§ 13-558 — Fugitive dust monitoring

Code of Ordinances of the City of Dearborn, Michigan (2026 S-07: Code and Zoning updated through September 22, 2026) · Dearborn City Code § 13-558

Corpus is an independent public-information project, not the official City of Dearborn website. Stable reference: corpuslaw.us/code/49dd6bc1-be98-4a8a-b17d-92856eac8014

Sec. 13-558. Fugitive dust monitoring.

(a) Unless, pursuant to the variance procedure set forth in this article, the facility owner or operator establishes that the facility’s operations do not and will not result in off-site fugitive dust emissions, or if the facility qualifies as exempt under Sec. 13-545, the department shall require the facility owner or operator to install, operate, and maintain, according to the manufacturer’s specifications, permanent, continuous, federal equivalent method (FEM) real-time PM10 monitors around the perimeter of the facility in accordance with the requirements specified in this section. (b) First year of monitoring; placement of monitors. During the first year of monitoring, at least one monitor shall be placed along each side facing the four cardinal directions (north, south, east, and west) around the facility to monitor for fugitive dust in the ambient air around the facility. (c) Subsequent years of monitoring; placement of monitors. During the second and all subsequent years of monitoring, monitors shall be placed in accordance with the fugitive dust plan based on the data observed in the first year, with monitors located at a minimum of two upwind and two downwind locations and additional monitors as appropriate depending on the size of the facility and other relevant factors, such as variability of wind direction at the site and the proximity of neighborhoods. (d) A data logger shall be attached to the monitors to record readings from the monitors, and the facility owner or operator shall notify the department in writing within 24 hours each time the monitors exceed the reportable action level, and any time monitoring equipment has malfunctioned preventing readings or logging of data. (e) The facility owner or operator shall maintain a log of all maintenance and calibration activities associated with each fugitive dust monitor. (Ord. No. 24-1815, 4-23-24)

Ask a question about Dearborn law

Corpus searches the Dearborn sections it holds and shows the ones that match, with their citations. Free, no sign-in.