For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5-313 — - Definitions

Code of Ordinances of the City of Dearborn, Michigan (2026 S-07: Code and Zoning updated through September 22, 2026) · Dearborn City Code § 5-313

Corpus is an independent public-information project, not the official City of Dearborn website. Stable reference: corpuslaw.us/code/5bee09ec-f200-4d75-9b33-f2fab09aaa6e

Sec. 5-313. - Definitions.

The following words, terms and phrases, when used in this article, shall have the meanings ascribed to them in this section, except where the context clearly indicates a different meaning. Aggregate shall mean the total of the horsepower/tonnage or heating surface in a group of equipment. Alteration shall mean a change in the piping structure or construction of boilers, fired pressure vessels, unfired pressure vessels or any equipment coming within the scope of this article. Annual operating permit shall mean the written permission granted by the building and safety department to an owner to operate a power plant for a specified period. Appurtenance shall mean an adjunct or accessory required in connection with boilers, fired pressure vessels, unfired pressure vessels, prime movers or their auxiliaries. For example, the water column, blow-off valves and steam pressure gauge are appurtenances of a boiler. Attending licensed operator shall mean the licensed operator who is designated by the person having control or management of the property, or other person, to operate the equipment. Automatic monitoring shall mean any Underwriters Laboratory approved energy system which operates a mechanical and/or electronic device or system. Auxiliary shall mean any of the various pieces of equipment such as but not limited to: fans, stokers and pumps required in the operation of a boiler, fired pressure vessel or prime mover. Auxiliary room shall mean space enclosed or set apart, in which the auxiliaries incident to a boiler or fire pressure vessel are housed. Banked operation , the banked operation of a boiler or fired pressure vessel shall mean that the fuel supply has been positively cut off so that no fuel shall be introduced into the firing chamber, either automatically or manually; that air supplied in the firing chamber shall be below that used under normal operating conditions and blocked securely so that it cannot be increased toward the normal operating level; that the pressure in the vessel is below the authorized maximum at the time the fired pressure vessel is banked; and that the pressure in the vessel will continue to recede from the authorized pressure. Board shall mean the Board of Safety Engineers in the city as established by this article. Boiler shall mean a pressure vessel containing a liquid and in which vapor is generated or pressure is developed by the application of heat resulting from the conversion of any form of energy. For the purpose of this article, the above shall be the definition of a boiler together with the following: Superheaters, whether integral or separately fired, economizers, all boiler appurtenances, all steam or vapor piping and fittings connecting the boiler drum to superheaters, all piping from the boiler inlet and outlet connections up to and including the stop valve or valves required by the A.S.M.E. Boiler Code, all feed piping and fittings starting with the inlet valve to the economizer or to the boiler drum and all boiler blow-off piping and fittings from the boiler proper, water walls, or economizers, to and including the valve or valves as required by the A.S.M.E. Boiler Code. Boiler classification shall mean boilers classified as follows: (1) High pressure boiler shall mean a fired pressure vessel carrying over 15 psig or, where vapor is not generated, a boiler in which the liquid temperature exceeds 250 degrees Fahrenheit and the liquid pressure exceeds 160 psig. (2) Low pressure boiler shall mean any fired pressure vessel in which the maximum allowable working pressure for steam or other vapor is limited to 15 psig or, where vapor is not generated, a boiler in which the liquid temperature does not exceed 250 degrees Fahrenheit and the liquid pressure does not exceed 160 psig. Boiler horsepower shall mean ten square feet of boiler or fired pressure vessel heating surface. The horsepower of vapor generating pressure vessels of a type not having heating surface exposed to products of combustion may be based on accepted energy units, conversion factors and conduction formulae. Boiler room shall mean a space enclosed or set apart, in which one or more boilers or fired pressure vessels are installed. City shall mean City of Dearborn. Compliance officer shall mean the city employee designated by the director of the building and safety department to enforce this division. Department shall mean the Building and Safety Department. Director shall mean the Director of the Building and Safety Department in the City of Dearborn. Examiner shall mean the examiner of the Building and Safety Department in the City of Dearborn. Engine horsepower shall mean 33,000 foot pounds per minute or the expanding of 42.42 BTUs per minute. He shall be used as a nonsexist term referring to men and women alike. Heating surface shall mean any part of a boiler or fired pressure vessel having liquid or vapor on one side and heat resulting from combustion on the other side which can be determined by the state boiler board of boiler rules and the A.S.M.E. Code. License shall mean a formal permission granted by the department of building and safety permitting an individual person to operate for a specified period specific classes of boilers and other equipment coming within the scope of this article. Licensed operator or engineer shall mean a person holding any one of the licenses issued in accordance with the provisions of this article, authorizing him to operate, or supervise the operation of, specified classes of boilers, and other equipment coming within the scope of this article. Low load shall mean a reduced capacity or idle/banked rated capacity with no more than 50 percent utilization of the maximum rated capacity of either heating or cooling systems. Occupied shall mean periods of time the building is open for business or operational activities. Operation outside of normal business hours shall mean the presence of a licensed operator shall not be required when the premises served by steam boilers or hot water boilers (as for example, nights, weekends and holidays) are closed to normal operations or public usage, provided all of the following requirements are met: (1) The aggregate heating surface of the boiler system does not exceed 1,500 square feet. (2) Steam boilers are equipped with approved safety relief valves set and stamped to relieve at not more than 15 psig, and hot water boilers are equipped with approved safety relief valves set and stamped to relieve at not more than 160 psig. (3) An approved automatic means of feeding water into the boilers is provided. (4) Boilers are equipped with an approved pressure control with a maximum setting not to exceed 90 percent of the setting of the safety relief valves or safety valves, and, in addition, hot water boilers are equipped with an approved temperature control with a maximum setting of 250 degrees Fahrenheit. (5) An approved control requiring manual resetting is installed which will shut off the fuel and air supply in the event of low water. (6) During this period the boiler shall be used only for space heating, indirect hot water supply heating, or the maintaining of temperatures of idle processes. (7) Such methods of operation shall not be put into effect until written permission has been granted by the department. (8) The equipment must have two approved low water cutoffs as required by the city boiler code. Operate shall mean to have control and responsibility for the safe operation of heating and/or cooling systems or equipment. Permit shall mean written permission granted by the department of building and safety a person to install, replace, alter or construct a specified piece of equipment at a specific location. Portable boiler operating permit shall mean a permit to operate boiler used for temporary heating, to process steam, or for heating water for industry-type operations. A portable boiler operating permit may be issued with the approval of the building and safety department for a maximum of six months. Post of duty shall mean the station place or position to be occupied by a person licensed under this article while carrying out his assigned tasks and responsibilities. Power plant shall mean a building or factory including all of the equipment for generating power or for purposes of a heating boiler plant. Premises shall mean a lot, plot or parcel of land, including any structure thereon. Pressure shall mean pounds per square inch (psig). Prime mover shall mean an initial source of motive power, such as an engine or turbine, which receives heat or energy in some other natural form and converts it into mechanical power which is then applied to drive other machinery. Weld shall mean to unite metallic parts by heating, to a plastic or fluid state, and then allowing the metal to flow together with or without the addition of other molten metal. (Ord. No. 85-323, § 1.4, 6-4-85; Ord. No. 95-631, 4-18-95; Ord. No. 98-742, 10-20-98; Ord. No. 99-787, 8-3-99) Cross reference— Definitions and rules of construction generally, § 1-2.

Ask a question about Dearborn law

Corpus searches the Dearborn sections it holds and shows the ones that match, with their citations. Free, no sign-in.