§ 16-3.4: Grease trap requirements.

(a) The standards required herein are intended to restrict release of fats, oils and grease (FOG) into the City's wastewater system. Discharges from restaurants and food preparation establishments and from commercial and industrial facilities shall provide approved structures for pretreatment of FOGs. All new construction and changes in use, as herein regulated, shall make provisions for required pretreatment structures as evidenced by a letter of approval issued by the District, before issuance of a building permit. (b) Such discharges shall comply with these requirements by the date stipulated by the Superintendent. Discharges found in noncompliance will be subject to civil penalties and fines under § 16-10.2, including termination of service as set forth in § 16-9.9. (c) For the purposes of this Part, the words "grease trap," "grease separator," and "grease interceptor" are used interchangeably. Large, outdoor, in-ground tanks are referred to as "holding tanks." The owner shall maintain a log, approved by the Superintendent, of maintenance performed on grease traps, including date, maintenance performed, and the name of the person performing the maintenance. (d) When required by the Superintendent, the owner(s) of any property serviced by a building sewer carrying fats, oils or grease (FOG) shall install a suitable structure, together with necessary valves and other appurtenances, in the building sewer to facilitate observation, sampling, and measurement of the wastes. Such structure, when required, shall be accessibly and safely located and shall be constructed in accordance with plans approved by the Superintendent and Building Inspector. The structures for the pretreatment of wastewater containing FOG shall be sized, supplied, located, installed and maintained as required by the 2000 Uniform Plumbing Code and the Maine State Internal Plumbing Code, or as most recently adopted by the City. All pretreatment grease traps shall be installed, including ball valves and test port, as outlined in Sketch A. Unless approved by the Superintendent, an outside structure as shown in Sketch B must be installed in lieu of the internal structure described above.[1] In either case, the structure shall be installed by the owner(s) at his expense and shall be maintained by him so as to be safe and accessible at all times. (e) All food preparation establishments discharging into a public sewer shall perform such pretreatment of their discharges as the Superintendent or duly authorized employees of the District may reasonably require, including installation, use and maintenance of monitoring equipment, keeping records and reporting the results of such monitoring to the Superintendent, as described above. Such records shall be made available upon request by the Superintendent to other agencies having jurisdiction over discharges to the receiving waters. Sampling frequencies for year-round food preparation establishments shall be on a semiannual basis or as established by the Superintendent. (f) FOG shall not exceed 100 mg/l from any establishment. (g) Use of enzymes alone is not acceptable as a FOG treatment method. The Superintendent may grant permits for combined enzyme/bacteria treatment methods, where only a sufficient amount of enzymes is used to act as a catalyst for the bacteria. The Superintendent may require use of bioremediation, with or without an automatic feed system, at any location where, in the Superintendent's judgment, a combined enzyme/bacteria or other treatment method is or will be inadequate as a FOG treatment method. (h) Food preparation businesses and other FOG dischargers must obtain a grease trap permit from the Superintendent prior to discharge, or prior to the expiration date of any previously issued permit. Permits are valid for two years from the date of approval and are not transferable. Each business for which a grease trap permit is required shall be charged a fee for such permit in an amount established by the City. The City will conduct random tests in permitted businesses. In the event a discharge sample exceeds the above 100 mg/l limitation, the owner of the food preparation business or other FOG discharger will be billed the cost for sampling and retesting. Such a failure on two consecutive tests shall constitute a violation of this Part. A change in ownership of the food preparation business or other FOG discharger requires a new application, permit and fee. Applications for renewal of grease trap permits must be submitted 60 days prior to expiration date of the existing permit. The permit application can be obtained from the Superintendent.

[ Ord. of 5-5-2008 ]

Ask a question about Old Town law

Corpus searches the Old Town sections it holds and shows the ones that match, with their citations. Free, no sign-in.