Sec. 50-11-275. - Intensity and dimensional standards.
Development in the SD2 Special Development District, Mixed-Use, is subject to Section 50-13-131 of this Code and as follows: (1) Front Setback. a. A minimum front setback is not required. b. The maximum front setback allowed shall be the average of the front setback of the buildings located on each side of the subject building or 20 feet, whichever is less. Parking in front of a neighboring building does not count as a front setback. c. Off-street parking shall be prohibited in the front setback. (2) Rear Setback. a. If a street or alley is to the rear of a single-story building, a minimum rear setback is not required. If no street or alley is present, single-story buildings shall have a minimum rear setback of ten feet. b. Where a single- or two-family dwelling is located across a street or alley from the rear of a multi-story building, the multi-story building shall have a rear setback of ten feet; where a street or alley is not present to separate the rear of a multi-story building from a single- or two-family dwelling, the multi-story building shall have a rear setback of 20 feet. c. Buildings containing dwelling units, other than single- or two-family dwellings, shall have a rear setback of ten feet if a street or alley is present at the rear and 20 feet if a street or alley is not present. (3) Side Setback. No minimum side setback is required except where a building is adjacent to land zoned R1, R2, R3, or R4. Where adjacent to land zoned R1, R2, R3, or R4, the side setback shall be calculated using Formula A. (4) Off-street parking location. Parking shall be prohibited between the street and front façade of the building. (5) Maximum height. 45 feet for nonmixed-use, 60 feet for mixed-use. Where a lot fronts on a right-of-way which is more than 60 feet wide and where the outermost point of the proposed mixed-use building is at least 40 feet from all R1, R2, and R3 Districts, the maximum height may be increased one foot for each one foot of right-of-way width greater than 60 feet. The mixed-use building must not exceed 80 feet in height.
(Ord. No. 2022-17, § 1, eff. 10-4-2022)
Ask a question about Detroit law
Corpus searches the Detroit sections it holds and shows the ones that match, with their citations. Free, no sign-in.