§ 19-3-981 — Intensity
2019 Detroit City Code (Supp. No. 4: codified through Ordinance No. 2024-17, effective March 26, 2024, and Ordinance No. 2024-32, effective June 25, 2024) · Detroit City Code § 19-3-981
Corpus is an independent public-information project, not the official City of Detroit website. Stable reference: corpuslaw.us/code/03e8ac44-fcb4-48d2-ad12-c2f85d40d6f9
Sec. 19-3-981. - Intensity.
The light intensity shall be: (1) At least 108 lux (ten footcandles) at a distance of 75 cm (30 inches) above the floor, in walk-in refrigeration units and dry food storage areas and in other areas and rooms during periods of cleaning; (2) At least 215 lux (20 footcandles): a. At a surface where food is provided for consumer self-service such as buffets and salad bars or where fresh produce or packaged foods are sold or offered for consumption; b. Inside equipment such as reach-in and under-counter refrigerators; and c. At a distance of 75 cm (30 inches) above the floor in areas used for handwashing, warewashing, and equipment and utensil storage, and in toilet rooms; and (3) At least 540 lux (50 footcandles) at a surface where a food employee is working with food or working with utensils or equipment such as knives, slicers, grinders, or saws where employee safety is a factor.
(FDA Food Code 2009, § 6-303.11)
Ask a question about Detroit law
Corpus searches the Detroit sections it holds and shows the ones that match, with their citations. Free, no sign-in.
