For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 13.6 — Site Plan Review Standards

Code of Ordinances, City of Portland, Maine (Chapters as revised by the City Clerk, latest revision September 9, 2026 (each chapter carries its own revision date)) · Portland Code of Ordinances, Land Use Code § 13.6

Corpus is an independent public-information project, not the official City of Portland website. Stable reference: corpuslaw.us/code/ed8d79a4-a800-4f89-8c0f-2611f5490fc5

13.6 SITE PLAN REVIEW STANDARDS

The reviewing authority shall not approve a site plan application unless the development proposal meets applicable standards of the City of Portland Technical Manual, the City of Portland Design Manual, and the standards below. 13.6.1 Transportation standards A. Impact on surrounding street systems. The provisions for vehicular loading and unloading, parking, and vehicular and pedestrian circulation on the site and onto adjacent public streets and ways and the incremental volume of vehicular, bicycle, pedestrian, and transit traffic will not: 1. Create or aggravate any significant hazard to safety on the surrounding street network. 2. Substantially increase congestion on any street without mitigation proportionate to the level of impact. B. Access and circulation 1. In general a. All development subject to this article shall provide safe and reasonable access and internal circulation for all users of the site and shall comply with the transportation systems and street design standards of the Technical Manual. b. Shared circulation, parking, and transportation infrastructure shall be provided to the extent practicable, with utilization of joint curb cuts, walkways, service alleys, bus pull-out areas, and related infrastructure shared with abutting lots and roadways. Easements for access for abutting properties and shared internal access points at property lines shall be provided where possible to facilitate present or future sharing of access and infrastructure. c. Continuous internal walkways shall be provided between existing or planned public sidewalks adjacent to the site, transit stops and street crossings, and building entrances on the site. d. Where the site abuts or includes an existing or planned publicly accessible trail, a connection to or integration of such trail shall be provided to the extent practicable, including rights of public access. e. Points of access and egress shall be located to avoid conflicts with turning movements and traffic flows. 2. Curb and sidewalks a. All development shall provide curb and sidewalks along all frontages, installed to specifications as described in the transportation systems and street design standards of the Technical Manual. b. Where sidewalks already exist but are in substandard condition, they shall be repaired or replaced in conformance with Chapter 25 of the City of Portland Code of Ordinances and the transportation systems and street design standards of the Technical Manual c. An applicant may request a waiver from sidewalk installation requirements if they meet two or more applicable waiver criteria as listed below: i. There is no reasonable expectation for pedestrian usage coming from, going to, and traversing the site. ii. There is no sidewalk in existence or expected within 1000 feet and the construction of sidewalks does not contribute to the development of pedestrian-oriented infrastructure. iii. A safe alternative walking route is reasonably available, for example, by way of a sidewalk on the other side of the street that is lightly traveled. iv. The reconstruction of the street is specifically identified and approved in the first or second year of the current Capital Improvement Program (CIP) or has been funded through an earlier CIP or through other sources. v. The street has been constructed or reconstructed without sidewalks within the last 24 months. vi. Strict adherence to the sidewalk requirement would result in the loss of significant site features related to landscaping or topography that are deemed to be of a greater public value. d. An applicant may request a waiver from curb installation requirements if they meet two or more applicable waiver criteria as listed below: i. The cost to construct the curbing, including any applicable street opening fees, is in excess of 5% of the overall project cost. ii. The reconstruction of the street is specifically identified and approved in the first or second year of the current CIP or has been funded through an earlier CIP or through other sources. iii. The street has been rehabilitated without curbing in the last 60 months and the proposed use and design of the site does not necessitate the installation of curbing. iv. Strict adherence to the curb requirement would result in the loss of significant site features related to landscaping or topography that are deemed to be of a greater public value. v. Runoff from the development site or within the street does not require curbing for stormwater management. C. Public transit access 1. All residential development consisting of 20 or more dwelling units and all commercial and institutional developments of at least 20,000 square feet gross floor area shall provide a transit shelter adjacent to or within the public right-of-way along its frontage, or at a nearby high-volume transit stop without a transit shelter, when the following criteria are met: a. The development is proposed along an existing public transit route on a principal or minor arterial roadway, as shown in the Federal Street Classification Map. b. The nearest existing transit shelter on the route is more than ¼ mile from the site, measured along rights-of-way. 2. Transit facilities shall be connected to the public sidewalk system. 3. All or some of this standard may be waived if the review authority determines that the development is not anticipated to generate public transit usage due to particular characteristics of the development or proposed use. D. Parking 1. Vehicular parking a. Developments shall comply with the parking standards of Article 18. b. Where provided, parking spaces and aisles shall not be located in front and corner side yards, unless the applicant can demonstrate that site constraints preclude the location of parking elsewhere on the site. c. Where provided, parking spaces and aisles shall meet applicable dimensional standards as detailed in the transportation systems and street design standards of the Technical Manual. 2. Bicycle parking a. All development shall provide secure bicycle parking in accordance with the parking requirements of Article 18 and the transportation systems and street design standards of the Technical Manual. b. The review authority may reduce the required number of bicycle parking spaces if it is determined, based on evidence submitted by the applicant, that the proposed development is expected to generate reduced demand for bicycle parking due to particular site characteristics or proposed uses. 3. Snow storage a. All developments shall include areas for snow storage or provide an acceptable snow removal plan. b. Snow storage areas may not encroach on adjacent properties, public ways, and pedestrian walkways, and shall not be located where they would adversely impact the functionality of stormwater management systems. Landscaping in designated snow storage areas shall be such that it can withstand the snow pile. 4. Electric Vehicle (EV) charging. All development shall meet applicable EV standards as provided in Section 1 of the Technical Manual. E. Transportation Demand Management (TDM) 1. The following types of development shall design and implement a Transportation Demand Management (TDM) plan: a. All commercial, institutional, or mixed-use developments of 50,000 square feet or more in total floor area. b. All commercial or institutional uses designed to accommodate 100 or more employees or, for educational institutions, 100 or more students. 2. The TDM Plan shall comply with the standards for transportation studies and plans as contained in the Technical Manual. 13.6.2 Environmental quality standards A. Preservation of significant natural features 1. All development shall preserve and protect significant natural features by incorporating the principles of Low-Impact Development (LID) in accordance with the LID standards of the Technical Manual. 2. Where complete preservation of significant natural features substantially compromises development of the site as otherwise permitted by zoning, the review authority may reduce the requirement in accordance with the LID standards of the Technical Manual provided that the applicant implements preservation measures to the extent practicable and demonstrates compliance with applicable state and federal regulations. 3. The site plan shall include adequate measures to protect significant natural features to be preserved from construction impacts, in accordance with the LID standards of the Technical Manual. B. Site landscaping and buffers 1. On-site landscaping. a. All development subject to this article shall provide a minimum of one shade tree consisting of species identified on the City of Portland Recommended Tree list or six plantings, defined as one shrub, one ornamental grass, and/or three perennials, per 5,000 square feet of lot area in accordance with the landscaping standards of the Technical Manual. b. Existing vegetation to be preserved on the site may be counted towards this requirement as described in the landscaping and landscape preservation standards of the Technical Manual. c. Where site constraints prevent the planting of required shade trees or plantings at the development site, the reviewing authority may approve an alternative as described in the landscaping standards of the Technical Manual. 2. Buffers and screening a. Loading and servicing areas, trash and recycling areas, storage areas, and roof- and ground-mounted utility structures, except for renewable energy systems, shall be screened from view from public sidewalks, streets and adjacent properties by dense evergreen and deciduous landscaping, fencing, architectural screening products, masonry walls, building walls, or a combination thereof. b. Where immediately visible from the right-of-way, surface parking areas shall be screened with dense evergreen and deciduous landscaping, fencing, or masonry wall in accordance with the landscaping standards of the Technical Manual. c. For nonresidential development abutting a residential zone, an evergreen, densely landscaped buffer of not less than 10 feet in depth and six feet tall is required along the side abutting the residential zone. In cases where architectural fencing is used, the depth of the landscaped buffer may be reduced, so long as the fencing is at least six feet in height and a mix of evergreen and deciduous trees spaced no further than 20 feet apart is planted abutting the residential zone. d. All residential development shall provide and/or preserve evergreen vegetated buffers where necessary to buffer the development from detrimental impacts of existing surrounding development. 3. Parking and vehicle display lot landscaping a. Developments with more than five parking spaces shall include at least one tree for every 750 square feet of uncovered asphalt parking area (including drive aisles), planted in landscaped islands to screen, shade, and break up parking. Trees and shrubs in parking lots may be in informal groups, straight rows, or concentrated in clusters as described in the landscaping standards of the Technical Manual. b. Landscaped islands shall be distributed so that uninterrupted pavement does not exceed forty parking spaces. c. Where site constraints prevent implementation of all or a portion of required parking lot landscaping, as determined by the review authority, the reviewing authority may approve an alternative as described in the landscaping standards of the Technical Manual. 4. Non-vehicular hardscape. All uncovered paving for non-vehicular use, including pathways and patios, must either have a minimum Solar Reflective Index (SRI) of 33 initially and 28 once aged three years or include one tree for every 750 square feet of asphalt paving. 5. Street trees a. All development shall include one street tree per 25-35 linear feet of frontage along a city right-of-way or private roadway as specified in the landscaping standards of the Technical Manual. The provision of measures to enhance tree survival (such as raised planters, irrigation, and structural soils as recommended by the City Arborist) shall be required. b. Where the applicant can demonstrate that site constraints prevent the planting of required street trees in the city right-of-way, the review authority may permit an alternative subject to the landscaping standards of the Technical Manual. c. Where the proposed development includes the removal of an existing street tree determined by the City Arborist to be a heritage or feature mature tree, the applicant shall be required to contribute to the Tree Fund at the designated rate in the Technical Manual so that the total replacement cost is significantly higher than planting a new street tree/contributing for a new street tree. C. Water quality, stormwater management, and erosion control 1. All development shall be designed to minimize total area of impervious surface on the site and both the volume and rate of runoff from the lot. Provisions for stormwater management shall demonstrate the following: a. Any stormwater draining onto or across the lot in its pre-improvement state will not be impeded or re-directed so as to create ponding on, or flooding of, adjacent lots. b. Any increase in volume or rate of stormwater draining from the lot onto an adjacent lot or City property following the improvement can be handled on the adjacent lot or City property without creating ponding, flooding or other drainage problems and that the owner of the lot being improved has the legal right to increase the flow of stormwater onto the adjacent lot or City property. c. Any increase in volume or rate of stormwater draining from the lot into the City’s storm sewer system can be accommodated in the system without creating downstream problems or exceeding the capacity of the storm sewer system. 2. All development shall comply with the stormwater management standards of the Technical Manual. 3. Development shall not pose a risk of groundwater contamination either during or post-construction, as described in the stormwater management and water supply standards of the Technical Manual. 4. Applicants shall demonstrate that subsurface and/or any adjacent slope conditions are suitable to support the development, and where determined necessary, shall prepare a geotechnical study to demonstrate that the development as designed will not adversely impact the development site or any abutting property. Soil surveys and/or geotechnical studies shall be prepared in accordance with the requirements of the Technical Manual. 13.6.3 Public infrastructure and community safety standards A. Consistency with City master plans 1. All developments shall be designed so as to be consistent with City Council-approved master plans and facilities plans and with off-premises infrastructure. 2. The site plan shall include suitable easements, rights, and improvements to connect or continue off-premises public infrastructure as may be required by the review authority. B. Public safety and fire prevention 1. All development shall incorporate the following public safety principles for Crime Prevention through Environmental Design (CPTED) into site design to enhance the security of public and private spaces and to reduce the potential for crime: a. Natural surveillance that promotes visibility of public spaces and areas. b. Access control that promotes authorized and/or appropriate access to the site. c. Territorial reinforcement that promotes a sense of ownership and responsibility through environmental design. 2. All developments shall be designed to provide adequate emergency vehicle access to the site and comply with the Public Safety standards of the Technical Manual. C. Public utilities 1. The development shall not overburden sanitary sewers and storm drains, water lines or supply, or other public infrastructure and utilities. Development shall provide adequate utility infrastructure on-site and in connection to surrounding locations and facilities. 2. Electrical service shall be underground unless otherwise specified for industrial uses, or if it is determined to be unfeasible due to extreme cost, the need to retrofit properties not owned by the applicant, or complexity of revising existing overhead facilities. 3. All sanitary sewer lines, storm drains, water lines, and other utilities proposed as part of the development shall be designed to conform with the sanitary sewer and storm drain and water supply standards of the Technical Manual. 4. All development within 200 feet of a public sanitary collection and treatment system shall connect sanitary sewer lines into the nearest available public sewer. If a public sanitary collection and treatment system is not available, a private wastewater system may be used according to the requirements of Chapter 24 of the City Code and the sanitary sewer and storm drain standards of the Technical Manual. 5. All residential development of 20 units or more, commercial development, and industrial development shall provide for the temporary storage and timely removal of all trash and recyclable materials including, at a minimum, paper, corrugated cardboard, plastics, and metals. Storage containers for recyclable materials shall be separated from trash containers. All exterior storage of trash and recyclables shall be screened from view from public sidewalks, streets, and adjacent properties. 13.6.4 Site design standards A. Massing, ventilation, wind, and heat impact 1. The bulk, location, or height of proposed buildings and structures shall not result in health or safety problems from a reduction in ventilation to abutting structures or changes to the existing wind climate that would result in unsafe wind conditions for users of the site and/or adjacent public spaces. 2. Development shall locate all HVAC venting mechanisms to direct exhaust away from public spaces and residential properties directly adjacent to the site. 3. In proposed buildings or additions with an aggregate roof area greater than 2,000 square feet, measured horizontally, and, for residential projects, greater than nine residential units, a minimum of 75% of the roof area must meet the following “cool roof” Solar Reflective Index (SRI) standards: a. Roofs with a slope less than 2:12: SRI of 82+ (initial)/64+ (3-year aged) b. Roofs with a slope greater than 2:12: SRI of 25+ (initial)/25+ (3-year aged) Roof areas covered by shade structures with an SRI of 39+, including photovoltaic panels that shade the roof, are considered exempt from roof area calculations for the purposes of this standard. B. Shadow. All development over 65 feet in height shall be designed to avoid and/or mitigate the adverse impacts of shadows cast by new structures or building additions from falling on publicly accessible open space in accordance with the shadow standards of the Technical Manual. C. Snow and ice loading. All development shall be designed to prevent significant amounts of accumulated snow and ice from loading or falling onto adjacent properties or public ways. D. View corridors. The massing, location, and height of development shall not substantially obstruct public view corridors identified in the City of Portland Design Manual. E. Historic resources 1. When a development affects a designated landmark or lies within a designated historic district or historic landscape district, such development shall be required to obtain historic preservation approval under Article 16. 2. All development shall document and protect state or local archaeological resources known to exist or discovered on the site. a. Protection may include leaving archaeological resources untouched beneath a new development through adaptation of foundation design or architectural layout. b. Where the applicant can demonstrate that complete protection is not feasible, the applicant shall excavate and document archeological resources. Such measures shall be conducted in consultation with the City’s historic preservation program and Maine Historic Preservation Commission. For resources of state significance, excavation and documentation shall be conducted by a qualified professional, in coordination with Maine Historic Preservation Commission. Local archeological resources may or may not be recognized by the Maine Historic Preservation Commission as significant and shall include the following: i. Original seawall structure located landward of Commercial Street. ii. Inactive historic family cemetery plots. iii. Historic railroad beds including but not limited to the Portland-Lewiston interurban railroad. iv. Original structure and/or landforms associated with the Cumberland and Oxford Canal. v. Buried portions of colonial and post-colonial period structures or built features located on the Portland Peninsula predating the Great Fire of 1866. vi. Pre-colonial occupation sites identified by shell middens or other evidence. vii. Sites listed or eligible for listing on the National Register of Historic Places. c. In order to preserve archeological resources, the review authority may waive standards listed in the City of Portland Technical Manual where necessary if it is determined that such a waiver would not jeopardize the health, safety, or welfare of the development’s occupants, the public, or the natural environment. F. Exterior lighting 1. Site lighting a. All exterior site lighting shall be full cutoff with no light emitted above the horizontal plane or spilled onto adjacent properties. Illumination levels shall be adequate but not excessive for the safety, comfort, and convenience of occupants and users of the site, and shall conform to the lighting standards of the Technical Manual. b. Where light from a proposed development may adversely impact adjacent residential properties, exterior lighting shall employ building-side shielding. 2. Architectural and specialty lighting. a. Architectural and specialty lighting of such features as architectural details, monuments, public art, or other site features shall be designed to illuminate specific details or attributes only and shall meet the lighting standards of the Technical Manual. b. Up-lighting by any method is prohibited except for public buildings and parklands; clock towers and steeples; landscape features; designated historic landmarks; flags of state, federal, or national jurisdictions; and public art. Such light fixtures, brackets, conduits, and all other components shall be designed by a lighting professional and shall be scaled and placed to minimize their visibility and installed in accordance with the lighting standards of the Technical Manual. 3. Street lighting. All development shall provide municipal street lighting adequate for the safety and comfort of pedestrians, bicyclists, and motorists and, where applicable, conforming to specific lighting district requirements as specified in the street lighting standards of the Technical Manual. G. Noise and vibration. All heating, ventilation and air conditioning equipment (HVAC), air handling units (AHU), emergency generators, and similar equipment shall meet applicable state and federal emissions requirements and shall be located to the interior of the site, away from abutting properties. H. Signage and wayfinding 1. On-site directional traffic signage may be provided to enable users to safely and easily navigate into, around and out of the site. 2. Signage shall not adversely affect visibility at intersections on or off the site. I. Design standards 1. Development of certain types and/or proposed in certain zones, as specified in the City of Portland Design Manual, shall meet the design standards of the Design Manual in order to ensure that building and site design contribute to and enhance the goals and policies for specific zones within the city. The City of Portland Design Manual is incorporated by reference as part of this Land Use Code. 2. If the development is located in a historic district or associated with a historic landmark, the standards of Article 16 shall supersede.

Ask a question about Portland law

Corpus searches the Portland sections it holds and shows the ones that match, with their citations. Free, no sign-in.