For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 9.1 — India Street Form-Based Zone

Code of Ordinances, City of Portland, Maine (Chapters as revised by the City Clerk, latest revision September 9, 2026 (each chapter carries its own revision date)) · Portland Code of Ordinances, Land Use Code § 9.1

Corpus is an independent public-information project, not the official City of Portland website. Stable reference: corpuslaw.us/code/0a7ab2da-6fab-465c-af15-19433e140ffa

9.1 INDIA STREET FORM-BASED ZONE

9.1.1 Purpose The India Street Form-Based Code is different than traditional zoning, placing the primary emphasis on a building’s physical form and its relationship to the street, and de-emphasizing land use. The intent of the India Street Form-Based Code Zone is to establish a zone that encourages a vibrant, walkable, mixed-use urban district, preserves and values the existing historic neighborhood fabric, and fosters and supports local businesses and residential areas. The goal of the India Street Form-Based Code is the creation and preservation of an active and human-scale public realm and the reinforcement of existing neighborhood character through good streetscape design. The components of the form-based code include the guiding principles, Regulating Plan, subdistricts, general development standards, dimensional requirements, building design standards, diagrams, and definitions. 9.1.2 General guiding principles The general guiding principles set forth here shall be applicable to all subdistricts within the India Street Form-Based Code Zone: A. The street is a coherent space, with consistent building and streetscape character on both sides of the street. This agreement of buildings and streetscape across the street contributes to a clear public space and district identity. B. The street wall is visually well defined. Land should be clearly public or private. Buildings contribute to the vital and safe public space while providing a clear boundary to the private, protected realm. C. Street walls are engaged with the street environment. Buildings are inviting places that interact with and contribute to the street vitality. Inactive edges, vehicle storage, garbage, and mechanical equipment should be kept away from the street. Shared infrastructure, to the extent practicable, including, but not limited to, service alleys, parking areas, stormwater treatment, public transportation facilities, and driveways, shall be utilized. D. Buildings are designed for the urban environment. Buildings must be designed for the urban situation within the subdistrict which often includes mixed-uses. Buildings are positioned near the street and facades are oriented to the street. E. Respect historic character. If a property is within the India Street Historic District, Article 16 is applicable. New construction, building additions, or alterations in the India Street Historic District shall reflect and complement the character-defining features and elements of the existing historic development to which it is visually related. 9.1.3 Applicability A. The requirements set forth in this Section 9.1 shall apply to all new development, primary and accessory structures, including building additions within the India Street Form-Based Code Zone as designated on the India Street Regulating Plan. B. A waiver of the requirements listed below may be granted if it can be demonstrated to the satisfaction of the FIGURE 9-A: IS-FBC REGULATING PLAN [image omitted; see the official code] Planning Authority that the requirements in Subsection 9.1.3(C) below have been met: 1. Building orientation. 2. Blank façade length (max.). 3. Fenestration, ground floor facade area. 4. Building entry frequency, orientation, or elevation. 5. Garage door setback or width. 6. Additional building length – ground floor partition or module requirements. C. A waiver request must meet the following requirements: 1. The intent of the IS-FBC Zone as stated in Subsections 9.1.1 and 9.1.8. 2. Be the least adjustment necessary to satisfy the practical, programmatic, or functional needs of the proposed development. 3. At least one of the following applies: a. The proposed zoning alternative better achieves the zone and subdistrict intent. b. The zone or subdistrict intent will not be met by applying the requirement in this particular circumstance. c. There is a legal or practical necessity or unique conditions. d. Unique site factors make the zoning requirement impractical or cost prohibitive. 9.1.4 Establishment of subdistricts The India Street Form-Based Code Zone as shown on the Regulating Plan is divided into three subdistricts: A. Urban Neighborhood (UN) Subdistrict. B. Urban Transitional (UT) Subdistrict. C. Urban Active (UA) Subdistrict. 9.1.5 Regulating Plan The Regulating Plan shows the location of the zone boundary and subdistricts subject to regulation by the IS-FBC Zone. 9.1.6 General development standards A. Prohibited uses 1. Correctional pre-release facilities. 2. Funeral homes. 3. Drive-through facilities. 4. High‐impact industrial uses. 5. Auto service stations. 6. Truck terminals. 7. Recycling and solid waste disposal services. 8. Storage and parking facilities for Class 1 flammable and combustible liquids (having an aggregate total of more than 100 gallons) but excluding storage that is part of a motorized vehicle or pleasure craft facility. B. Performance standards. All uses permitted within this Article 9 shall conform to the mixed-use and B-2/B-2b zone performance standards established in Section 6.8. Where no zone is specified, the performance standard applies. C. Siting standards 1. Mid-block permeability a. On lots with frontage on two streets roughly parallel to Commercial/Thames Street, for each and every 200 feet in street line length of lot, a full break between structures of at least 20 feet in width shall be provided roughly perpendicular to Commercial/Thames Street and within the middle third of the applicable street frontage. (See Figure 9-F.) b. Is encouraged in any location that connects existing public or private alleys, passages, or streets. c. Any development providing mid-block permeability with public access in the form of a continuous path of travel with a minimum clear width of 10 feet between two streets is eligible for one additional story of up to 12 feet in height under the provisions of Subsection 9.1.6(D). Public access shall be defined through a legal agreement such as an easement or license. d. For locations where mid-block permeability is required, refer to the Regulating Plan. 2. Frontage requirements a. Minimum street frontage: 30 feet b. Building length measurement shall not include porches, decks, or balconies that are appended to the principal structure. c. In the case of a corner lot or lot bounded by at least three streets, maximum building lengths may not be exceeded in order to meet front yard setbacks. d. Additional building length is allowed beyond the maximum building length under the following circumstances and according to Table 9-A: i. Attached buildings: An unlimited number of attached buildings having up to 30 feet of street-facing building length is allowed. A party wall condition is required at least every 30 feet and for the entire height of each building. (See Table 9-A Additional Building Length – Attached Buildings.) ii. Ground floor partitions: Additional building length is permitted with the provision of ground floor partitions where the following conditions are met. (See Table 9-A Additional Building Length – Ground Floor Partitions.): a) Partitions must extend from the facade at least 2/3rds of the building depth. b) Partitions must be architecturally expressed on the building exterior. c) Each module created by partition must have at least one functional, street-facing entry. TABLE 9-A: ADDITIONAL BUILDING LENGTH Subdistrict | Attached Buildings | Ground Floor Partitions | Massing Variation | Structured Parking Exception UN | Unlimited run | Not allowed | Not allowed | Not allowed UT | Unlimited run | 200 ft. max. length; 2 modules | 200 ft. max. length | 200 ft. max. length UA | Unlimited run | 150 ft. max. length; 3 modules | Not allowed | 150 ft. max. length d) Modules created by partition shall be sized to have reasonable function and proportion in relation to overall building length. e) In the UA subdistrict, number of modules are required based on building length. In a building with a length greater than 50 feet but less than 100 feet, at least two modules are required. In a building with a length greater than 100 feet but less than or equal to 150 feet, at least three modules are required. f) Massing Variation: Additional building length is permitted where at least 30% and up to 40% of the total façade building length is set back at least 20 feet. (See Table 9-A Additional Building Length – Massing Variation.) g) Structured Parking Exception: Additional building length for one facade without partition walls is allowed for the use of ground-level structured parking. 3. Setbacks a. Lots with a street frontage of less than 35 feet are exempt from providing side yards but only where required yard is perpendicular to the frontage that is less than 35 feet. b. Where new construction or building additions create a side yard of less than five feet, a maintenance easement is required where a combination of the side yard and easement must be at least five feet. Party wall conditions are exempt from providing a maintenance easement. Corner lots may only apply the side yard reduction to one required side yard. c. Building facades within 10 feet of a corner are exempt from setback requirements in order to allow special corner architectural treatments. d. Subdivision developments consisting of horizontally attached buildings on individual lots are not required to have side yards between buildings where a party wall condition will exist, but shall be required to meet the applicable side setbacks at the external and internal subdivision lot boundaries between buildings that are not attached to each other. 4. Landscaping and screening TABLE 9-B: WALL/FENCE DIMENSIONAL REQUIREMENTS Location | Height | Visual Permeability Within front yard | 6 ft. max. | Required above 2 ft. from sidewalk grade Side or rear yard | 8 ft. max. | n/a a. Surface parking areas shall be screened from view from sidewalks, public rights-of-way, and public open spaces using landscaping, walls, fencing, or a combination thereof. TABLE 9-C: HEIGHT BONUSES Subdistrict | Pre-Bonus Height (max.) | Mid-Block Permeability1 | | Green Roof | Height With Bonus (max.) | Bonus Floor Stepback2 (min.) UN | 45 ft. and 4 stories | n/a | | n/a | 57 ft. up to 5 stories | 15 ft. UT | 65 ft. and 6 stories | 1 story up to 12 ft. | . | 1 story up to 12 ft. | 77 ft. up to 7 stories | 15 ft. UA (Congress Street and Commercial Street only) | 50 ft. and 4 stories | 1 story up to 12 ft. | | 1 story up to 12 ft. | 62 ft. up to 5 stories | 15 ft. 1 Must be publicly accessible in the form of a continuous path with a minimum clear width of 10 feet. 2 Measured from the ground floor building edge facing any public right-of-way. b. Walls and fences shall meet the dimensional requirements in Table 9-B. 5. Building additions. Building additions are exempt from story minimums or maximums in order to match existing building in number of stories. All other subdistrict height standards shall apply including height minimums and maximums in feet. D. Height standards 1. Height bonus applicability. Only one height bonus may be applied per structure. 2. If a frontage faces a UT street, UN street, or allowed UA street according to Table 9-C, then the portion of the building facing that street is eligible for a height bonus. For lots with multiple frontages where a frontage faces an ineligible street, the bonus story must be stepped back at least 35 feet from ineligible street line. (See Subsection 9.1.8(D).) 3. One additional story of up to 12 feet in height is allowed for any development providing a green roof, where: a. At least 50% of the cumulative lot area is pervious. b. At least 50% of the cumulative roof area is a green roof. Green roof area may be applied towards the 50% lot area requirement. Maintenance shall be assured by a maintenance plan and maintenance agreement approved by the Planning Authority. 4. For affordable housing projects in which over 75% of units are low-income or workforce units, maximum heights may be increased by 12 feet. E. Parking standards 1. Parking shall be provided as per Article 18. 2. In the case of a building addition, non-conforming existing surface parking may remain. In the case of new construction, surface parking must be brought into conformance with IS-FBC standards. 9.1.7 Subdistrict dimensional requirements A. Urban Neighborhood (UN) subdistrict The intent of this subdistrict is to maintain and promote a small-scale, less active urban fabric. Buildings may be more private in character and have smaller footprints with building types including, but not limited to, single-family, townhouses, duplexes, triple-deckers, and double-triples. Building frontages may be less transparent and entries may be raised above sidewalk level with frontage types including raised, recessed doorways, porches, and stoops. The streetscape has variable setbacks and landscaping with many buildings within one block and streets tend to be narrow. [image omitted; see the official code] B. Urban Transitional (UT) subdistrict The intent of this subdistrict is to encourage higher density, mixed-use building types that accommodate any use. Building frontages are a mix of activity level, have larger footprints, and the most flexibility of height and scale. Building ground floor spaces tend to accommodate flexible and changing uses with frontage types including doorways, forecourts, arcades, and storefronts. The streetscape may be less active than the UA subdistrict with wide sidewalks, street trees, and setbacks and stepbacks providing relief from large building masses. [image omitted; see the official code] C. Urban Active (UA) subdistrict The intent of this subdistrict is to maintain and promote a moderate-scale, diverse, mixed-use neighborhood with vibrant streets and active ground floor spaces. Buildings are more active and engage the street at the ground level. Building frontages are transparent and entries are at sidewalk level with frontage types including storefronts and recessed doorways. The streetscape has steady street planting, and buildings set close to the street providing a consistent street wall. [image omitted; see the official code] D. Corner conditions For corner lots where two subdistricts intersect at a street corner, the dimensional requirements and building design standards of the “dominant” subdistrict shall apply 35 feet deep into the lot measured from the dominant lot line along its associated street frontage or public ways including required mid-block permeability. Otherwise, dimensional requirements shall be according to the subdistrict onto which the building façade faces. [image omitted; see the official code] FIGURE 9-B: DIMENSIONAL REQUIREMENTS ILLUSTRATED [image omitted; see the official code] FIGURE 9-B (CONT.): DIMENSIONAL REQUIREMENTS ILLUSTRATED [image omitted; see the official code]

Ask a question about Portland law

Corpus searches the Portland sections it holds and shows the ones that match, with their citations. Free, no sign-in.