For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 19.6 — General Requirements for all Signs

Code of Ordinances, City of Portland, Maine (Chapters as revised by the City Clerk, latest revision September 9, 2026 (each chapter carries its own revision date)) · Portland Code of Ordinances, Land Use Code § 19.6

Corpus is an independent public-information project, not the official City of Portland website. Stable reference: corpuslaw.us/code/fb62c856-2fa9-4e30-9f31-e9dc03c2c528

19.6 GENERAL REQUIREMENTS FOR ALL SIGNS

19.6.1 Sign measurement Sign area and height shall be measured as described in Tables 19-C and 19-D. 19.6.2 Computation of the number of signs When determining the number of signs, a single sign shall be considered either enclosed within a single frame or composed of modular parts with identical frame elements designed to be joined together to form a single composite sign. 19.6.3 Sign illumination A. Sign illumination by sign district 1. Table 19-E identifies the type of illumination permitted (●) or not permitted ( ) by sign district. All allowed permanent signs may also be non-illuminated. All permanent signs for single-family residences or duplexes and all temporary signs must be non-illuminated. 2. The illumination level of a sign must be reduced if the Building Authority determines the light output to be excessive. The Building Authority shall use the following criteria to determine if the illumination is excessive: a. The amount of illumination is substantially greater than the illumination level of other nearby signs. b. The sign’s illumination interferes with the visibility of other signs or with the perception of objects or buildings in the vicinity of the sign. c. It directs glare toward streets or motorists. d. It adversely impacts nearby residents or neighborhoods. e. The illumination reduces the night time readability of the sign. B. Internal illumination. To minimize glare, internally-illuminated signs must either be constructed with an opaque background and translucent text and symbols, or with a colored background. Backgrounds must not be white, off-white, light gray, cream, or yellow. TABLE 19-C: SIGN AREA MEASUREMENT Signs on background panel | Sign copy mounted, affixed, or painted on a background panel or surface distinctively painted, textured, or constructed as a background for the sign copy, is measured as that area contained within the sum of the smallest rectangle(s) that will enclose both the sign copy and the background. Signs as individual letters | Sign copy mounted as individual letters or graphics against a building surface that has not been painted, textured, or otherwise altered to provide a distinctive background for the sign copy, is measured as a sum of the smallest rectangle(s) that will enclose each word and each graphic in the sign. Signs on illuminated surface | Sign copy mounted, affixed, or painted on an illuminated surface or illuminated element of a building or structure, is measured as the entire illuminated surface or illuminated element, which contains sign copy. Such elements may include lit canopy fascia signs, and/or interior lit awnings. [image omitted; see the official code] TABLE 19-C (CONT.): SIGN AREA MEASUREMENT Irregular-shaped signs | Sign area for irregular shaped signs is determined by dividing the sign into squares, rectangles, triangles, circles, arcs, or other shapes the area of which is easily calculated. Multi-face signs | For two-face signs, if the interior angle between the two sign faces is 45 degrees or less and the sign faces are less than 42 inches apart, the sign area is determined by the measurement of one sign face only. If the angle between the two sign faces is greater than 45 degrees, the sign area is the sum of the areas of the two sign faces. Multi-face signs | For three- or four-face signs, the sign area is 50 percent of the sum of the areas of all sign faces. Spherical, free-form, or sculptural signs | Spherical, free-form, or sculptural signs are measured as 50% of the sum of the areas of the four vertical sides of the smallest four-sided polyhedron that will encompass the sign structure. Signs with greater than four polyhedron faces are prohibited. Note: Numerals and letters used to identify an address are not included in the determination of sign area. [image omitted; see the official code] [image omitted; see the official code] TABLE 19-D: SIGN HEIGHT MEASUREMENT Building-mounted signs | The height of signs mounted on a building is the vertical distance measured from the base of the wall on which the sign is located to the top of the sign or sign structure. Freestanding signs | Sign height is measured as the vertical distance from the finished grade at the base of a sign to the top of the sign exclusive of any filling, berming, mounding, or landscaping solely for the purpose of locating the sign and excluding decorative embellishments as permitted in Section 19.7. [image omitted; see the official code] [image omitted; see the official code] TABLE 19-E: SIGN ILLUMINATION BY SIGN DISTRICT Sign District Name | Type of Illumination | | | | | | | External | Direct | Internal (Cabinet or Halo Sign) | Internal (Individual Letters /Logo) | Neon | Single or Two-Color LED | Electronic Message Signs Residential Sign District | -- 1 | | | -- 1 | | | -- 1 Small Mixed-Use Sign District | ● | ● 2 | ● 3 | ● | ● | ● | Large Mixed-Use Sign District | ● | ● | ● | ● | ● | ● | ● Downtown Sign District | ● | ● | ● | ● | ● | ● | Industrial and Transportation Sign District | ● | ● | ● | ● | ● | ● | ● 4 Open Space Sign District | ● | | | | | | 1 Allowed for institutional uses only. 2 Only allowed in B-1, B-2b, IS-FBC, and I-B zones. 3 Only allowed in O zone. 4 Only allowed in I-L, I-M, and I-H zones. C. External illumination 1. Externally-illuminated signs must be illuminated only with steady, stationary, fully-shielded light sources directed solely onto the sign without causing glare. 2. The light source for externally-illuminated signs must be arranged and shielded to substantially confine all direct light rays to the sign face and away from streets and adjacent properties as illustrated in Figure 19-A. FIGURE 19-A: EXTERNAL ILLUMINATION [image omitted; see the official code] D. Direct illumination. All direct illumination must be turned off daily at the close of business or 10 p.m., whichever occurs last. E. Neon. Exposed neon sign lighting must be turned off daily at the close of business or 10 p.m., whichever occurs last. F. Single-color or two-color LED signs. 1. Single or two-color LED signs are exempt from the sign area limitations for window signs and building-mounted signs. 2. Single or two-color LED signs must be turned off daily at the close of business or 10 p.m., whichever occurs last. G. Electronic Message Signs 1. One electronic message sign is allowed per lot. 2. Electronic message signs must not flash, blink, flutter, include intermittent or chasing lights, or display video messages (i.e., any illumination or message that is in motion or appears to be in motion). Electronic message signs may display changing messages provided that each message is displayed for no less than 30 seconds. 3. Electronic message signs must be equipped with photocell technology to control and vary the intensity of light output depending on the amount of ambient light that is present to prevent overly bright luminance at night. Automatic controls must limit night luminance to a maximum of 100 nits when the display is set to show maximum brightness in 100 percent full white mode. 4. The applicant shall provide a written certification from the sign manufacturer that the night time luminance has been factory pre-set not to exceed 100 nits as described in (3) above, and that this setting is protected from end-user modification by password-protected software or other method as deemed appropriate by the Building Authority. 5. Electronic message signs must be turned off daily at the close of business or 10 p.m., whichever occurs first. 19.6.4 Changeable sign copy Changeable sign copy must comply with the following standards: A. Maximum area. The maximum area of changeable sign copy shall be limited to 50% of the total sign area, except for marquee signs. This does not apply to any signs required by law. B. Sign design. The changeable sign copy must be an integral part of a permanent building-mounted or freestanding sign. C. Illumination. Changeable sign copy may be non-illuminated or internally-illuminated. 19.6.5 Structure and installation A. Authority. The construction of signs shall be enforced and administered by the Building Authority. All signs and advertising structures must be designed to comply with the provisions of this article and applicable provisions of Chapter 6 of the City of Portland Code of Ordinances and constructed to withstand wind loads, dead loads, and lateral forces. B. Electrical features. Where electrical service is provided to freestanding signs or landscape wall signs, all such electrical service must be placed be underground and concealed. Electrical service to building-mounted signs, including conduit, housings, and wire, must be concealed or, when necessary, painted to match the surface of the structure upon which they are mounted. An electrical permit shall be issued prior to installation of any new signs requiring electrical service. C. Raceway cabinets. Raceway cabinets, as illustrated in Figure 19-B, shall only be used in building-mounted signs when access to the wall behind the sign is not feasible, shall not extend in width and height beyond the area of the sign, and shall match the color of the building to which it is attached. Where a raceway cabinet provides a contrast background to sign copy, the colored area is counted in the total allowable sign area allowed for the site or business. A raceway cabinet is not a cabinet sign. FIGURE 19-B: RACEWAY CABINET EXAMPLES [image omitted; see the official code] D. Materials. All permanent signs allowed by this article must be constructed of durable materials capable of withstanding continuous exposure to the elements and must be permanently attached to the ground, a building, or another structure by direct attachment to a rigid wall, frame, or structure. 19.6.6 Sign maintenance All signs must be maintained by any property owner, lessor, lessee, manager, agent, or other person having lawful possession or control over a building, structure, or parcel of land, in a condition or state of equivalent quality to which was approved or required by the City. All signs together with their supports and appurtenances must be maintained in good structural condition, in compliance with applicable provisions of Chapter 6 of the City of Portland Code of Ordinances, and in conformance with this article. Maintenance of a sign includes periodic cleaning, replacement of flickering, burned out, or broken light bulbs or fixtures, repair or replacement of any faded, peeled, cracked, or otherwise damaged or broken parts of a sign, and any other activity necessary to restore the sign so that it continues to comply with the requirements and contents of the sign permit issued for its installation and provisions of this article.

Ask a question about Portland law

Corpus searches the Portland sections it holds and shows the ones that match, with their citations. Free, no sign-in.