Sec. 8-10-13. - Additions to Section 5 of ASME Standard, Mechanical Requirements.

Section 5 of the ASME Standard, Mechanical Requirements, is amended to read as follows: 5.1 Machines 5.1.1 Types. Machines shall be the direct-connected type. Cast-iron gears shall not be used. There shall be no 90 degree shoulders machined onto any shaft in manlift machines or pulleys. Machines shall be designed and constructed to catch and hold the driving pulley in the event of shaft failure. EXCEPTION: Existing multiple V-belt drive systems are permissible. All new installations shall be the direct-connected type. When one V-belt is replaced, all belts shall be replaced. 5.6 Handholds 5.6.2 Size. The grab surface of the handhold shall be not less than nine inches ( 230 m) in width or less than three inches (75 mm) in depth, and shall provide two inches (50 mm) of clearance from the belt. Fastenings for handholds shall be located at least one inch (25 mm) from the edge of the belt. 5.7 Safety stops 5.7.2 Lower limit safety stops. Two separate automatic safety stops shall be provided to shut off the electric power and apply the brake when a loaded step passes the bottom landing (refer to paragraph 4.6.2). One of these devices shall activate while the step is still in the horizontal position. The automatic safety stop may consist of one of the following: (a) A split-rail or equivalent safety stop located on the opposite guide rail. (b) An electronic devicer. (c) A treadle safety stop. No lower limit safety stops are required for a permanently installed riser, provided that it is ten inches (254 mm) in height or less from the floor. An automatic lower limit safety stop requiring manual resetting shall be installed to cut off the power and apply the brake when a loaded step passes the lower terminal landing and before the loaded step has reached a point 12 inches below the lower and terminal landing.

(Code 1964, §§ 5.3, 5.4, 5.5; Ord. No. 308-H, § 1(5.3, 5.4, 5.5), eff. 3-2-1979

Ask a question about Detroit law

Corpus searches the Detroit sections it holds and shows the ones that match, with their citations. Free, no sign-in.