Sec. 5-1110. - Appliance operation, oxygen concentration pressure.
The concentration of oxygen in the flue products shall in no case be less than four percent, nor more than ten percent. The rate of flow of the gas shall be adjusted to within plus or minus five percent of the required hourly BTU input rating at the manifold pressure specified by the manufacturer. When the prevailing pressure is less than the manifold pressure specified, the gas rate shall be adjusted to the prevailing pressure. (Ord. No. 81-65, § 11.54, 11-4-81)