§ 10.4 — Waterfront Port Development Zone
Code of Ordinances, City of Portland, Maine (Chapters as revised by the City Clerk, latest revision September 9, 2026 (each chapter carries its own revision date)) · Portland Code of Ordinances, Land Use Code § 10.4
Corpus is an independent public-information project, not the official City of Portland website. Stable reference: corpuslaw.us/code/b922833e-5f3f-4f63-8a11-28227e0c9b20
10.4 WATERFRONT PORT DEVELOPMENT ZONE (WPDZ)
10.4.1 Purpose Transport of goods by water to and from Portland is an important component of both the local and regional economies. As such, the Port of Portland is integral to the City’s economic, cultural and fiscal health. The Waterfront Port Development Zone (WPDZ) aims to support the ongoing success of the Port by regulating the development of land directly connected to the dredged deep-water channel of the Fore River and Portland Harbor. Activities within the WPDZ are primarily limited to those requiring deep water access and contributing to port operations. Non-marine activities may be permitted if they do not adversely affect marine uses. 10.4.2 No adverse impact on marine uses No use shall be permitted in the WPDZ if it will have an adverse impact on future marine development. A proposed development is deemed to have an adverse impact if it will result in any one or more of the following: A. The proposed use will displace an existing water-dependent use. B. The proposed use will reduce existing commercial vessel berthing space. C. The proposed use and any associated structure(s) or site elements including but not limited to access, circulation, parking, dumpsters, exterior storage, or loading facilities, will unreasonably interfere with the activities and operation of existing water-dependent uses or significantly impede access to vessel berthing or other access to the water by water-dependent uses. D. The siting of a proposed use will substantially reduce or inhibit existing public access to marine or tidal waters. 10.4.3 Permitted uses Subject to a determination that the proposed use meets the standards of Subsection 10.4.2, the uses in Table 10-A are permitted (⏺) or conditional (◐) in the Waterfront Port Development Zone. 10.4.4 Conditional use standards Conditional uses shall be permitted in the Waterfront Port Development Zone provided that notwithstanding Section 6.5 or any other provision of this code, the Planning Board shall be substituted for the Board of Appeals as the review authority. In addition to the provisions of Section 6.5, such uses shall: A. Not impede or preclude existing or potential water-dependent development on other lots. B. Allow for adequate access to the water. C. Be compatible with water-dependent and marine uses. D. Operationally support one or more water-dependent use(s), or be located in a building or structure that is physically adaptable or relocatable to make way for future development of water-dependent uses. E. Meet any additional performance and dimensional standards set forth below. 10.4.5 Prohibited uses Uses which are not enumerated in Table 10-A as permitted or conditional uses are prohibited. Those uses that are prohibited shall include, without limitation: A. Residential uses. B. Hotels or motels, or boatels. C. Auditoriums, civic centers, convention centers, or other meeting facilities. D. Restaurants and bars. E. Marinas, including marina associated boat storage facilities. F. Truck terminals. TABLE 10-A: WPDZ PERMITTED AND CONDITIONAL USES Marine | Marine repair services and machine shops | ⏺ Marine | Tugboat, fireboat, pilot boat, and similar services | ⏺ Marine | Harbor and marine supplies and services and ship supply, such as fueling and bunkering of vessels | ⏺ Marine | Shipbuilding and facilities for construction, maintenance, and repair of vessels | ⏺/◐1 Marine | Marine cargo handling facilities, including docking, loading and related storage | ⏺/◐1 Marine | Boat repair yards | ⏺/◐1 Marine | Facilities for marine construction and salvage | ⏺/◐1 Marine | Facilities for marine pollution control, oil spill cleanup, and servicing of marine sanitation devices | ⏺ Marine | Marine retail and wholesale sales, including yacht brokerage | ◐ Marine | Boat storage facilities | ⏺/◐1 Marine | Seafood processing | ◐ Marine | Seafood packing and packaging | ◐ Marine | Fabrication, storage, and repair of fishing equipment | ◐ Marine | Ice-making services | ◐ Marine | Fabrication of marine-related goods | ◐ Marine | Fish by-products processing, provided that any fish by-product processing facility has a valid rendering facility license under Chapter 12 and the processing of other material wastes or by-products shall not be deemed a lawful accessory use under any other provision of this article. | ◐ Marine | Commercial berthing | ⏺ Industrial | Intermodal transportation facilities principally for vessels with regularly scheduled destination service or for railroad transportation service | ⏺/◐1 Industrial | Marine cargo container and chassis maintenance and repair | ⏺ Industrial | Facilities for combined marine and general construction | ◐1 Industrial | Cold storage facility, warehousing, and storage of goods which are awaiting shipment via cargo carriers | ◐1 Industrial | Low impact industrial uses, including but not limited to bakeries, breweries, bottling, printing and publishing, pharmaceuticals, machine shops, manufacture of products, assembly of electrical components, tool and die shops, and the packaging of food, provided that such uses shall be subject to the performance standards of the I-M zone | ◐ Public | Public uses including pedestrian and bicycle trails | ⏺ Public | Utility substations, including sewage collection and pumping stations, water pumping stations, transfer stations, telephone electronic equipment enclosures and other similar structures, provided that such structures are located more than 100 feet from the water. | ◐ Other | Off-street parking lots, excluding parking structures | ◐ Other | Accessory uses customarily incidental and subordinate to the location, function, and operation of permitted uses2 | ⏺ Other | Minor solar energy systems | ⏺ Other | Minor wind energy systems | ◐ 1 Uses that may be located in buildings that exceed the maximum permitted height. Uses marked ⏺/◐ will be considered permitted uses when occupying buildings with a maximum height equal to or less than the maximum applicable height allowable under the permitted use dimensional standards, and conditional uses when above that height. 2 Food service establishments, including food trucks and other similar retail and service support uses shall only be permitted as accessory uses if each individual use does not exceed 1,000 SF in floor area, and the total of all such uses does not exceed 2,000 SF in floor area; and further provided that such accessory uses provide goods or services that are supportive of the principal use and its clientele. TABLE 10-B: WPDZ DIMENSIONAL REQUIREMENTS | Permitted Use Dimensional Standards | Conditional Use Dimensional Standards Setbacks (min.) | N/A | N/A Lot size (min.) | N/A | 5 acres, limited to 1 building greater than the maximum applicable height allowed under the permitted use dimensional standards. Setback from pier line, wharf, or bulkhead (including any attached aprons)(min.)1 | 5 ft. | 5 ft. Lot coverage (max.) | 50% east of a line projected due south from the centerline intersections of W. Commercial Street and the easterly most Cassidy Point Drive. | Lot coverage (max.) | 100% west of a line projected due south from the centerline intersections of W. Commercial Street and the easterly most Cassidy Point Drive. | Building height (inclusive of roof forms and rooftop appurtenances)(max.)2 | 55 ft. east of a line projected due south from the centerline intersections of West Commercial Street and the easterly most Cassidy Point Drive and west of Casco Bay Bridge. | 60 ft. west of the Casco Bay Bridge7, except as follows: 75 ft. in the area east of a line projected due south from the centerline intersections of W. Commercial Street and the easterly most Cassidy Point Drive and west of Casco Bay Bridge, on lots 5 contiguous acres or larger. 4 130 ft. for bulk storage3 facilities west of the projection of the westerly most Cassidy Point Drive segment. Building height (inclusive of roof forms and rooftop appurtenances)(max.)2 | 60 ft. west of a line projected due south from the centerline intersections of West Commercial Street and the easterly most Cassidy Point Drive. | 60 ft. west of the Casco Bay Bridge7, except as follows: 75 ft. in the area east of a line projected due south from the centerline intersections of W. Commercial Street and the easterly most Cassidy Point Drive and west of Casco Bay Bridge, on lots 5 contiguous acres or larger. 4 130 ft. for bulk storage3 facilities west of the projection of the westerly most Cassidy Point Drive segment. Building height (inclusive of roof forms and rooftop appurtenances)(max.)2 | In no case may any heights exceed 50ft within 100ft of W. Commercial Street and all area of the WPDZ east of the Casco Bay Bridge. 5 | Building length (max.)6 | 450 ft. | 450 ft. Building length (max.)6 | 450 ft. | 300 ft. within 100ft of W. Commercial Street and all area of the WPDZ east of the Casco Bay Bridge. Building length (max.)6 | 300 ft. within 100 ft. of W. Commercial Street and all areas of the WPDZ east of the Casco Bay Bridge. | 300 ft. for buildings or portions of buildings exceeding the maximum applicable height allowed under the permitted use dimensional standards. 1 The setback area may be used for activities related to the principal uses in the structure, but shall not be used for off-street parking. 2 Buildings and/or structures shall be limited to an absolute height measured from average grade with no portion of the structural roof system or roof top appurtenances exceeding the limits set forth under Table 10-B with the exception of moveable elements or connection devices as listed under Subsection 10.4.7 3 Bulk storage dedicated to materials delivered or awaiting transportation to a site by waterborne transportation. 4 A projection of the street centerline shall consist of an extension of the centerline to the water side boundary of the WPDZ. 5 Height limitations east of the Casco Bay Bridge are intended to protect vistas of the harbor from public open space. 6 As measured by a line parallel with the southern edge of the West Commercial Street right-of-way. 7 Only those conditional uses so designated in Note 1 of the Waterfront Port Development Zone Use Table 10-A may be located in buildings taller than 60 ft. 10.4.6 Dimensional requirements In addition to the generally applicable provisions of Article 7 of this Land Use Code, lots in the Waterfront Port Development Zone shall be subject to the requirements of Table 10-B. 10.4.7 Additional bulk, height, and location standards. Moveable elements or connection devices may exceed the maximum height limits set forth in Table 10-B, subject to the following: A. Moveable elements such as cranes and gantries, and connection devices such as conveyors or bridges shall not be subject to the space and bulk requirements, but shall be subject to a determination by the Federal Aviation Administration that the location of such equipment will not create a hazard to navigation. B. The applicant shall provide a determination from the Federal Aviation Administration that structures and equipment will not exceed the applicable height guidelines for the runway approach and will not create a hazard to navigable airspace. Such a determination shall be accepted as conclusive evidence that the proposed development will not create a hazard. C. For each lot, at least one view corridor of at least 90 feet in width shall be left unbuilt to preserve a clear line of sight between West Commercial Street and the water. 10.4.8 Performance standards Proposals in the Waterfront Port Development Zone that qualify for site plan review shall submit, in addition to site plan submission requirements (if applicable), an impact mitigation narrative summarizing how the project meets the applicable performance standards. All uses in the Waterfront Port Development Zone shall comply with the following standards: A. Outdoor storage of materials. Outdoor storage of commodities and materials accessory to normal conduct of business, except pilings and/or cranes, shall be permitted to a maximum height of 45 feet, and such materials shall be entirely contained, including runoff contaminants and residual material, within a designated area within the lot boundaries. B. Noise. 1. The level of sound, measured by a sound level meter with frequency weighting network (manufactured according to standards prescribed by the American National Standards Institute, Inc.), inherently and recurrently generated within the Waterfront Port Development Zone between the hours of 7:00 p.m. and 7:00 a.m. from industrial facilities or operation commenced on or after July 1, 1988, shall not exceed 55 decibels on the A scale at or within the boundaries of any residential zone, except for sound from construction activities, sound from traffic on public streets, sound from temporary activities such as festivals, and sound created as a result of, or relating to, an emergency, including sound from emergency warning signal devices. 2. In measuring sound levels under this subsection, sounds with a continuous duration of less than 60 seconds shall be measured by the maximum reading on a sound level meter set to the A weighted scale and the fast meter response (L maxfast). Sounds with a continuous duration of 60 seconds or more shall be measured on the basis of the energy average sound level over a period of 60 seconds (LEQ1). 3. In addition to the sound level standards otherwise established, facilities or operations established or built in the Waterfront Port Development Zone on or after July 1, 1988, shall employ best practicable sound abatement techniques to prevent tonal sounds and impulse sounds or, if such tonal and impulse sounds cannot be prevented, to minimize the impact of such sounds in residential zones. Tonal sound is defined as a sound wave usually perceived as a hum or which because its instantaneous sound pressure varies essentially as a simple sinusoidal function of time. Impulse sounds are defined as sound events characterized by brief excursions of sound pressure, each with a duration of less than one second. C. Vibration. Vibration inherently and recurrently generated shall be imperceptible without instruments at lot boundaries. This shall not apply to vibration resulting from activities aboard a vessel or from railroad vehicle activities, or from activities on a pile supported pier. D. Federal and state environmental regulations. All uses shall comply with federal and state environmental statutes and regulations regarding emissions into the air, except where provisions of this Land Use Code are more stringent. E. Discharges into harbor areas. No discharge into harbor water areas shall be permitted, unless permitted by the Maine Department of Environmental Protection under a waste discharge license and as approved by the Department of Public Works in accordance with Chapter 24, Article III of the City of Portland Code of Ordinances. All private sewage disposal or private wastewater treatment facilities shall comply with the provisions of Chapter 24, Article II of the City of Portland Code of Ordinances and federal and state environmental statutes and regulations regarding wastewater discharges. F. Storage of vehicles. Storage of any unregistered automotive vehicle on the premises for more than 60 days shall not be permitted. G. Landfill of docking and berthing areas. Landfill of docking and berthing areas shall be governed by 38 M.R.S. § 471 through 478, and permitted only if the landfill does not reduce the amount of linear berthing areas or space, or berthing capacity. If approved, construction shall be undertaken using methods approved by the Department of Public Works and shall be accomplished in accordance with the provisions of this Land Use Code and in a manner so as to ensure that a stable and impermeable wall of acceptable materials will completely contain the fill material and will not permit any fill material to leach into docking areas or navigable waters. H. Off-street parking. Off-street parking and loadingshall be exempt from the standards of Article 18. I. Shoreland and Floodplain Management regulations. Any lot or portion of a lot located in a Shoreland Overlay Zone as identified on the City zoning map or in a flood hazard area shall be subject to the requirements of Articles 11 and 12. J. Lighting. All lighting on the site shall be shielded such that direct light sources shall not unreasonably interfere with vessels transiting the harbor nor have an unreasonable adverse impact on adjacent residential zones. K. Signs. Signs shall be permitted as set forth in Article 19. L. Storage of pollutants and oily wastes. On-premises storage of pollutants and oily wastes shall not be permitted for more than 45 days. M. Compatibility of non-marine uses with marine uses. Non-marine uses, structures and activities, including but not limited to access, circulation, parking, dumpsters, exterior storage and loading facilities or other structures shall neither unreasonably interfere with the existence or operation of marine uses nor significantly impede access to vessel berthing or other access to the water by existing or potential marine uses.
Ask a question about Portland law
Corpus searches the Portland sections it holds and shows the ones that match, with their citations. Free, no sign-in.
