Yes | □ No A107.5 | Automatic fire sprinkler system | □ Yes | □ No A107.6 | Alternative onsite nonpotable water to fire pumps | □ Yes | □ No A107.7 | Alternative onsite nonpotable water for industrial process makeup water | □ Yes | □ No A107.8 | Alternative onsite nonpotable water for cooling tower makeup water | □ Yes | □ No A107.9 | Gray water collection | □ Yes | □ No A108.2 | VOC emissions - flooring | □ Yes | □ No A108.3 | VOC emissions - ceiling systems | □ Yes | □ No A108.4 | VOC emissions - wall systems | □ Yes | □ No A108.5 | Architectural paints and coatings | □ Yes | □ No A108.6 | Total VOC limit | □ Yes | □ No A108.7 | Views to building exterior | □ Yes | □ No A110-404 | Landscape Irrigation and Outdoor Fountains | □ Yes | □ No A110-405.3 | Native Plant Landscaping | □ Yes | □ No A110-407.4 | Preferred Vehicle Parking | □ Yes | □ No A110-409 | Site Lighting | □ Yes | □ No A110-505 | Material Selection | □ Yes | □ No A110-506 | Lamps | □ Yes | □ No A110-604 | Automated Demand-Response (Auto-DR) Infrastructure | □ Yes | □ No A110-606.5.1 | Economizer Systems | □ Yes | □ No A110-608.2 - 608.9 | Building Electrical Power and Lighting Systems | □ Yes | □ No A110-609.2.3 | Specific Appliances and Equipment | □ Yes | □ No A110-610 | Onsite Renewable Energy Systems | □ Yes | □ No A110-701.2 | Water Usage Metering | □ Yes | □ No A110-702.5 | Appliances | □ Yes | □ No A110-704 | Water Treatment Devices and Equipment | □ Yes | □ No A110-804.2 | Post-Construction Pre-Occupancy Baseline IAQ Testing | □ Yes | □ No A110-806 | Material Emissions and Pollutant Control | □ Yes | □ No A110-807 | Acoustics | □ Yes | □ No A110-808 | Daylighting | □ Yes | □ No Sections A104.1 (Flood hazard area project elective), A104.7 (Changing and shower facilities project elective) and 104.8 (Long-term bicycle parking and storage project elective) of the IgCC are deleted in their entirety. Section A110 of the IgCC is added to read as follows: Section A110 Additional Project Electives A110.1 Additional Project Electives. The following Sections and Subsections are removed from Chapter 3 through Chapter 8 of this code and relocated to Appendix A to be optional requirements:, 404, 405.3, 407.4, 409, 505, 506, 604, 606.5.1, 608.2-608.9, 609.2.3, 610, 701.2, 702.5, 704, 804.2, 806, 807 and 808. Section and subsection numbers, titles and provisions shall remain consistent, unless otherwise amended. Each section or subsection is considered as separate project electives. The electives shall be cumulative and compliance with each project elective shall be recognized individually.

(Ord. No. 11-15, § 14, 6-1-15; Ord. No. 22-19, § 14, 9-9-19; Ord. No. 6-24, § I, 5-20-24)

Ask a question about Rockville law

Corpus searches the Rockville sections it holds and shows the ones that match, with their citations. Free, no sign-in.