Sec. 50-12-161. - Manufactured housing units.

The term "manufactured housing" is defined in Section 50-16-301 of this Code. All manufactured housing units shall comply with the following requirements: (1) All dwelling units shall provide a minimum height between the floor and ceiling consistent with applicable codes; (2) There shall be a foundation of concrete or block around the entire exterior perimeter of all dwellings. The foundation shall have a minimum depth of 42 inches below grade. The foundation shall provide a maximum exposed foundation above grade of eight inches; (3) Where the dwelling unit does not have a basement, a crawl space is permitted within the requirements of Chapter 8, Article II, of this Code, Building Code. In the alternative, construction on slab may be permitted where the distance from the finished floor to the floor joists of the second floor is not less than eight feet; additionally, construction on slab may be permitted for a single-story dwelling where the distance from the finished floor to the ceiling is not less than eight feet; (4) All dwellings shall be firmly attached to their foundations so as to be watertight as required by Chapter 8, Article II, of this Code, Building Code, or anchored to the foundation by an anchor system designed and constructed in compliance with the United States Department of Housing and Urban Development Regulations entitled "Mobile Home Construction & Safety Standards"; (5) Any wheels, pulling mechanism, or tongues shall be removed prior to placement on a foundation; (6) All dwellings shall be connected to a sewer system and water supply system approved by the City; (7) Where there exists an elevation differential of more than one foot between any door and the surrounding grade, all dwellings shall provide steps or porch areas connected to each exterior door and permanently attached to the foundation. All dwellings shall provide a minimum of two points of ingress and egress. One exterior door shall face the front yard and a second exterior door shall face either the rear or side of the dwelling; (8) The dwelling shall not contain additions or rooms or other areas which are not constructed with similar or better quality work as the original structure, including permanent attachment to the principal structure and construction of a foundation as required in this section. All additions to dwellings shall meet all of the requirements of this chapter, this Code, and the Michigan Construction Codes; and (9) All dwellings shall have a minimum 4:12 roof pitch, with either a roof overhang of not less than six inches on all sides, or alternatively with window sills or roof drainage systems concentrating roof drainage at collection points along sides of the dwellings.

(Code 1984, § 61-12-120; Ord. No. 11-05, § 1(61-12-120), eff. 5-28-2005; Ord. No. 13-11, § 1(61-12-120), eff. 8-23-2011)

Ask a question about Detroit law

Corpus searches the Detroit sections it holds and shows the ones that match, with their citations. Free, no sign-in.