Sec. 42-2-180. - Fugitive dust monitoring.
Unless, either pursuant to the variance procedure set forth in Part V of this subdivision or because the facility does not include carbonaceous bulk solid materials and is enclosed in accordance with Section 42-2-203 of this Code, the facility owner or operator establishes that the facility's operations do not and will not result in off-site fugitive dust emissions, the owner or operator of the facility shall install, operate, and maintain around the perimeter of the facility, according to manufacturer's specifications, permanent, continuous Federal Equivalent Method (FEM) real-time PM10 monitors, or other sensors acceptable to the Buildings, Safety Engineering, and Environmental Department and the Health Department that provide equivalent information, in accordance with the following specific requirements: (1) During the first year of monitoring, at least two monitors must be located at opposite ends of the facility to monitor fugitive dust in the ambient air around the facility; (2) During the second and subsequent years of monitoring, monitors must be placed at the facility in compliance with an approved fugitive dust monitoring plan for the facility based on data collected from monitors placed under Subsection (1) of this section; (3) A data logger shall be attached to the monitors to record readings from the monitors, and the facility owner or operator shall notify the Buildings, Safety Engineering, and Environmental Department, in writing within 24 hours, each time the monitors exceed the reportable action level set forth in the fugitive dust plan and any time monitoring equipment has malfunctioned preventing readings or logging of data; and (4) The facility owner or operator shall maintain a log of all routine and non-routine maintenance and calibration activities associated with each fugitive dust monitor.
(Code 1984, § 22-5-19; Ord. No. 32-17, § 1(22-5-19), eff. 12-6-2017)
Ask a question about Detroit law
Corpus searches the Detroit sections it holds and shows the ones that match, with their citations. Free, no sign-in.