Sec. 18-1-44. - Bowling pin reconditioning and refinishing.

(a) Permit. No person shall recondition or finish bowling pins, involving the use, storage, handling or application of flammable liquids or hazardous materials on the premises of a bowling alley, without first having obtained a permit from the Fire Marshal. (b) Application for permit. Upon application for such permit, a set of plans, which shall provide for a room or building for the reconditioning and/or finishing of bowling pins, shall be submitted to the Fire Marshal and to the Buildings, Safety Engineering, and Environmental Department. This room or building shall be constructed as follows: (1) The room shall be separated from the remainder of the building by an unpierced fire wall with a fire resistive rating of four hours, with all entrances and/or exits to or from the room directly from the outside; (2) At least one wall of the pin finishing and/or reconditioning room shall be an exterior wall; (3) Approved explosion venting shall be provided for the pin finishing and/or reconditioning room or building, and shall be in the exterior walls or roof only. The venting area shall be equal to not less than one square foot per 50 cubic feet of room volume and may consist of any one or any combination of the following: where the ceiling of the room constitutes the roof of the building, a ceiling of light noncombustible material designed to relieve at a maximum pressure of 25 pounds per square foot; lightly fastened swinging doors in exterior walls, opening outward; single-strength glass in metal window sash; and lightly fastened roof hatches or lightly fastened noncombustible wall section. In no instance shall explosive facilities be so designed as to create a hazard to adjacent occupancies or passersby; (4) The pin finishing and/or reconditioning room or building shall be completely protected by an approved sprinkler system; (5) The remainder of the room or building shall be constructed to conform to the requirements of NFPA 30, Flammable and Combustible Liquids Code, as referenced in Chapter 66 of NFPA 1; (6) The area where the finish is being applied shall be separated from the area where the sanding and reconditioning is being done by a one-hour fire-resistant partition wall. A communicating opening may be permitted between these two areas, provided, that the opening is protected by a self-closing Class "B" fire door and a six-inch-high, vapor-tight, noncombustible sill; (7) All electric wiring in the pin finishing area, to a height of eight feet above the floor level, shall conform to NFPA 70, National Electrical Code, for Class I, Group D, Division 1 hazardous locations, and to Division 2 hazardous locations above the eight-foot level. The electric wiring in the pin reconditioning area shall conform, throughout, to NFPA 70, National Electrical Code, for Class 2, Group G, Division 2; (8) The use, storage and handling of flammable liquids shall conform to all applicable sections of NFPA 30, Flammable and Combustible Liquids Code, as referenced in Chapter 66 of NFPA 1; (9) At least one approved egress door direct to the outside, hinged to swing outward, shall be provided for each room section. The doors shall be posted on the outside with a readily legible sign, "Danger, Keep Open Fire or Flame Away," and the room areas shall be posted on the inside with "No Smoking" signs; and (10) An approved fire extinguisher shall be located near the exit door in each room section. (c) Issuance of permit. Upon completion of the room as specified in Subsection (b) of this section, the Fire Marshal shall cause to be made an inspection of the premises and where, in the Fire Marshal's judgment, the intent of this division has been complied with, the Fire Marshal shall issue a bowling pin finishing permit. (d) Existing pin finishing and/or reconditioning rooms. The provisions of this division shall not be construed to require structural changes in existing pin finishing and/or pin reconditioning rooms or buildings unless the Fire Marshal determines, through investigation, that the existing conditions require such structural changes.

(Code 1984, § 19-1-33; Ord. No. 26-08, § 1(19-1-33), eff. 12-2-2008; Ord. No. 13-17, § 1(19-1-33), eff. 6-9-2017)

Ask a question about Detroit law

Corpus searches the Detroit sections it holds and shows the ones that match, with their citations. Free, no sign-in.