§ 9-74 — Same—Amendments

City Code of the City of Rockville, Maryland (Codified through Ordinance No. 1-26, adopted January 12, 2026. (Supp. No. 17, Update 1)) · Rockville City Code § 9-74

Corpus is an independent public-information project, not the official City of Rockville website. Stable reference: corpuslaw.us/code/1cf36fff-96db-4d3d-af05-e810407711ba

Sec. 9-74. - Same—Amendments.

The NFPA 1, Fire Code, 2024 Edition, is amended in the following respects: Section 1.7.12.2 of the NFPA 1, Fire Code, 2024 Edition, is amended by adding the following sentence: The AHJ shall be authorized to require plans to bear the stamp of a registered design professional. Section 1.11 of the NFPA 1, Fire Code, 2024 Edition, is deleted. Section 1.12 of the NFPA 1, Fire Code, 2024 Edition, is deleted. Subsection 1.13.1 of the NFPA 1, Fire Code, 2024 Edition, is amended by adding Paragraph 1.13.1.1 to read as follows: 1.13.1.1 Permits, certificates, notices, approvals, or orders required by this code shall be governed by the policies and procedures of the AHJ. Subsection 1.13.6.13 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 1.13.6.13 Permits may be issued by the AHJ and shall indicate the following: (1) Operation, activities, or construction for which the permit is issued (2) Address or location where the operation, activity, or construction is to be conducted. (3) Name, address, and phone number of the permittee (4) Permit number (5) Period of validity of the permit (6) Inspection requirements (7) Name of the agency authorizing the permit (8) Date of issuance (9) Permit conditions as determined by the AHJ. Subsection 1.13.8 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 1.13.8 Where additional permits, approvals, certificates, or licenses are required by other agencies, approval may be obtained from those other agencies. Subsection 1.14.2 of the NFPA 1, Fire Code, 2024 Edition is amended to read as follows: 1.14.2 The AHJ may require certificates of fitness and collect fees for individuals or companies performing any of the following activities: (1) Use of explosive materials (2) Fireworks displays involving display fireworks Section 1.14.12.4 of the NFPA 1, Fire Code, 2024 Edition, is deleted. Section 1.17.4.3 of the NFPA 1, Fire Code, 2024 Edition, is deleted. Section 2.1.1 of the NFPA 1, Fire Code, 2024 Edition, is amended as follows: Where permitted by the AHJ, compliance with subsequent editions of reference publications shall be considered evidence of compliance with the editions specified in this Code Section 2.1.1.1 of the NFPA 1, Fire Code, 2024 Edition, is amended as follows: Where permitted by the AHJ, compliance with subsequent editions of reference publications shall be achieved by complying with the entire subsequent edition of the referenced publication. Section 2.1.1.2 of the NFPA 1, Fire Code, 2024 Edition, is amended as follows: Where permitted by the AHJ, compliance with individual specific sections contained subsequent edition referenced publications, and not the entire reference publication, shall only be approved by the AHJ through technical documentation submitted in compliance with 1.4.1 or 1.4.2. Section 2.2 of the NFPA 1, Fire Code, 2024 Edition, is amended as follows: Delete the referenced publication NFPA 5000, Building Construction and Safety Code, 2024 Edition. Add Rockville City Code, Chapter 5, Buildings and Building Regulations. Wherever NFPA 5000 is referenced, other than for extracted text, substitute Rockville City Code, Chapter 5, Buildings and Building Regulations. Delete the referenced publication NFPA 150 Standard on Fire and Life Safety in Animal Housing Facilities, 2022 Edition. Section 2.4 of the NFPA 1, Fire Code, 2024 Edition, is amended as follows: Delete the referenced publication NFPA 5000, Building Construction and Safety Code, 2024 Edition. Add Rockville City Code, Chapter 5, Buildings and Building Regulations. Wherever NFPA 5000 is referenced, other than for extracted text, substitute Rockville City Code, Chapter 5, Buildings and Building Regulations. Paragraph 3.3.17 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 3.3.17.12 Consumer Fireworks Retail Sales Area. The portion of a consumer fireworks retail sales facility or store, including the immediately adjacent aisles, where consumer fireworks are located for the purpose of retail display and sale to the public. Paragraph 3.3.136 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 3.3.136 Fireworks*. Any composition or device for the purpose of producing a visible or audible effect for entertainment purposes by combustion, deflagration or detonation, and that meets the definition of Consumer Fireworks or Display Fireworks as set forth in NFPA 1124, and as referenced in Public Safety Article, § 10-101, Annotated Code of Maryland. Paragraph 3.3.136.1 of the NFPA 1, Fire Code, 2024 Edition is amended to read as follows: 3.3.136.1* Display Fireworks. Large fireworks devices that are explosive materials intended for use in fireworks displays and designed to produce visible or audible effects by combustion, deflagration, or detonation, as set forth in CFR 555, 49 CFR 172, APA87-1, Standard for Construction and Approval for Transportation of Fireworks, Novelties, and Theatrical Pyrotechnics, and as referenced in Public Safety Article 10-101, Annotated Code of Maryland. Section 3.3.175 of the NFPA 1, Fire Code, 2024 Edition, is deleted. Paragraph 3.3.203.6 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 3.3.203.6* Day-Care Home. A building or portion of a building in which not more than twelve (12) clients receive care, maintenance, and supervision, by other than their relative(s) or legal guardian(s), for less than twenty-four (24) hours per day. Paragraph 3.3.203.7 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 3.3.203.7* Day-Care Occupancy. An occupancy in which clients receive care, maintenance, and supervision, by other than their relatives or legal guardians, for less than twenty-four (24) hours per day. Paragraph 3.3.203.25 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 3.3.203.25 One- and Two-Family Dwelling. One- and two-family dwellings include buildings containing not more than two (2) dwelling units in which each dwelling unit is occupied by members of a single family with not more than five (5) unrelated individuals. Paragraph 3.3.203.28 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 3.3.203.28* Residential Board and Care Facility. An occupancy used for lodging and boarding of six (6) or more residents, not related by blood or marriage to the owner or operators, for the purpose of providing personal care services. Paragraph 4.5.8.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 4.5.8.1 Whenever or wherever any device, equipment, system, condition, arrangement, level of protection, fire-resistive construction, or any other feature is required, such device, equipment, system, condition, arrangement, level of protection, fire-resistive construction, or other feature shall thereafter be continuously maintained in accordance with applicable NFPA requirements or requirements developed as part of a performance-based design, or as directed by the AHJ. Paragraph 4.5.8.3 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 4.5.8.3* Existing life safety features obvious to the public, tenants, or occupants, and where not required, shall be either maintained or removed. Paragraph 6.1.4.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 6.1.4.1* Definition - Day-Care Occupancy. An occupancy in which clients receive care, maintenance, and supervision, by other than their relatives or legal guardians, for less than twenty-four (24) hours per day. Paragraph 6.1.8.1.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 6.1.8.1.1* Definition - One- and Two-family Dwelling Unit. A building that contains not more than two dwelling units, each dwelling unit occupied by members of a single family with not more than five unrelated individuals. Paragraph 6.1.9.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 6.1.9.1* Definition - Residential Board and Care Facility. A building or portion thereof that is used for lodging and boarding of six (6) or more residents, not related by blood or marriage to the owner or operators, for the purpose of providing personal care services. Subsection 10.1.2 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 10.1.2* Life Safety Code. Every new and existing building shall comply with this Code and NFPA 101, Life Safety Code except as amended by Chapter 9, Fire Code, of the Rockville City Code. Paragraph 10.2.7.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 10.7.2.1 Fire prevention inspections shall occur on existing premises in accordance with the minimum inspection frequency schedule specified by the AHJ and Table 10.2.7.1. Annex A of the NFPA 1, Fire Code, 2024 Edition, is amended to add the following new paragraph: A.10.2.7.1 The frequency of fire prevention inspections of existing buildings should be based upon a risk assessment of these properties completed by the responsible AHJ. Considerations for this assessment should include, but not be limited to, the occupancy classification of the building and hazards associated with that classification; the number, location, and physical and mental capabilities of potential building occupants (especially self-evacuation abilities); construction design and maintenance of the property; fire protection features of the building; special hazards associated with activities or operations conducted within the building; available fire department suppression resources with special consideration to necessary special suppression operations; and resources available for fire code inspections and enforcement actions. Subsection 10.5.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 10.5.1 No person shall fail to leave a building when notified to do so when directed by the AHJ or incident commander as a result of a known or perceived emergency. Subsection 10.5.2 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 10.5.2 Persons shall not fail to leave any overcrowded premises when ordered to do so by the AHJ or Incident Commander. Paragraph 10.10.6.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 10.10.6.1 Unless permitted by 10.10.6.2, for other than one- and two-family dwellings, outdoor cooking appliances, grills, or other similar devices intended for cooking, heating, or any other purpose shall not be used, kindled, or stored in any of the following locations: (1) on any balcony; (2) under any overhanging portion of a structure; or (3) within 20 ft (6.1 m) of any structure. Paragraph 10.10.6.2 of the NFPA 1, Fire Code, 2024 Edition, is deleted. Section 10.10 of the NFPA 1, Fire Code, 2024 Edition, is amended by adding Subsection 10.10.11 to read as follows: 10.10.11 Fire Pits, Fire Bowls, Chimineas, and Similar Devices. 10.10.11.1 Use of fire pits, fire bowls, chimineas, and similar devices shall be subject to the requirements of Subsection 10.10.1 of this Code. 10.10.11.2 Use of these devices shall be in accordance with the manufacturer's guidelines. 10.10.11.3 No fire pit, fire bowl, chiminea, or similar device shall be used on any balcony or under any overhanging portion, or within 20 ft. (6.1 m) from any building or structure, and no less than 3 ft. (0.9 m) from combustible materials. 10.10.11.4 No burning of trash or construction materials shall be permitted. 10.10.11.5 A garden hose attached to a hose bib capable of supplying water shall be available. The hose shall be long enough to reach the device. 10.10.11.6 Ashes shall be dampened until cool and stored in a non-combustible container dedicated to ash storage. Paragraph 10.11.1.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 10.11.1.1 New and existing buildings shall have premises identification conforming to the requirements of Chapter 9, Article II of the Rockville City Code. Subsection 10.11.1 of the NFPA 1, Fire Code, 2024 Edition, is amended by adding Subparagraph and Paragraph as follows: 10.11.1.1.1 Subject to the approval of the AHJ, individual suites within structures and rear exterior entrances and/or access from service corridors shall be clearly identified. 10.11.1.9 Where required by the AHJ, symbols in compliance with NFPA 170 Standard for Fire Safety and Emergency Symbols shall be used. Paragraph 10.11.1.2 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 10.11.1.2 Premises identification shall be in accordance with Chapter 9, Article II of the Rockville City code. Paragraph 10.11.1.3 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 10.11.1.3 Premises identification shall contrast with their background. Paragraph 10.11.1.4 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 10.11.1.4 Premises identification shall be Arabic numerals or alphabet letters Paragraph 10.11.1.6 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 10.11.1.6 Where required by the AHJ, the assignment of addresses to buildings shall be in accordance with an approved method. Paragraph 10.11.1.7 of the NFPA 1, Fire Code, 2024 Edition, is deleted. Paragraph 10.11.1.8 of the NFPA 1, Fire Code, 2018 Edition, is amended to read as follows: 10.11.1.8 Premises Identification for suites within a multiple tenant building or complex shall be individually identified in a manner approved by the AHJ. Subsection 10.11.4 of the NFPA 1, Fire Code, 2024 Edition, is added to read as follows: 10.11.4 Fire Department Access Signage 10.11.4.1 Signage required by Chapter 9, Fire Code, of the Rockville City Code shall comply with requirements of the City of Rockville Fire Department Access and Signage Manual, unless otherwise permitted by the AHJ. Subparagraph 10.14.11.2.6 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 10.14.12.2.6 A fuel break of a minimum of 20 ft. (6.1 m) wide shall be cleared between a crop maze and any vehicles, buildings, or vegetation outside the maze. Paragraph 10.15.5.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 10.15.5.1 Unless otherwise approved by the AHJ, portable and vehicle-mounted generators shall only be operated outdoors a minimum of 20 ft (6.1 m) from any building openings including windows, doors and air intakes. Paragraph A.10.15.5.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: A.10.15.5.1 For the purposes of reducing the distances between the operation and refueling of portable and vehicle-mounted generators and any building or enclosure opening, including windows, doors, and air intakes, one or more of the following conditions may be considered: (1) Nature of the occupancy of the building or enclosure. (2) Expected duration of generator use. (3) Use of certified low CO emission generators. (4) Actual available distance between the generator and building or enclosure openings. (5) Installation of approved CO detection within the building or enclosure. (6) Openness of building or enclosure perimeter walls and ceiling. (7) Physical barriers or other means to deflect generator exhaust from building or enclosure openings. Section 10.16 of the NFPA 1, Fire Code, 2024 Edition, is amended by adding Subsection 10.16.6 to read as follows: 10.16.6 The AHJ shall have the authority to require that outdoor storage of any combustible material be enclosed by an approved fence or other protective enclosure to prevent unauthorized access. Subsection 10.16.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 10.16.1 Outside storage of combustible materials shall not be located within 15 ft. (4.6 m) of a property line, building, or adjacent pile of combustible material. The separation distance shall be allowed to be increased where the AHJ determines that a higher hazard to the adjoining property exists. Subsection 10.16.5 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 10.16.5 Combustible storage in the open shall not exceed 20 ft. (6.1 m) in height and 10,000 ft2 in area. Subsection 10.19.7 of the NFPA 1, Fire Code, 2024 Edition, is amended as follows: 10.19.7 Fueled Equipment. Fueled equipment, including but not limited to motorcycles, mopeds, lawn-care equipment, and portable cooking equipment, shall not be stored, operated, or repaired on any balcony, under any overhanging portion, or within a building except under one of the following conditions: (1) The building or room has been constructed for such use in accordance with the building code. (2) The use is allowed by other provisions of this Code. Subsection 10.21.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 10.21.1 Where one or more powered micromobility devices will be charged inside or within 15 ft (4.6 m) of a building or structure, the charging operation shall be in accordance with Section 10.21. Subsection 10.21.4(3) of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 10.21.4 * * * (3) Storage of combustible materials, combustible waste, or hazardous materials shall not be permitted within 15 ft (4.6 m) of the charging equipment. Section 11.1 of the NFPA 1, Fire Code, 2024 Edition, is amended by adding Subsection 11.1.7.1.2 to read as follows: 11.1.7.1.2 In new buildings, excluding one- and two- family dwellings, if the Main Electrical Service Equipment Room does not have direct exit to grade, a shunt trip to disconnect the electrical service to the building must be provided as follows: (a) In the fire Command Center, where a Fire Command Center is in the building (b) At the fire alarm annunciator, where there is no Fire Command Center (c) In an appropriately sized and weatherproof fire department access box on the address side of the building where there is no fire alarm annunciator or Fire Command Center. In existing buildings, excluding one- and two- family dwellings, where there are significant upgrades to the building electrical service, such as modifying or replacing the switchgear, a disconnecting means must be provided as for new installations. Section 11.1 of the NFPA 1, Fire Code, 2024 Edition, is amended by adding Subsection 11.1.9 to read as follows: 11.1.9 Clearance. A clear space of not less than 30 in. (762 mm) in width, 36 in. (914 mm) in depth and 78 in. (1981 mm) in height shall be provided in front of electrical service equipment. Where the electrical service equipment is wider than 30 in. (762 mm), the clear space shall not be less than the width of the equipment. No storage of any materials shall be located within the designated clear space. Exception: Where other specialized dimensions are required or permitted by NFPA 70. Paragraph 11.1.5.6 of the NFPA 1, Fire Code, 2024 Edition, is amended to delete existing wording and read as follows: 11.1.5.6. Extension cords shall not be used as a substitute for permanent wiring. Paragraph 11.1.7.3 of the NFPA 1, Fire Code, 2024 Edition, is amended by adding Subparagraph 11.1.7.3.2 as follows: 11.1.7.3.2 Doors to electrical control panel rooms shall be marked with a plainly visible and legible sign stating ELECTRICAL ROOM or similar approved wording in contrasting letters no less than 1 in. (25 mm) high and not less than ¼ in. (6.4 mm) in stroke width. Paragraph 11.3.6.1 of the NFPA 1, Fire Code, 2024 Edition, is amended by adding Subparagraph 11.3.6.1.1 to read as follows: 11.3.6.1.1 All fire service elevator keys within the jurisdiction shall be uniform and specific for the jurisdiction. All new keys for new elevators shall be cut to a uniform key code to comply with the Maryland State Elevator Code. Subsection 11.9.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 11.9.1 The fire command center shall have a door directly to the exterior of the building on the address side. The exterior door to the fire command center shall be within 50 feet of the fire department access road. A fire department access box shall be provided within 6 feet of the exterior door to the command center. The exterior door to the fire command center shall be identified on the exterior face as the fire command center in a manner acceptable to the fire official. Paragraph 11.10.2* of the NFPA 1, Fire Code, 2024 Edition, is amended by adding Subparagraph 11.10.2.1 to read as follows: 11.10.2.1 All newly constructed below-ground floors of a building, all floors in buildings greater than 25,000 sq. ft per floor, and all floors of buildings greater than three (3) stories in height must meet minimum emergency radio communication system performance criteria adopted by Montgomery County Department of Technology Services. Proof that minimum performance criteria are met must be provided in writing to the AHJ, and testing shall comply with the following: (a) Performance testing shall be performed in accordance with the technical standards for systems and testing personnel established by Montgomery County Department of Technology Services. (b) Compliance testing shall be performed at the time of occupancy and annually thereafter. (c) All testing, design, installation and maintenance required must be performed by personnel approved by the City of Rockville Fire Marshal. Exception: The requirements of this section shall not apply to one- and two-family dwellings or townhomes. Paragraph 12.6.9.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to add Subparagraph: 12.6.9.1 Unless otherwise approved by the AHJ, Christmas tree placement within buildings shall comply with 12.6.9.1. Subsection 12.6.9.1 of the NFPA 1, Fire Code, 2024 Edition, is amended by adding Paragraph 12.6.9.2 as follows: 12.6.9.2 The AHJ shall: (1) Approve the placement of a natural cut or balled tree; (2) Limit the number of natural cut or balled trees displayed; and (3) Order the removal of any tree if the tree poses a hazard to life or safety. Paragraph 12.6.9.5 of the NFPA 1, Fire Code, 2024 Edition, is amended to add Subparagraph 12.6.9.5.3: 12.6.9.5.3 Combustible artificial decorative vegetation shall be tested by a laboratory recognized by the Office of the State Fire Marshal. Subsection 12.6.9.6.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 12.6.9.6.1 Where a natural cut tree is permitted, the bottom end of the trunk shall be cut off with a straight fresh cut at least 2 in. (50 mm) above the end prior to placing the tree in a stand to allow the tree to absorb water. A natural cut tree shall not exceed 10 ft. (3 m) in height, excluding the tree stand. Paragraph 13.1.9 of the NFPA 1, Fire Code, 2024 Edition, is amended by adding Subparagraph 13.1.9.1 as follows: 13.1.9.1(1) Where a required fire protection system is impaired or out of service for more than four (4) hours in a twenty-four (24) hour period, mitigating measures shall be in accordance with Section 9-14 of the Rockville City Code. (2) Fire sprinkler systems impaired or out of service for more than ten (10) hours in a twenty-four (24) hour period, mitigating measures shall be in accordance with Section 9-14 of the Rockville City Code. Section 13.1 is amended to add the following Subsection 13.1.14. 13.1.14 Appearance of Equipment. The AHJ shall be permitted to prohibit any device that has the physical appearance of a life safety or fire protection function but does not perform that life safety or fire protection function. Paragraph 13.1.3.1 is amended to read as follows: 13.1.3.1 Basic Testing. Where required by the AHJ Chapters 11 through 43 of NFPA 101, installations involving two or more integrated fire protection or life safety systems shall be tested to verify the proper operation and function of such systems in accordance with 13.1.3.1.1 and 13.1.3.1.2. [101:9.11.4.1] Paragraph 13.1.3.2 is amended to read as follows: 13.1.3.2*NFPA 4 Testing. Where required by the AHJ or 9.3.5 or Chapters 11 through 43 of NFPA 101, the following integrated fire protection and life safety systems shall be tested in accordance with 13.1.3.1 and 13.1.3.2.1 through 13.1.3.2.2: (1) Integrated fire protection and life safety systems in high-rise buildings (2) Integrated fire protection and life safety systems that include a smoke control system [101:9.11.4.2] Paragraph 13.2.2.2 of the NFPA 1, Fire Code, 2024 Edition, is amended by deleting the existing wording and replaced to read as follows: 13.2.2.2 All new buildings shall be equipped with an approved standpipe system where required by Chapter 5, Buildings and Building Regulations, of the Rockville City Code. Where a Class III system is required, a Class I system shall be installed. Paragraph 13.3.1.2 of the NFPA 1, Fire Code, 2024 Edition, is amended by adding Subparagraph 13.3.1.2.1 to read as follows: 13.3.1.2.1 For new ceiling installations, drop-out ceilings as referenced in NFPA 13, Subsection 9.3.11 and NFPA 13R, Section 6.15 shall be prohibited. Paragraph 13.3.2.1 of the NFPA 1, Fire Code, 2024 Edition, is amended by adding Subparagraph 13.3.2.1.1 to read as follows: 13.3.2.1.1 All new buildings shall be equipped with an automatic sprinkler system or other automatic fire suppression system where required by Chapter 5, Buildings and Building Regulations, of the Rockville City Code. Paragraph 13.3.2.5.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read: 13.3.2.5.1 The following assembly occupancies having an occupant load of 100 or more persons, or 5,000 or more square feet in area, or located on a floor or other than the level of exit discharge shall be protected throughout by an approved, electrically supervised automatic sprinkler system in accordance with 13.3.1.2: (1) Dance halls (2) Discotheques (3) Nightclubs (4) Bars (5) Restaurants (6) Assembly occupancies with festival seating [101:12.3.5.1] Subparagraph 13.3.2.24.2 of the NFPA 1, Fire Code, 2024 Edition is deleted and replaced with the following: 13.3.2.24.2* Existing high-rise buildings, other than those meeting 13.3.2.24.2.1 or 13.3.2.24.2.2, shall be protected throughout by an approved automatic sprinkler system in accordance with this chapter and 13.3.2.24.2.3 through 13.3.2.24.2.5 13.3.2.24.2.1 An automatic sprinkler system shall not be required where every dwelling unit has exterior exit access in accordance with 14.10.3. 13.3.2.24.2.2 An automatic sprinkler system shall not be required in buildings that have a previously approved and implemented engineered life safety system complying with 13.3.2.24.2.2.1 and 13.3.2.24.2.2.2. 13.3.2.24.2.2.1 The engineered life safety system shall have been developed by a registered professional engineer experienced in fire and life safety system design, approved by the authority having jurisdiction, and inspected for compliance by the authority having jurisdiction, and shall include any or all of the following: (1) Partial automatic sprinkler protection (2) Smoke detection systems (3) Smoke control systems (4) Compartmentation (5) Other approved systems 13.3.2.24.2.2.2 The engineered life safety system shall be maintained in accordance with the approved design documents and applicable standard. 13.3.2.24.2.3 Each building owner shall, within 180 days of receiving notice, file an intent to comply with this regulation with the AHJ for approval. 13.3.2.24.2.4 The AHJ shall review and respond to the intent-to-comply submittal within 60 days of receipt. 13.3.2.24.2.5* The entire building shall be required to be protected by an approved automatic sprinkler system within 12 years of the date of the original violation notice issued by the fire authority having jurisdiction. 13.3.2.24.2.6 Public Disclosure Signage. In high-rise buildings that are not protected throughout by an approved automatic sprinkler system, signage shall be posted complying with 13.3.2.24.2.6(A) through 13.3.2.24.2.6(D). (A) Signage shall be posted at all main building entrances as approved by the AHJ. (B) The lettering on the sign shall be at least 1 inch (25 millimeters) high. (C) The lettering shall be placed on a contrasting background. (D) The wording shall state as follows: "WARNING: THIS HIGH-RISE BUILDING IS NOT PROTECTED THROUGHOUT WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM". Annex section A13.3.2.24.2.3 of the NFPA 1, Fire Code, 2024 Edition, is amended to replace "A.13.3.2.24.2.3" with "A.13.3.2.24.2.5" Subparagraph 13.2.25.5 of the NFPA 1, Fire Code, 2024 Edition is amended to delete existing wording and read as follows: 13.3.2.25.5 An automatic sprinkler system shall be installed throughout all mini-storage building fire areas greater than 2500 feet 2 (232 meters 2 ) and where any of the individual storage units are separated by less than a 1-hour fire resistance-rated barrier. Fire areas shall be defined by approved fire barriers having a fire resistance rating of not less than 3-hours. [5000: 30.3.5.4] Subparagraph 13.3.2.27.1.1 of the NFPA 1, Fire Code, 2024 Edition is amended to add the following: 13.3.2.27.1.1 All new day care occupancies shall be protected throughout by an approved, supervised automatic sprinkler system in accordance with Section 9.7 of NFPA 101. [101:16.3.5.1] Automatic sprinkler protection is not required if all of the following conditions are met: (1) The total number of occupants in the occupancy in which the day care center is located is not more than 300 persons. (2) All rooms used for day care are located on the level of exit discharge; (3) All rooms used for day care have at least one exterior exit door at grade level; (4) The occupancy in which the day care center is located does not exceed 12,000 sq. ft. in area. Paragraph 13.3.3.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 13.3.3.1 A sprinkler system shall be properly maintained to provide at least the same level of performance and protection as designed. The owner shall be responsible for maintaining the system and keeping it in good working condition. Paragraph 13.3.3.2 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 13.3.3.2 A sprinkler system shall be inspected, tested, and maintained in accordance with NFPA 25. Subsection 13.4.1 of the NFPA 1, Fire Code, 2024 Edition, is amended by adding Subparagraph 13.4.1.1.1 to read as follows: 13.4.1.1.1 No fire pump component, including the pump, driver, or controller, shall be permitted to be installed in below ground vaults or pits unless otherwise approved by the AHJ. Paragraph 13.6.1.2 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 13.6.1.2* Where Required. Fire extinguishers shall be provided where required by this Code as specified in Table 13.6.1.2 and the referenced codes and standards listed in Chapter 2 unless otherwise permitted by the AHJ. Sub-subparagraph 13.6.4.1.2.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 13.6.4.1.2.1 Persons performing maintenance and recharging of extinguishers shall be licensed as required by the AHJ. Sub-subparagraph 13.6.4.1.2.1.1 of the NFPA 1, Fire Code, 2024 Edition, is deleted. Sub-subparagraph 13.6.4.1.2.1.2 of the NFPA 1, Fire Code, 2024 Edition, is deleted. Sub-subparagraph 13.6.4.1.2.1.3 of the NFPA 1, Fire Code, 2024 Edition, is deleted. Sub-subparagraph 13.6.4.1.2.1.4 of the NFPA 1, Fire Code, 2024 Edition, is deleted. Sub-subparagraph 13.6.4.1.2.1.5 of the NFPA 1, Fire Code, 2024 Edition, is deleted. Sub-subparagraph 13.6.4.1.2.1.6 of the NFPA 1, Fire Code, 2024 Edition, is deleted. Sub-subparagraph 13.6.4.1.2.3 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 13.6.4.1.2.3 Persons performing inspections shall not be required to be licensed. Subparagraph 13.7.1.7.6 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 13.7.1.7.6 For fire alarm systems using automatic fire detection or waterflow detection devices to initiate the fire alarm system in accordance with Chapters 11 through 43 of NFPA 101, not less than one manual fire alarm box, located as required by the AHJ, shall be provided to initiate a fire alarm signal. [101:9.6.2.6] This paragraph does not permit the omission of manual fire alarm boxes in accordance with other provisions of this Subsection unless specifically permitted by NFPA 101 Chapters 11 through 43. Subparagraph 13.7.1.15.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 13.7.1.15.1 Where required by the AHJ and another section of this Code, a risk analysis for mass notification systems shall be provided in accordance with the requirements of Chapter 24 of NFPA 72. [101:9.14.1] Sub-subparagraph 13.7.2.5.6.4 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 13.7.2.5.6.4 Single-station or multiple-station smoke alarms or smoke detectors shall be provided in all rooms used for sleeping in accordance with 13.7.1.8. [101:16.6.3.4.4] For compliance with NFPA 101, Paragraph 43.7.2.1(2), approved battery-powered smoke alarms, rather than house electrical service-powered smoke alarms shall be permitted where the facility has testing, maintenance, and smoke alarm replacement programs that ensure reliability of power to the smoke alarms. Sub-subparagraph 13.7.2.6.6.5 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: Approved battery-powered smoke alarms, rather than house electrical service-powered smoke alarms required by 13.7.2.6.6.4, shall be permitted where the facility has testing, maintenance, and smoke alarm replacement programs that ensure reliability of power to the smoke alarms. [101:17.6.3.4.5] Sub-subparagraph 13.7.2.22.8.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 13.7.2.22.8.1 All living areas, as defined in 3.3.24.5 of NFPA 101, and all corridors shall be provided with smoke detectors that comply with NFPA 72 and are arranged to initiate an alarm that is audible in all sleeping areas, as modified by 13.7.2.22.8.3. [101:33.3.3.4.8.1] Sub-subparagraph 13.7.2.22.8.2 of the NFPA 1, Fire Code, 2024 Edition, is deleted. Sub-subparagraph 13.7.2.28.1.2 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 13.7.2.28.1.2 Storage occupancies less than three (3) stories with ordinary or high hazard contents not exceeding an aggregate floor area of 100,000 ft 2 (9,300 m 2 ) shall not be required to have a fire alarm system. Sub-subparagraph 13.7.2.28.1.3 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 13.7.2.28.1.3 Storage occupancies less than three (3) stories protected throughout by an approved automatic sprinkler system in accordance with Section 13.3 shall not be required to have a fire alarm system. Paragraph 14.4.2.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to add the following sub-paragraph, 14.4.2.1.1: 14.4.2.1.1 Trash or recyclable materials awaiting scheduled collection shall not be placed in exits, exit access corridors or on egress balconies. Sub-paragraph 14.5.2.3.7 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 14.5.2.3.7 Two releasing motions shall be permitted for existing hardware on a door leaf serving an area having an occupant load not exceeding three, provided that releasing does not require simultaneous operations. [101:7.2.1.5.3.7] The locking device shall be of a type that is readily distinguishable as locked. Sub-paragraph 14.5.2.3.8 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 14.5.2.3.8 Two releasing motions shall be permitted in existing educational occupancies in accordance with 15.2.2.2.4 of NFPA 101 and in existing day care occupancies in accordance with 17.2.2.2.6 of NFPA 101. [101:7.2.1.5.3.8] The locking device shall be of a type that is readily distinguishable as locked. Sub-paragraph 14.5.3.4.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 14.5.3.4.1 Where permitted by the AHJ and in Chapters 11 through 43 of NFPA 101, door assemblies separating the elevator lobby from the exit access required by 14.9.1.6.1 shall be permitted to be electrically locked, provided that all the following criteria are met: (1) Door electromechanical or electromagnetic locking hardware is listed in accordance with UL 294, Access Control System Units, or UL 1034, Burglary-Resistant Electric Locking Mechanisms. (2) The building is protected throughout by a fire alarm system in accordance with Section 13.7. (3) The building is protected throughout by an approved, supervised automatic sprinkler system in accordance with Section 13.3. (4) Waterflow in the sprinkler system required by 14.5.3.4.1 is arranged to initiate the building fire alarm system. (5) The elevator lobby is protected by an approved, supervised smoke detection system in accordance with Section 13.7. (6) Detection of smoke by the detection system required by 14.5.3.4.1 is arranged to initiate the building fire alarm system and notify building occupants. (7) Initiation of the building fire alarm system by other than manual fire alarm boxes unlocks the electrical locks on the elevator lobby door assembly. (8) Loss of power to the elevator lobby electrical lock system unlocks the electrical locks on the elevator lobby door assemblies. (9) Once unlocked, the elevator lobby door assemblies remain electrically unlocked until the building fire alarm system has been manually reset. (10) Where the elevator lobby door assemblies remain mechanically latched after being electrically unlocked, latch-releasing hardware in accordance with 14.5.2.3 is affixed to the door leaves. (11) A two-way communication system is provided for communication between the elevator lobby and a central control point that is constantly staffed. (12) The central control point staff required by 14.5.3.4.1 is capable, trained, and authorized to provide emergency assistance. [101:7.2.1.6.4.1] Sub-paragraph 14.5.3.5.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 14.5.3.5.1 Where a side-hinged door assembly, a pivoted-swinging door assembly, or a balanced door assembly is equipped with panic or fire exit hardware, such hardware shall meet all of the following criteria: (1) It shall consist of a cross bar or a push pad, with the length of the actuating portion of the cross bar or push pad extending not less than one-half of the width of the door leaf measured from the latch stile unless otherwise required by 14.5.3.5.2. (2) It shall be mounted as follows: (a) New installations shall be not less than 34 in. (865 mm) and not more than 48 in. (1220 mm) above the floor. (b) Existing installations shall be not less than 30 in. (760 mm) and not more than 48 in. (1220 mm) above the floor. (3) It shall be constructed so that a horizontal force not to exceed 15 lbf (66 N) actuates the cross bar or push pad and latches. [101:7.2.1.7.1] Sub-paragraph 14.5.3.5.4 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 14.5.3.5.4 Panic hardware and fire exit hardware, in other than detention and correctional occupancies as otherwise provided in Chapters 22 and 23 of NFPA 101, shall not be equipped with any locking device, set screw, or other arrangement that prevents the release of the latch when pressure is applied to the releasing device. [101:7.2.1.7.4] Subsection 14.5.8 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 14.5.8 Door Openings in Folding Partitions. Where permanently mounted folding or movable partitions divide a room into smaller spaces, a swinging door leaf or open doorway shall be provided as an exit access from each such space, unless otherwise specified in 14.5.8.2. [101:7.2.1.12] Paragraph 14.5.8.1 of the NFPA 1, Fire Code, 2024 Edition, is deleted. Sub-paragraph 14.5.10.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 14.5.10.1 Where required by the AHJ and Chapters 11 through 43 of NFPA 101, the following door assemblies shall be inspected and tested not less than annually in accordance with 14.5.10.2 through 14.5.10.7: (1) Door leaves equipped with panic hardware or fire exit hardware in accordance with 14.5.3.5 (2) Door assemblies in exit enclosures (3) Door hardware release of electrically locked egress door assemblies (4) Door assemblies with special locking arrangements subject to 14.5.3.4 [101:7.2.1.14.1] Paragraph 14.13.1.2 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 14.13.1.2 For the purposes of 14.13.1.1, exit access shall include, but not be limited to designated stairs, aisles, corridors, ramps, escalators, and passageways leading to an exit. For the purposes of 14.13.1.1, exit discharge shall include only designated stairs, ramps, aisles, walkways, and escalators leading to a public way. Subparagraph 18.2.2.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 18.2.2.1 Access Box(es). All occupancies, other than one- and two-family dwellings, that have fire protection or life safety systems installed shall provide an approved access box. 18.2.2.1.1 An access box shall not be required for occupancies providing a 24-hour on-site staffing with access to all areas in the building or complex. At least one person shall staff a fixed location proximate to the main building or complex entrance to provide ready access for the fire department. 18.2.2.1.2 For multiple occupancies located within a single structure, a single access box shall be permitted with approval of the authority having jurisdiction. 18.2.2.1.3 For multiple structures within a residential building complex, a single access box shall be permitted with approval of the authority having jurisdiction. 18.2.2.1.4 The size, contents, and location of the access box shall be determined by the Rockville Fire Marshal in cooperation with the occupancy owner or management. Subparagraph 18.2.3.2.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 18.2.3.2.1 A fire department access road shall extend to within 50 ft. (15 m) of at least one (1) exterior door acceptable to the AHJ that can be opened from the outside and that provides access to the interior of the building. Sub-subparagraph 18.2.3.5.1.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to add the following sub-subparagraphs: 18.2.3.5.1.1.1 Fire apparatus access roads shall have an unobstructed width of not less than 20 ft (6.1 m). (A) On-street parking is allowed on one side if the load-bearing fire department access road is at least 28 ft. (8.53 m) wide. (B) On-street parking is allowed on both sides if the load-bearing fire department access road is at least 36 ft. (10.97 m) wide. Sub-subparagraph 18.2.3.5.1.2 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 18.2.3.5.1.2 Vertical clearance for any overhead obstruction over streets classified by Section 21-21 of the Rockville City Code as Limited Access, Major, or Arterial, shall be at least 16 ft. (4.88 m) from the finished surface. Subparagraph 18.2.3.5.2 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 18.2.3.5.2 Surface. Fire Department access roads shall be designed and maintained to support the imposed loads of fire apparatus and shall be provided with an all-weather driving surface as approved by the AHJ. Sub-subparagraph 18.2.3.5.3.1 of the NFPA 1, Fire Code, 2024 Edition, is added to read as follows: 18.2.3.5.3.1 Turning Radii. Turning radii for fire department access road shall comply with the following: (1) The minimum interior turning radius for a fire department access road is 25 ft. (7.62 m). (2) The minimum exterior turning radius for a fire department access road is 50 ft. (15.24 m). (3) Performance-based approval of alternative turning radii may be permitted if apparatus movement into opposing lanes of traffic is minimized and an unrestricted fire department access road is maintained. Subparagraph 18.2.3.5.4 of the NFPA 1, Fire Code, 2024 Edition, is amended by adding Sub-subparagraphs 18.2.3.5.4.1 and 18.2.3.5.4.2 to read as follows: 18.2.3.5.4.1 Cul-de-sacs used to provide a dead end apparatus turn-around shall not be less than 90-ft. (27.43 m) in diameter at the closed end. 18.2.3.5.4.2 Hammerhead or T-turnarounds used to provide a dead-end apparatus turn-around shall have legs not less than 60-ft. (18.29 m) long and all portions of the hammerhead or T-turnaround not less than 20-ft. (6.1 m) wide. Paragraph 18.2.3.6 of the NFPA 1, Fire Code, 2024 Edition, is amended by adding Subparagraph 18.2.3.6.1.1 to read as follows: 18.2.3.6.1.1 Approved signs or other approved notices required by 18.2.3.5.1 shall comply with requirements of the City of Rockville Fire Department Signage Manual. Subsection 18.4.1 of the NFPA 1, Fire Code, 2024 Edition, is amended by adding the following Paragraphs to read as follows: 18.4.1.3 Fire flow requirements shall be met using fire hydrants located not further than 2000 ft. (610 m) from the building or structure being served. 18.4.1.3.1 Measurements to determine compliance with the requirements of 18.4.1.2.1 shall be made along a path or route accessible to fire department personnel Section 18.5 of the NFPA 1, Fire Code, 2024 Edition, is amended by adding Paragraph 18.5.1.7 and Subparagraphs 18.5.1.7.1 and 18.5.1.7.2 to read as follows: 18.5.1.7 Fire hydrants shall be spaced not greater than 300 ft. (92 m) from all exterior points of the structure where the fire hose would lay on the ground, and within 400 ft. (121.92 m) from any dead ends in a fire department access road. 18.5.1.7.1 Fire hydrant spacing may be increased to 500 ft. (153 m) for structures protected throughout by an approved automatic sprinkler system, in accordance with Section 9.7 of NFPA 101, Life Safety Code, 2024 Edition. 18.5.1.7.2 Buildings and structures equipped with a sprinkler system and/or a standpipe system shall have a fire hydrant located within 100 ft. (30.48 m) of the fire department connection. The distance shall be measured along a path accessible to foot travel. Paragraph 18.5.2 of the NFPA 1, Fire Code, 2024 Edition, is deleted. Paragraph 18.5.3 of the NFPA 1, Fire Code, 2024 Edition is deleted. Paragraph 18.5.10.3 of the NFPA 1, Fire Code, 2024 Edition, is amended to read and by adding the following Paragraph, Subparagraphs, and Annex Section to read as follows: 18.5.10.3 The provisions of this subsection shall apply to all private fire hydrants and, when authorized by their respective owners, all fire hydrants owned by the City of Rockville and WSSC. 18.5.10.3.1 A reflective paint or tape marker at least 2 in. (25 mm) shall be placed around the neck, immediately below the bonnet of each, on each fire hydrant. 18.5.10.3.2 If the fire hydrant is manufactured where a band cannot be applied to the neck of the fire hydrant, the reflective paint or tape marker shall be applied to the rim of the bonnet. 18.5.10.3.3* The color of the bonnet, three (3) outlets, and barrel shall be as follows: CAPACITY | COLOR <500 gpm | Safety Red 500 - 999 gpm | Safety Orange 1,000 - 1,500 gpm | Safety Green >1,500 gpm | Safety Blue All Barrels | Safety Red A.18.5.10.3.3 The City of Rockville Department of Public Works uses the following paint to identify their fire hydrants: COLOR | RUSTOLEUM ITEM # Safety Red | K7764402 Safety Orange | 3455402 Safety Green | 3433402 Safety Blue | K7725402 Subparagraph 20.1.5.8.3 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 20.1.5.8.3 In the following assembly occupancies, an audible announcement shall be made, or a projected image shall be shown, within 10 minutes prior to the start of each program that notifies occupants of the location of the exits to be used in case of a fire or other emergency: (1) Theaters (2) Motion picture theaters (3) Auditoriums (4) Other similar assembly occupancies with occupant loads exceeding 300 where there are non-continuous programs [101:12.7.7.3; 101:13.7.7.3] Subparagraph 20.2.4.2.3 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 20.2.4.2.3 Fire emergency egress drills shall be conducted as follows: (1) Not less than one fire emergency egress drill shall be conducted every month the facility is in session, unless the following criteria are met: (a) In climates where the weather is severe, the monthly fire emergency egress drills shall be permitted to be deferred; and (b) In educational occupancies which are: (i) fully protected by an automatic sprinkler system, the total number of annual fire emergency egress drills shall be five, with a least two of the required drills conducted in the first four months of the school year; or (ii) not fully protected by an automatic sprinkler system, the total number of annual fire emergency egress drills shall be eight, with at least three of the required drills conducted in the first four months of the school year. (2) All occupants of the building shall participate in the fire emergency egress drill. (3) One fire emergency egress drill, other than for educational occupancies that are open on a year-round basis, shall be required within the first 30 days of operation. Subparagraph 20.3.4.1.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 20.3.4.1.1 In new day-care homes, the requirements of Section 16.6 of NFPA 101 shall apply to day-care homes in which not more than twelve (12) clients receive care, maintenance, and supervision by other than their relative(s) or legal guardian(s) for less than twenty-four (24) hours per day, generally within a dwelling unit. (See also 16.6.1.4 of NFPA 101.) Paragraph 25.2.2.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 25.2.2.1 All tent fabric shall meet the flame propagation performance criteria contained in NFPA 701, Standard Methods of Fire Tests for Flame Propagation of Textiles and Films or other approved testing standard approved by the State Fire Marshal. Paragraph 26.1.6 of the NFPA 1, Fire Code, 2024 Edition, is amended by adding the following: 26.1.6.2 When requested by the AHJ, a hazard assessment shall be conducted by a technically qualified person acceptable to the AHJ. 26.1.6.3 When requested by the AHJ, a list of hazardous materials used in each laboratory shall be provided. The list shall specify the chemical name, quantity and hazard class. 26.1.6.4 New laboratories or laboratories where the NFPA 45 laboratory hazard classification changes shall post an information placard near the main entrance to the laboratory. The placard shall state the building name or address, room number, NFPA 45 laboratory hazard classification, edition of NFPA 45, maximum allowable quantities of flammable liquids both inside a storage cabinet and open use, and maximum quantities of flammable gases permitted within the laboratory. Subparagraph 31.3.6.2.2 of the NFPA 1, Fire Code, 2024 Edition, is amended by adding item (9) to read as follows: (9) Piles containing leaves and other extraneous or hogged material, such as whole tree chip piles, shall be turned or reclaimed at least every three (3) months. Subparagraph 31.3.6.3.1 of the NFPA 1, Fire Code, 2024 Edition, is deleted and amended to read as follows: 31.3.6.3.1 Piles may not exceed 18 ft. (5.49 m) in height, 50 ft. (15.24 m) in width, and 350 ft. (106.68 m) in length. Piles shall be subdivided by fire lanes having at least 25 ft. (7.62 m) of clear space at the base of piles. Subparagraph 31.3.6.3.2 of the NFPA 1, Fire Code, 2024 Edition, is deleted. Sub-subparagraph 31.3.6.3.2.1 of the NFPA 1, Fire Code, 2024 Edition, is deleted. Sub-subparagraph 31.3.6.3.2.2 of the NFPA 1, Fire Code, 2024 Edition, is deleted. Sub-subparagraph 31.3.6.3.2.3 of the NFPA 1, Fire Code, 2024 Edition, is deleted. Paragraph 32.9.3.7 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 32.9.3.7 Emergency Instruction to Audience. When an audience is present, an announcement shall be made within 10 minutes of the start of each program notifying the audience of the following: (1) The location of exits to be used in case of fire or other emergency (2) The means that will be used to notify the audience of fire or other emergency [140:4.10.7] Paragraph 34.1.3 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 34.1.3 Approved Storage Floor Plan. Where required by the AHJ, an approved storage floor plan that documents the permissible use of the storage area, based on the occupancy classification and the design basis of the automatic sprinkler system, shall be provided and mounted in an approved location. Section 34.6 of the NFPA 1, Fire Code, 2024 Edition, is amended to add new Paragraph 34.6.7 and subparagraphs 34.6.7.1 and 34.6.7.2 as follows: 34.6.7 Standpipe systems shall be installed in all storage buildings having an area of 300,000 sq. ft. or more. 34.6.7.1 Standpipe systems shall comply with Section 13.2 and NFPA 14. 34.6.7.2 Class I hose connections shall be provided at each of the following locations: (1) In each exit passageway at the entrance from the storage area into the passageway; (2) Within every required exit stairwell; (3) At other locations such that all points of the storage area floor are within 200 ft. of a hose connection, unless otherwise required by the AHJ. Chapter 35 Animal Housing Facilities of the NFPA 1, Fire Code, 2024 Edition is deleted. Paragraph 42.7.5 of the NFPA 1, Fire Code, 2024 Edition, is amended by adding Paragraph 42.7.5.7, Paragraph 42.7.5.8, and Paragraph 42.7.5.9 to read as follows: 42.7.5.7 Management/owner officials or employees shall conduct daily site visits to ensure that all equipment is operating properly. 42.7.5.8 Regular equipment inspection and maintenance at the unattended self-service facility shall be conducted. 42.7.5.9 Fuel dispensing equipment shall comply with one of the following: (1) The amount of fuel being dispensed is limited in quantity by preprogrammed card; or (2) Dispensing devices shall be programmed or set to limit uninterrupted fuel delivery of not more than 25 gal. (94.64 L) and shall require a manual action to resume continued delivery. Subparagraph 42.7.5.5 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 42.7.5.5 A telephone or other approved, clearly identified means to notify the fire department shall be provided on the site in a location approved by the AHJ. The following information shall be conspicuously posted in this area: (1) The exact address of the unattended self-service facility. (2) The telephone number of the owner or operator of the unattended self-service facility. Subsection 50.8.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to add the following Paragraphs, Subparagraphs, and Sub-subparagraphs: 50.8.1.7 Commercial Outdoor Cooking Operations. These requirements apply to commercial outdoor cooking operations such as those that typically take place under a canopy or tent type structure at fairs, festivals and carnivals. This includes but is not limited to deep-frying, sautéing and grilling operations. 50.8.1.7.1 LP Gas Fuel Requirements 50.8.1.7.1.1 LP gas tank size shall be limited to 60 lbs. The total amount of LP gas on site shall not exceed 60 lbs. for each appliance that is rated not more than 80,000 btu/hr. and 120 lbs. for each appliance rated more than 80,000 btu/hr. 50.8.1.7.1.2 Tanks must be maintained in good physical condition and shall have a valid hydrostatic date stamp. 50.8.1.7.1.3 Tanks shall be secured in their upright position with a chain, strap or other approved method that prevents the tank from tipping over. 50.8.1.7.1.4 Tanks shall be located so that they are not accessible to the public. LP gas tanks shall be located at least 5 ft. (1.52 m) from any cooking or heating equipment or any open flame device. 50.8.1.7.1.5 All LP gas equipment shall be properly maintained and comply with the requirements of NFPA 58. 50.8.1.7.1.6 Regulators. Single-stage regulators may not supply equipment that is rated more than 100,000 btu/hr. rating. Two-stage regulators shall be used with equipment that is rated more than 100,000 btu/hr. 50.8.1.7.2 General Safety Requirements. 50.8.1.7.2.1 All electrical cords shall be maintained in a safe condition and shall be secured to prevent damage. 50.8.1.7.2.2 Movable cooking equipment shall have wheels removed or shall be placed on blocks or otherwise secured to prevent movement of the appliance during operation. 50.8.1.7.2.3 Portable fire extinguishers shall be provided in accordance with NFPA 1, Section 13.6 and shall be specifically listed for such use. 50.8.1.8 There shall be no obstructions or impediments to immediate escape from vehicles or other mobile units used for cooking operations. 50.8.1.9 Seating for the public shall not be located within any mobile or temporary cooking vehicle. Subsection 50.8.3 of the NFPA 1, Fire Code, 2024 Edition, is deleted and replaced with the following: 50.8.3 Tent and Canopy Requirements 50.8.3.1 Temporary cooking operations conducted in tents and under canopies shall comply with NFPA 102 and Chapter 25. 50.8.3.2 All tent and canopy material shall comply with the flame resistance requirements of Section 25.2.2. 50.8.3.3 Tents or canopies where cooking equipment are not protected in accordance with NFPA 96 is located shall not be occupied by the public. 50.8.3.4 Tents or canopies where cooking equipment not protected in accordance with NFPA 96 is located shall be separated from other tents, canopies, structures, or vehicles by a minimum of 10 feet (3050 millimeters) unless otherwise approved by the AHJ. Subparagraph 50.8.8.3.2 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 50.8.8.3.2 Disconnected LP-Gas containers and LP-Gas cylinders for purposes other than engine fuel systems shall be secured in an upright position during transport and storage. [96:17.8.4.2] Section 60.1 of the NFPA 1, Fire Code, 2024 Edition, is amended by adding Subsection 60.1.8 and Paragraph 60.1.8.1 to read as follows: 60.1.8 Permits. 60.1.8.1 A Hazardous Materials Use Permit, issued by Montgomery County, shall be required to dispense, handle, use, process, transfer, store, or manufacture one or more materials or substances that meet the requirements of a "hazardous substance" per Montgomery County Executive Regulation 3-12. Section 65.2 of the NFPA 1, Fire Code, 2024 Edition, is amended by adding Subsection 65.2.3 to read as follows: 65.2.4 All storage of display fireworks shall comply with NFPA 1124, Code for the Manufacture, Transportation, Storage, and Retail Sales of Fireworks and Pyrotechnic Articles, 2022 edition. Section 65.2 of the NFPA 1, Fire Code, 2024 Edition, is amended by adding Subsection 65.2.4 to read as follows: 65.2.4 Insurance Requirements. 65.2.4.1 The following requirements apply to public liability and property damage insurance: (1) The State and City of Rockville shall be named as an insured in the contract of insurance; (2) Because the policy shall cover all damages to persons or property, a deductible form of coverage may not be accepted; (3) The minimum amount of coverage that the State can accept on any display is $25,000 for the injury of one person, $50,000 for more than one person, and $10,000 for property damage; and (4) A duplicate policy of a certificate of insurance shall be attached to the application. 65.2.4.2 The policy or certificate shall provide that: (1) The coverage may not be canceled without at least 30 days notice to the State Fire Marshal; (2) The duplicate policy or certificate shall set forth all of the terms, conditions, endorsements, and riders which are or which will become part of the policy when issued; (3) It is understood and agreed that limitations cannot be included in the policy which are not set forth in the duplicate policy or certificate of insurance which has been filed; (4) If the policy is issued by an insurer authorized to do business in the State, it shall be validated by the signature of an agent licensed by the Maryland Insurance Administration to represent the insurer; (5) If coverage is provided by an insurer who is not authorized to do business in the State, the duplicate policy or certificate of insurance shall be accompanied by a power of attorney or other satisfactory evidence that the person, firm, or corporation acting as agent in accepting the risk has authority to bind risks and issue policies for the insurer; (6) The State Fire Marshal's Office specifically reserves the right to disapprove contracts issued by any authorized insurer if the Fire Marshal's Office determines the insurer is unsatisfactory; and (7) If the policy issued by the unauthorized company is acceptable to the Fire Marshal's Office, it shall be registered and the registration fee and tax paid. Section 65.3 of the NFPA 1, Fire Code, 2024 Edition, is amended by adding Subsection 65.3.4 to read as follows: 65.3.4 Insurance Requirements. 65.3.4.1 The following requirements apply to public liability and property damage insurance: (1) The State and City of Rockville shall be named as an insured in the contract of insurance; (2) Because the policy shall cover all damages to persons or property, a deductible form of coverage may not be accepted; (3) The minimum amount of coverage that the State can accept on any display is $25,000 for the injury of one person, $50,000 for more than one person, and $10,000 for property damage; and (4) A duplicate policy of a certificate of insurance shall be attached to the application. 65.3.4.2 The policy or certificate shall provide that: (1) The coverage may not be canceled without at least 30 days notice to the State Fire Marshal; (2) The duplicate policy or certificate shall set forth all of the terms, conditions, endorsements, and riders which are or which will become part of the policy when issued; (3) It is understood and agreed that limitations cannot be included in the policy which are not set forth in the duplicate policy or certificate of insurance which has been filed; (4) If the policy is issued by an insurer authorized to do business in the State, it shall be validated by the signature of an agent licensed by the Maryland Insurance Administration to represent the insurer; (5) If coverage is provided by an insurer who is not authorized to do business in the State, the duplicate policy or certificate of insurance shall be accompanied by a power of attorney or other satisfactory evidence that the person, firm, or corporation acting as agent in accepting the risk has authority to bind risks and issue policies for the insurer; (6) The State Fire Marshal's Office specifically reserves the right to disapprove contracts issued by any authorized insurer if the Fire Marshal's Office determines the insurer is unsatisfactory; and (7) If the policy issued by the unauthorized company is acceptable to the Fire Marshal's Office, it shall be registered and the registration fee and tax paid. Section 65.4 of the NFPA 1, Fire Code, 2024 Edition, is amended by adding Subsection 65.4.3 to read as follows: 65.4.3 Insurance Requirements. 65.4.3.1 The following requirements apply to public liability and property damage insurance: (1) The State and City of Rockville shall be named as an insured in the contract of insurance (2) Because the policy shall cover all damages to persons or property, a deductible form of coverage may not be accepted; (3) The minimum amount of coverage that the State can accept on any display is $25,000 for the injury of one person, $50,000 for more than one person, and $10,000 for property damage; and (4) A duplicate policy of a certificate of insurance shall be attached to the application. 65.4.3.2 The policy or certificate shall provide that: (1) The coverage may not be canceled without at least 30 days notice to the State Fire Marshal; (2) The duplicate policy or certificate shall set forth all of the terms, conditions, endorsements, and riders which are or which will become part of the policy when issued; (3) It is understood and agreed that limitations cannot be included in the policy which are not set forth in the duplicate policy or certificate of insurance which has been filed; (4) If the policy is issued by an insurer authorized to do business in the State, it shall be validated by the signature of an agent licensed by the Maryland Insurance Administration to represent the insurer; (5) If coverage is provided by an insurer who is not authorized to do business in the State, the duplicate policy or certificate of insurance shall be accompanied by a power of attorney or other satisfactory evidence that the person, firm, or corporation acting as agent in accepting the risk has authority to bind risks and issue policies for the insurer; (6) The State Fire Marshal's Office specifically reserves the right to disapprove contracts issued by any authorized insurer if the Fire Marshal's Office determines the insurer is unsatisfactory; and (7) If the policy issued by the unauthorized company is acceptable to the Fire Marshal's Office, it shall be registered and the registration fee and tax paid. Section 65.5 of the NFPA 1, Fire Code, 2024 Edition, is deleted. Subsection 65.9.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to read as follows: 65.9.1 The manufacture, transportation, storage, sale, and use of explosive materials shall comply with NFPA 495, Explosives Materials Code, and NFPA 498, Standard for Safe Havens and Interchange Lots for Vehicles Transporting Explosives. 65.9.2 The provisions of NFPA 495, Explosives Materials Code, shall be amended as follows: (1) Delete Sections 11.2 and 11.3. (2) Amend Section 3.3 to add the following definition: Demolition. The explosive razing of any manmade structure or any part thereof that cannot be covered with overburden or blasting mats. (3) Amend Section 4.4 to add the following new Subsection: 4.4.7 Each applicant for a Demolition Class D permit shall possess 5 years of experience in the field of demolition and shall pass the demolition examination as approved by the Office of the State Fire Marshal. Section 74.1 of the NFPA 1, Fire Code, 2024 Edition, is amended to delete subsection 74.

(Ord. No. 8-16, 6-20-16; Ord. No. 3-21, 2-22-21; Ord. No. 17-25, § I, 12-15-25)

Ask a question about Rockville law

Corpus searches the Rockville sections it holds and shows the ones that match, with their citations. Free, no sign-in.