§ 8-9-12 — Additions to Item 1.17 of Guide for Inspection of Elevators, Escalators, and Moving Walks, Standby Power Operation
2019 Detroit City Code (Supp. No. 4: codified through Ordinance No. 2024-17, effective March 26, 2024, and Ordinance No. 2024-32, effective June 25, 2024) · Detroit City Code § 8-9-12
Corpus is an independent public-information project, not the official City of Detroit website. Stable reference: corpuslaw.us/code/6620271c-9cae-4c5a-9cc8-7e39627fb944
Sec. 8-9-12. - Additions to Item 1.17 of Guide for Inspection of Elevators, Escalators, and Moving Walks, Standby Power Operation.
The City adds to Item 1.17 of the Guide for Inspection of Elevators, Escalators, and Moving Walks, Standby Power Operation, the following provisions: 1.17.3.1.1 Electric Elevators: Five-Year Test, Only One Elevator on Standby Power Supply. As outlined in Item 1.17.2.1 of this code, have the elevator placed on standby power. Place the rated load on the elevator (125 percent rated load for passenger elevators that are permitted to carry passengers) and operate the elevator observing for safe operation. Use a tachometer in the machine room to verify that the overhauling load does not cause a speed increase in excess of 125 percent of rated speed or the governor tripping speed. 1.17.3.1.1.1 Electric Elevators: Five-Year Test, More Than One Elevator Operating Simultaneously on Standby Power Supply. Have the elevators placed on standby power supply operation and loaded with the rated load (125 percent rated load for passenger elevators and freight elevators that are permitted to carry passengers) and operate all of the elevators simultaneously while observing that they operate normally and will safely lower, stop, and hold. Use a tachometer to check the speed of each elevator when operating simultaneously in both directions. Verify that each elevator stops at or near the terminal landing and before the final terminal stopping device operated. The speed should not exceed 125 percent of the rated speed or the governor tripping speed. 1.17.3.2.1 Hydraulic Elevators: Five-Year Test, Only One Elevator on Standby Power Supply. As outlined in Item 1.17.2.2 of this code, have the elevator placed on standby power. Place the rated load on the elevator (100 percent rated load for passenger elevators that are permitted to carry passengers) and operate the elevator observing for safe operation. Use a tachometer to verify that the rated load does not cause a speed increase. 1.17.3.2.1.1 Hydraulic Elevators: Five-Year Test, More Than One Elevator Operating Simultaneously on Standby Power Supply. Have the elevators placed on standby power supply operation and loaded with the rated load (100 percent rated load for passenger elevators and freight elevators that are permitted to carry passengers) and operate all of the elevators simultaneously observing that they operate normally and will safely lower, stop, and hold. Use a tachometer to check the speed of each elevator when operating simultaneously in both directions and to verify that the rated load does not cause a speed increase.
Ask a question about Detroit law
Corpus searches the Detroit sections it holds and shows the ones that match, with their citations. Free, no sign-in.