Sec. 50-463. - Required conditions.
The following requirements must be complied with in the RM-54 residential district. (1) Minimum lot area for multiple dwellings or portions thereof: Rooms | 600 sq. ft. Efficiency dwelling unit | 600 sq. ft. 1 bedroom dwelling unit | 700 sq. ft. 2 bedroom dwelling unit | 800 sq. ft. 3 or more bedroom dwelling unit | 1,000 sq. ft (2) Minimum lot width: none. (3) Minimum lot area: none. (4) Maximum building height: a. Principal building: four stories or 50 feet. b. Accessory building: two stories or 25 feet. c. Principal residential buildings located on a major street may be up to eight stories or 90 feet high, subject to an approved special use permit as provided by article II, division 3 of this chapter. d. Additional stories above the maximum building height may be added to principal residential buildings in accordance with the provisions of article VII, division 8, building and site incentives. (5) Maximum building coverage ratio: 40 percent. (6) Maximum ground coverage ratio: 80 percent. (7) Maximum floor area ratio: 2.0 times site area. (8) Required parking. Parking shall be provided in accordance with article VIII of this chapter. (9) Building setback requirements. a. Principal building. Minimum setback from: 1. Front property line: one foot for each two feet of building height. 2. Rear property line: one foot for each two feet of building height. 3. Side property line: one foot for each three feet of building height. b. Accessory building. No accessory building shall be located in a front yard. If located in a rear yard it shall be a minimum five feet from the rear or side property lines. If located in a side yard it shall be set back a distance equal to the required side yard for a principal building. (10) Minimum horizontal distance between buildings. a. Walls containing main window exposures or main entrances shall be located no closer to another building than a distance equal to the height of the taller building of the two. b. Other walls containing secondary windows (sides of buildings) shall be located no closer to another building than a distance equal to 60 percent of the height of the taller building of the two. (11) Minimum horizontal distance between building wings. The distance shall not be less than the projection of such wings, or equal to the height of the taller of the two wings, whichever is greater.
(Code 1994, ch. 55, § 5.41-43; Ord. No. 1087, pt. VII, 12-21-2004; Ord. No. 1276, 5-15-2012; Ord. No. 1536, 11-19-2024)
Ask a question about East Lansing law
Corpus searches the East Lansing sections it holds and shows the ones that match, with their citations. Free, no sign-in.