§ 50-14-381 — Fences
2019 Detroit City Code (Supp. No. 4: codified through Ordinance No. 2024-17, effective March 26, 2024, and Ordinance No. 2024-32, effective June 25, 2024) · Detroit City Code § 50-14-381
Corpus is an independent public-information project, not the official City of Detroit website. Stable reference: corpuslaw.us/code/13733c63-6c9d-49c8-95e9-b8a3465dfc5d
Sec. 50-14-381. - Fences.
The following requirements shall apply with regard to fences: (1) Partition fences between houses. The respective owners of all lots in the City shall construct and maintain partition fences between their own and next adjoining lots in such manner as stated in this section, except that by mutual consent of adjoining owners such fences between dwellings may be omitted. All owners of lots shall be responsible for the rebuilding, care and upkeep of all fences that are contiguous to, or bordering upon, streets and alleys and also all fences that mark dividing lines between lots as specified in this section. The partition fence, to be erected and maintained, shall mean only that portion between the rear of the house and the alley or rear lot line; (2) Materials to be used. Except for screen walls and opaque walls as may be required in this division, all fences, constructed or reconstructed, shall be of 1⅝-inch iron pipe or two-inch angle irons embedded in concrete in the ground, or four-inch wood posts, or four-inch reinforced concrete posts or any other member of equal stability sunk in the soil at least three feet and that has a height above the average grade of the two adjoining lots of not less than two feet. On the posts shall be properly fastened woven wire, boards, metal or other approved materials. The junction of the post and boards or wire shall always be considered the lot line. The Buildings, Safety Engineering, and Environmental Department shall not be responsible for the establishing or locating the correct lot line between lots; (3) How constructed. The house numbering system of the City shall govern the side of the fence upon which the posts shall be placed. Posts of all fences shall be placed on the side of the fence leading to the higher number as assigned by the City, except only the fences on East and West Grand Boulevard and Outer Drive shall be governed as though the Grand Boulevard and Outer Drive were numbered as on parallel streets. The lot owner upon whose property the posts are located shall be responsible for building and maintaining the front half of the fence to be built, and the rear half of the opposite fence, notwithstanding that any previous ordinances are contrary. The posts of easement fences shall be placed on the side of the fence with the higher street number and the lot owner upon whose property the posts are located shall be responsible for building and maintaining the half of the fence adjacent to the next higher street number; (4) Fence height. a. In general. Fences between adjoining lots and on streets, alleys, and easements shall not be less than two feet in height or more than eight feet in height, except fences enclosing industrial or commercial properties may be 12 feet in height; and b. Single- and two-family dwellings. Notwithstanding Subsection (4)a of this section, the height of any fence that abuts the front yard of a single-family dwelling or two-family dwelling shall not exceed four feet, except that opaque fences shall not exceed three feet, provided, that in the event a deed restriction or historic district provision, which specifies front yard fencing in excess of four feet in height, a higher fence may be erected as so specified or required. The height of any fence that abuts the side yards or rear yard of a single-family dwelling or two-family dwelling shall not exceed six feet. Uses, on a lot adjoining the lot of a single-family dwelling or two-family dwelling, shall observe the preceding height limitations for any fence separating said use from the single- or two-family dwelling. (5) Barbed wire. a. On land zoned in a business or industrial district classification, fences of six feet or greater height may have barbed wire attached to arms or brackets which extend inward over private property, but no such barbed wire shall be placed at any point closer to the ground than six feet; and b. Notwithstanding Subsection (5)a of this section, no single-family dwelling or two-family dwelling may attach barbed wire to any fence. No use, on a lot adjoining the lot of a single-family dwelling or two-family dwelling, may attach barbed wire to any fence that separates said use from the single- or two-family dwelling. (6) Razor wire and electrified fencing. Razor wire and electrified fencing shall not be allowed in any residential, business, or special zoning district classification. Where permitted, razor wire shall not be placed at any point closer to the ground than six feet. (See also Section 8-2-20 in Chapter 8, Article II, of this Code, Building Code, and Sections 8-15-34, 8-15-107, 8-15-108, 8-15-109, and 8-15-201 in Chapter 8, Article XV, of this Code, Property Maintenance Code.)
(Code 1984, § 61-14-251; Ord. No. 11-05, § 1(61-14-251), eff. 5-28-2005; Ord. No. 20-05, § 1(61-14-251), eff. 5-29-2005; Ord. No. 44-06, § 1(61-14-251), eff. 12-21-2006)
Ask a question about Detroit law
Corpus searches the Detroit sections it holds and shows the ones that match, with their citations. Free, no sign-in.