Sec. 19-3-981. - Intensity.

The light intensity shall be: (1) At least 108 lux (ten footcandles) at a distance of 75 cm (30 inches) above the floor, in walk-in refrigeration units and dry food storage areas and in other areas and rooms during periods of cleaning; (2) At least 215 lux (20 footcandles): a. At a surface where food is provided for consumer self-service such as buffets and salad bars or where fresh produce or packaged foods are sold or offered for consumption; b. Inside equipment such as reach-in and under-counter refrigerators; and c. At a distance of 75 cm (30 inches) above the floor in areas used for handwashing, warewashing, and equipment and utensil storage, and in toilet rooms; and (3) At least 540 lux (50 footcandles) at a surface where a food employee is working with food or working with utensils or equipment such as knives, slicers, grinders, or saws where employee safety is a factor.

(FDA Food Code 2009, § 6-303.11)