For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5-1110 — - Appliance operation, oxygen concentration pressure

Code of Ordinances of the City of Dearborn, Michigan (2026 S-07: Code and Zoning updated through September 22, 2026) · Dearborn City Code § 5-1110

Corpus is an independent public-information project, not the official City of Dearborn website. Stable reference: corpuslaw.us/code/b7f95eee-696a-461f-b455-a66f5079cdff

Sec. 5-1110. - Appliance operation, oxygen concentration pressure.

The concentration of oxygen in the flue products shall in no case be less than four percent, nor more than ten percent. The rate of flow of the gas shall be adjusted to within plus or minus five percent of the required hourly BTU input rating at the manifold pressure specified by the manufacturer. When the prevailing pressure is less than the manifold pressure specified, the gas rate shall be adjusted to the prevailing pressure. (Ord. No. 81-65, § 11.54, 11-4-81)

Ask a question about Dearborn law

Corpus searches the Dearborn sections it holds and shows the ones that match, with their citations. Free, no sign-in.