Sec. 5-362. - Automatic and/or monitoring devices; operation during low load conditions.

If a high or low pressure boiler system or refrigeration system is equipped with an automatic and/or monitoring device or system, the presence of a licensed boiler operator shall not be required during low load conditions such as holidays, weekends, and other low load times, provided all of the following requirements have been met: (1) The owner or operator of the building where such device or system is located must have an annual operating permit for the automatic monitoring device. Such permit shall be approved by the director of economic and community development or his designee. The fee for permit shall be as set forth in section 9-68 of this Code. (2) The aggregate heating surface of the boiler system does not exceed 1,000 square feet. (3) All steam boilers and refrigeration systems equipped with such devices or systems must be equipped with approved energy management systems. (4) All steam boilers equipped with such devices or systems must be equipped with approved safety relief valves set and stamped to relieve pressure at not more than 15 psig. All hot water boilers equipped with such devices or systems must be equipped with approved safety relief valves set and stamped to relieve at not more than 160 psig. (5) An approved automatic means of feeding water into the boiler must be provided. (6) Boilers are equipped with a master control which includes an approved pressure control device with a maximum setting not to exceed 85 percent of the setting of the safety relief valves or safety valves. Hot water boilers must be equipped with an approved temperature control device which includes a maximum setting of 240 degrees Fahrenheit. (7) An approved control device or system must be installed which requires manual resetting and will shut-off fuel and air supplies in the event of a low water situation. (8) The boiler room must have two means of ingress and egress and comply with all applicable provisions of the building code. (9) All boiler and chiller systems must have required safety controls. Boilers must have two approved low water cut-off devices of systems with manual reset. Chillers must be equipped with manual rest. (10) All refrigeration systems must have required safety controls approved by the current ASHRAE Mechanical Refrigeration Code or Underwriters Laboratory energy management systems. (11) Such methods of operation shall require the approval of the board and the director of the economic and community development department. The board may grant temporary approval if conditions necessitate approval for one season. (12) The compliance officer or the director may revoke approval if any condition of approval has not been met upon providing written notice to the property owner. Such approval may be revoked if the required renewal fees are not paid or property owner is in violation of any applicable codes or ordinances to the equipment. Furthermore, the compliance officer may enter the premises at any time during normal business hours for the purpose of testing any monitoring or automatic control device in order to ensure code compliance and to ensure the public health, safety, and welfare. (Ord. No. 95-631, 4-18-95; Ord. No. 98-742, 10-20-98; Ord. No. 99-787, 8-3-99; Ord. No. 09-1262, 12-14-09)

Ask a question about Dearborn law

Corpus searches the Dearborn sections it holds and shows the ones that match, with their citations. Free, no sign-in.