§ 50-155 — Exterior lighting
Code of Ordinances of the City of East Lansing, Michigan (Codified through Ordinance No. 1552, enacted August 12, 2025. (Supp. No. 16, Update 4)) · East Lansing Municipal Code § 50-155
Corpus is an independent public-information project, not the official City of East Lansing website. Stable reference: corpuslaw.us/code/8b0b431c-0ab1-41fe-9a8e-7e5c56bbdace
Sec. 50-155. - Exterior lighting.
A. Purpose. The purpose of this section is to provide reasonable regulations to direct the location, design, illumination level and use of outdoor lighting, and interior lighting directed towards the exterior, to minimize its undesirable effects. Specifically, this section is intended to promote the public health, safety and general welfare of the city by: 1. Maintaining safe night-time driver performance on public streets by minimizing both brightly lit surfaces and lighting glare; 2. Promoting lighting that provides security but protects the privacy of adjacent properties; 3. Allowing lighting that is not unduly intrusive or a nuisance to nearby residents, property occupants, and drivers; and 4. Eliminating intrusive artificial light and lighting that unnecessarily contributes to sky glow and energy consumption. [B.] [Requirements.] Exterior lighting in all zoning districts shall be subject to the following requirements: (1) Maximum fixture height. a. When adjacent to non-residentially used or zoned properties, exterior light fixtures shall not be mounted higher than 25 feet above grade. b. When adjacent to residentially used or zoned properties, exterior light fixtures shall not be mounted higher than 15 feet above grade. (2) Cutoff angle of light fixtures. a. All exterior light fixtures, including freestanding, canopy, pole, and building-mounted fixtures, as well as those used for single-family residential homes, shall be fully shielded and directed downward to prevent off-site glare and illumination. No portion of the lamp, reflector, lens, or refracting system may extend beyond the housing or shield, with the exception of pedestrian lighting. Interior light fixtures directed to the exterior of the building shall be subject to this requirement. b. Canopy mounted light fixtures shall be recessed into the canopy so as to limit visibility from surrounding properties or the public right-of-way. c. No lenses, lamps, or light sources shall be visible at the property line. d. The planning and zoning administrator may approve decorative light fixtures as an alternative to shielded fixtures when it can be demonstrated that there shall be no off-site glare or illumination and the proposed fixtures will improve the appearance of the site. (3) Lighting intended to illuminate building facades shall be directed entirely at the building, with the cutoff angle designed to prevent light from spilling directly into the sky. (4) The intensity of light within a site shall not exceed ten footcandles within any part of the site and one footcandle at any lot line, except where it abuts or faces a residential zone district or residential use, a maximum of 0.5 footcandles is permitted. For vehicle fuel stations or outdoor vehicle sales areas, a maximum of 20 footcandles may be approved on the site, subject to the requirements of subsection (2)c above. (5) To maintain uniformity in light levels across a development and prevent or minimize dark areas, the ratio of maximum to minimum lighting levels on a given lot is measured in footcandles at ground level, and shall not exceed a ratio of 15:1. Parking lots shall maintain the same uniformity ratios as the main building or principal use served.
(Ord. No. 1238, 8-9-2011; Ord. No. 1424, 6-5-2018; Ord. No. 1530, 5-21-2024)
Ask a question about East Lansing law
Corpus searches the East Lansing sections it holds and shows the ones that match, with their citations. Free, no sign-in.
