§ 50-13-237 — Bulk measurement and requirements; floor area ratio
2019 Detroit City Code (Supp. No. 4: codified through Ordinance No. 2024-17, effective March 26, 2024, and Ordinance No. 2024-32, effective June 25, 2024) · Detroit City Code § 50-13-237
Corpus is an independent public-information project, not the official City of Detroit website. Stable reference: corpuslaw.us/code/862fd0be-0de7-4548-87a6-17ae02794c65
Sec. 50-13-237. - Bulk measurement and requirements; floor area ratio.
The floor area ratio (FAR) shall be used to determine the maximum amount of floor area which may be built on a zoning lot. The maximum permitted floor area shall be determined by multiplying the zoning lot area, in square feet, by the floor area ratio (FAR) factor (see Figure 50-13-237). The resulting amount, which is the maximum permitted floor area, shall include all the floor areas of all the floors of a building on the zoning lot, measured from the exterior faces of exterior walls or from the centerlines of party walls and shall include elevator shafts and stairwells at each floor, interior balconies and mezzanines, and enclosed porches, but need not include the following areas: (1) Areas below the first or ground floor not used as a living room, a dining room, a kitchen, or sleeping accommodations; (2) Attic space that provides structural headroom of less than seven feet, six inches; (3) Unenclosed steps; (4) Any floor area that is devoted exclusively and permanently to noncommercial recreational use, but not to exceed 15 percent of the entire floor area of the building; (5) Any floor area, on or above the first or ground floor, that is devoted exclusively and permanently to the housing of building service equipment, including heating, air conditioning, mechanical, electrical, or similar equipment; (6) Exterior terraces, balconies and mezzanines, breezeways, and open porches; (7) Any space that is devoted exclusively to off-street parking or loading where said space is an integral part of a principal building, unless said building is a parking structure; (8) Floor spaces which are not more than 20 feet above grade plane and in accessory parking structures. Figure 50-13-237 (For Informational Purposes Only) Floor Area Ratio [image omitted; see the official code]
(Code 1984, § 61-13-157; Ord. No. 11-05, § 1(61-13-157), eff. 5-28-2005; Ord. No. 20-05, § 1(61-13-157), eff. 5-29-2005)
Ask a question about Detroit law
Corpus searches the Detroit sections it holds and shows the ones that match, with their citations. Free, no sign-in.
