For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 10-3 — Amendments

Code of Ordinances, City of Portland, Maine (Chapters as revised by the City Clerk, latest revision September 9, 2026 (each chapter carries its own revision date)) · Portland Code of Ordinances § 10-3

Corpus is an independent public-information project, not the official City of Portland website. Stable reference: corpuslaw.us/code/8f5c0c43-d068-4d3c-b698-a0f6d51d416e

Sec. 10-3. Amendments.

The NFPA 101: Life Safety Code adopted by section 10-1 is added to, amended, modified and deleted in the following respects: (a) The following provisions shall be added to the Life Safety Code as un-numbered sections, and shall modify or replace any provisions of the Life Safety Code to the contrary: (1) In addition to the circumstances under which a fire watch may otherwise be required or allowed by the Life Safety Code, in the case of structures posing significant life safety risks that might result in the displacement of person(s), a fire watch, with specifications and criteria to be set by the authority having jurisdiction, may be required if said watch is approved by the authority having jurisdiction, in consultation with the City Manager and Corporation Counsel. (2) Notwithstanding any provisions to the contrary, Carbon Monoxide (CO) alarms and/or detection shall be subject to the following requirements: a. The following shall be protected throughout with CO alarms and/or detectors: i. Existing residential occupancies; and ii. All new occupancies, other than industrial occupancies and storage occupancies. b. CO alarms and/or detection shall be installed in accordance with NFPA 720, Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment, 2015 edition, except that: i. All new construction must have CO alarms and/or detectors hardwired; ii. All new CO alarm and/or detector installations, with the exception of new installations in one- or two-family dwellings, must be hardwired; and iii. The authority having jurisdiction may approve new, alternative CO alarm and/or detector technology as it becomes available, so long as it provides the same amount of protection as required by this Article. (3) New decks or balconies with access from a common space shall be subject to the following requirements: a. They shall be reviewed as a new assembly occupancy; and b. An alarm notification device shall be installed at the balcony or deck level for occupant notification. The device shall operate upon activation of the fire suppression and/or detection system(s) inside the building. (4) Notwithstanding any provisions to the contrary, smoke alarms and/or detection shall be subject to the following additional requirements: a. All smoke alarms and/or detection in new construction or major renovations shall be hardwired with battery backup, shall be interconnected, and shall use photoelectric technology. b. All smoke alarms and/or detection in new installations, except in existing one- and two-family dwellings shall be hardwired with battery backup and shall use photoelectric technology. c. All smoke alarms and/or detection in new installations in existing one- and two-family dwellings shall either meet the requirements for new installations above, or shall be 10-year sealed lithium battery alarms using photoelectric technology. d. The authority having jurisdiction may approve new, alternative smoke alarm and/or detection technology as it becomes available, so long as it provides the same amount of protection as required by this Article. (5) Wherever the requirements governing stairs in the Life Safety Code conflict with the Maine Uniform Building and Energy Code adopted pursuant to 10 M.R.S. § 1103 (MUBEC), the provisions in MUBEC shall control. (b) Inspections. The authority having jurisdiction, upon proper identification, shall have the right to enter at any and all reasonable times for the purpose of inspecting in order to determine compliance with the provision of this Life Safety Code into or upon any premises subject to this article. It shall be a violation of this article for any person either to interfere with or to prevent such inspection. (c) Section 3.3.37.8 shall be amended to read as follows: Historic Building: A building designated a Landmark or Contributing Building within a local or National Register historic district, pursuant to Chapter 14, Article IX of the Code. (d) Section 7.2.2.5.5 shall be amended to add the following language: Exit stair path marking shall also be installed for all new high-rise buildings in accordance with 7.2.2.5.5.1 through 7.2.2.5.5.11. (e) Section 9.7.1.1 shall be amended to add the following language: The authority having jurisdiction shall have power to modify the water supply requirements of this section for individual installations where meeting such requirements are impractical, financial reasons not being a consideration, and provided such requirements shall not be less stringent than the minimum water supply requirements for sprinkler systems in the State of Maine. (f) Subsections 12.3.5.3(3) and (4) shall be deleted. (g) Subsections 13.3.5.3(1) and (2) shall be deleted. (h) Subsection 24.3.5.1 shall be amended to add the following language: However, an automatic sprinkler system shall not be required for the construction of an additional dwelling unit in an existing detached one-family dwelling, unless the construction would otherwise trigger the automatic sprinkler requirements of Chapter 43, as amended. (i) Subsection 43.7.2.3 shall be amended to add the following language: However, the construction of a dwelling unit in a detached accessory structure is not required to comply with the automatic sprinkler requirements of Chapter 24, so long as that detached accessory structure was constructed more than five years prior to the addition of the dwelling unit and the construction does not otherwise trigger the automatic sprinkler requirements of Chapter 43, as amended.

(Ord. No. 188-00, § 6, 4-24-00; Ord. No. 214-01/02, Ord. No. 25-10/11, 8-16-10; Ord. No.215-11/12, 7-2-12; Ord. No. 53-13/14, 10-7-13; Ord. 298-14/15, 7-6-2015; Ord. 127-16/17, 2-22-2017) ; Ord. No. 59-19/20. 11-4-2019; Ord. No. 59-19/20. 11-4-2019; Ord. No. 93-20/21, 10-5-2020)

Ask a question about Portland law

Corpus searches the Portland sections it holds and shows the ones that match, with their citations. Free, no sign-in.