§ 9-120 — Adopted
City Code of the City of Rockville, Maryland (Codified through Ordinance No. 1-26, adopted January 12, 2026. (Supp. No. 17, Update 1)) · Rockville City Code § 9-120
Corpus is an independent public-information project, not the official City of Rockville website. Stable reference: corpuslaw.us/code/67367e92-22cb-4c8f-b210-261eca02f2ae
Sec. 9-120. - Adopted.
The NFPA 72, National Fire Alarm and Signaling Code, 2022 Edition, as issued by the National Fire Protection Association, is hereby adopted by reference, except as amended by Section 9-121 of this chapter. One (1) copy of such publication, as adopted, shall be maintained by the Inspection Services Division in the City Hall and made available for inspection by the public during regular office hours. Any amendment or change in such code promulgated by the NFPA shall not become part of this article until the modifications have been duly adopted by ordinance. Section 10.18.3 of NFPA 72, the National Fire Alarm and Signaling Code, 2022 Edition adds the following: 10.18.3 Annunciator Access and Location. An annunciator with the following features is required when the building is greater than one story, has a sprinkler system, or has more than one type of alarm initiating device. Exception 1: Apartments protected by a 13R sprinkler system Exception 2: Any building not exceeding two stories above grade and 3,000 square feet per floor. (a) Annunciator must have a visible signal for each different floor, zone and device type. Supervise computer screen or printer type annunciators may be used to meet this requirement if the zone identification is approved by the Fire Marshall. (b) Unless approved by the AHJ, zones must not exceed a single floor, 52,000 square feet, or 300 linear feet. Sprinkler systems are permitted to be zoned under the applicable sprinkler standard. (c) In zones greater than 22,500 square feet, a graphic outline on or adjacent to the annunciator must be provided showing the building outline, fire alarm and sprinkler zone boundaries, "you are here" notation, north compass arrow, all stairways, stairway identification numbers, sprinkler zones, all standpipe risers, fire department connections, elevators, and the building address. (d) A lamp type annunciator must have a lap test switch unless the annunciator circuits are supervised. (e) The annunciator must be located at, and visible from, the main fire department entrance unless the building has a fire command center. (f) If two or more buildings are controlled by one alarm system, an annunciator must be installed in each building with a pilot lamp indicating the building or alarm origination. (g) The graphic orientation must match the building orientation. (h) The graphic floor level designation must match the elevator floor level designations. Paragraph 10.21.5 of the NFPA 72, National Fire Alarm and Signaling Code, 2022 Edition, is amended to read as follows: 10.21.5 Where a required fire alarm system is impaired or out of service for more than four (4) hours in a twenty-four (24) hour period, mitigating measures shall be in accordance with Section 9-14 of the Rockville City Code. Paragraph 17.7.6.4.2.1 of the NFPA 72, National Fire Alarm and Signaling Code, 2022 Edition, is amended by adding subparagraph 17.7.6.4.2.1.1 to read as follows: 17.7.6.4.2.1.1 Duct detection, if provided, must sound a supervisory signal. Paragraph 17.7.6.4.2.2 of the NFPA 72, National Fire Alarm and Signaling Code, 2022 Edition, is amended by adding subparagraph 17.7.6.4.2.1.1 to read as follows: 17.7.6.4.2.2.1 Duct detection, if provided, must sound a supervisory signal. Paragraph 17.13.2 of the NFPA 72, National Fire Alarm and Signaling Code, 2022 Edition, is amended to by adding subparagraph 17.13.2.1 to read as follows: 17.13.2.1 Standpipe or main water flow indicators, if provided, must sound a supervisory signal. Section 18.3 of the NFPA 72, National Fire Alarm and Signaling Code, 2022 Edition, is amended by adding Sub-section 18.3.8 to read as follows: 18.3.8 Calculations. Calculations for amperage capacity of notification circuits shall provide for a minimum of a 20 percent safety factor on each circuit. Subsection 18.4.1 of the NFPA 72, National Fire Alarm and Signaling Code, 2022 Edition, is amended by adding Paragraph 18.4.1.8 to read as follows: 18.4.1.8 Where variable volume settings are provided with an audible device, the spacing shall be based on the low volume level. Paragraph 24.8.16 of the NFPA 72, National Fire Alarm and Signaling Code, 2022 Edition, is amended to read as follows: 24.8.16 If telephone jacks are provided, six (6) or more portable handsets (as determined by the authority having jurisdiction) shall be stored at each control center for use by emergency responders. Paragraph 29.11.3.4 of the NFPA 72 National Fire Alarm and Signaling Code, 2022 Edition, is amended by adding the following subsection: 29.11.3.4(14) Enclosed rooms with a closet such as dens, libraries, studies, or sitting rooms which could be used as a sleeping area must be treated as bedrooms.
(Ord. No. 8-16, 6-20-16; Ord. No. 3-21, 2-22-21; Ord. No. 17-25, § I, 12-15-25)
Ask a question about Rockville law
Corpus searches the Rockville sections it holds and shows the ones that match, with their citations. Free, no sign-in.
