(a) The following definitions apply to lighting in this section: (1) Footcandle: The unit of measure expressing the quantity of light received on a surface. One (1) footcandle (fc) is the illuminance produced by a candle on a surface one (1) foot square from a distance of one (1) foot. (2) Fully shielded luminaire: A luminaire constructed and installed in such a manner that all light emitted by the luminaire, either directly from the lamp or a diffusing element, or indirectly by reflection or refraction from any part of the luminaire, is projected below the horizontal plane through the luminaire's lowest light-emitting part. (3) Full cutoff fixture: A luminaire light distribution where zero candela intensity occurs at an angle of ninety (90) degrees above nadir and at all greater angles from nadir. Also, the candela per one thousand (1,000) lamp lumens does not exceed one hundred (100) (ten (10) percent) at a vertical angle of eighty (80) degrees above nadir. (4) Glare: Lighting entering the eye directly from luminaires or indirectly from reflective surfaces that causes visual discomfort or reduced visibility. (5) Hardscape: Permanent hardscape improvements to the site including parking lots, drives, entrances, curbs, ramps, stairs, steps, medians, walkways and non-vegetated landscaping that is ten (10) feet or less in width. Materials may include concrete, asphalt, stone, gravel, etc. (6) Illuminance: A measure of how much light is arriving upon a surface, measured in footcandles (lumens per square foot) in the English system or lux (lumens per square meter) in the metric system. (7) Lamp: A generic term for a source of optical radiation (i.e., "light"), often called a "bulb" or "tube." Examples include incandescent, fluorescent, high-intensity discharge (HID) lamps, and low pressure sodium (LPS) lamps, as well as light-emitting diode (LED) modules and arrays. (8) Light trespass: Light that falls beyond the property it is intended to illuminate. (9) Lumen: The unit of measure used to quantify the amount of light produced by a lamp or emitted from a luminaire (as distinct from "watt," a measure of power consumption). (10) Luminaire: The complete lighting unit (fixture), consisting of a lamp, or lamps and ballast(s) (when applicable), together with the parts designed to distribute the light (reflector, lens, diffuser), to position and protect the lamps, and to connect the lamps to the power supply. (11) Luminance: The amount of light that reflects from the surface and reaches the eye of the observer. (12) Nadir: The angle that points directly downward, or zero (0) degrees, from the luminaire. (13) Skyglow: The brightening of the nighttime sky that results from scattering and reflection of artificial light by moisture and dust particles in the atmosphere. Skyglow is caused by light directed or reflected upwards or sideways and reduces one's ability to view the night sky. (14) Temporary lighting: Lighting installed and operated for periods not to exceed sixty (60) days, completely removed and not operated again for at least thirty (30) days. (15) Strip lighting. A device or devices installed that attract attention to a non-residential use wherein a source or sources of light are arranged to be visible from the exterior of a building or structure including, but not limited to, strips of LED lights or neon tubes placed along the perimeter of building windows, along building edges, and other locations that serve to attract attention to a non-residential use. This definition shall not include any device or devices classified as a sign by the definitions and regulations in the zoning ordinance. Temporary lights otherwise regulated by this section are also excluded from this definition. (b) Lighting shall be permitted and regulated as follows: (1) Exterior light under one thousand four hundred (1400) lumens. Exterior light sources with a lamp or lamps rated at a total of not more than one thousand four hundred (1400) lumens shall be permitted, except for flood or spotlights and illumination at building entrances, as permitted in the zoning ordinance (section 34-5.16.3). (2) Flood or spotlights. Flood or spotlights used for the external illumination of buildings, signs, or flags with a lamp or lamps rated at nine hundred (900) lumens or less shall be permitted in any use district, provided that such lighting is not aimed, directed, or focused toward residential districts or uses or toward a public street, so that there is no interference with the vision or comfort of persons on public streets or in residential districts or uses (see section 34-5.16 in the zoning ordinance for additional requirements that apply to uses or developments that require site plan approval). (3) Exterior lights of more than one thousand four hundred (1400) lumens. Exterior lighting with a lamp or lamps of more than one thousand four hundred (1400) lumens will be permitted, provided that the light source is down-lit to reduce intensity and glare and is so arranged as to reflect lights away from all adjacent residential districts or uses and from adjacent public streets. Additionally, the light diffusing media shall be totally shielded with opaque material on the top and all sides, and the light source shall be parallel to the horizontal plane of the area to be lighted (see section 34-5.16 in the zoning ordinance for additional requirements that apply to uses or developments that require site plan approval). (4) Security lighting. Notwithstanding any other provision of this section 17-106, security lighting that is controlled by a properly-functioning motion detector and which does not remain on longer than ten (10) minutes after activation shall be permitted, provided that such lighting is not aimed, directed, or focused toward residential districts or uses or toward a public street, so that there is no interference with the vision or comfort of persons on public streets or in residential districts or uses. (5) Interior lighting. Interior lighting shall be subject to subsection 17-106(b). (6) Conformance with all applicable codes. All outdoor lighting shall be installed in conformance with the provisions of this section, applicable electrical and energy codes, and applicable sections of the building code. (7) Applicability. Except where exempt, all outdoor lighting shall comply with these requirements. This includes, but is not limited to, new lighting, replacement lighting, or any other lighting whether attached to structures, poles, the earth, or any other location, including lighting installed by any third party. Lighting within public right-of-way or easement for the principal purpose of illuminating streets or roads is not subject to this section. (8) Fully shielded luminaires. All light fixtures shall be fully shielded luminaires, except as provided elsewhere in this section. (9) Light trespass. All outdoor light fixtures shall be installed and maintained in such a manner that does not permit light trespass beyond the property boundary as specified in this section. Further any fixed objects that reflect or diffract light, such as windows, mirrors, or other reflective objects must not permit light trespass. (10) Color of illumination. The use of sodium or metal halide lamps is prohibited, unless color-corrected lamps are used. (11) Electrical service. Electrical service to light fixtures installed after the effective date of this section shall be placed underground where feasible. (12) Façade lighting. All façade lighting must be restricted to the façade surface and may only be used to highlight specific architectural features. Light trespass is prohibited. (13) Security lighting. Lighting for security purposes shall be directed only onto the area to be secured. a. All fixtures shall be located, shielded and aimed so that light is not cast toward adjacent properties or streets or unnecessarily transmitted into the night sky. b. Fixtures mounted on the building and designed to illuminate the façade are preferred. (14) Adjacent residential property. Exterior and interior lighting shall not cause an illuminance that is greater than one (1) footcandle within two (2) feet of the wall of any main building in an adjacent residential property (see section 34-5.16 of the zoning ordinance for additional requirements that apply to uses or developments that require site plan approval). (15) Flashing, moving, intermittent light. All illumination of signs and any other outdoor features shall not be of a flashing, moving or intermittent type. Artificial light shall be maintained stationary and constant in intensity and color at all times when in use. (16) Strip lighting. Strip lighting designed for or having the effect of illuminating the exterior of non-residential establishments shall meet the following: a. No direct light source shall be visible from any street or adjacent residential property unless the direct source is obscured or softened in appearance by use of a diffusing material. b. Lights shall not flash, blink, strobe, or create the impression of movement. c. Lights shall not change color. d. The brightness of strip lighting shall be limited to 0.3 footcandles above ambient light conditions, as measured from the property line or lines nearest to each source of illumination. (c) The following uses shall be exempt from the provisions of this section: (1) Roadway and airport lighting required by the appropriate public agency for health, safety and welfare purposes; (2) Construction lighting approved by the building department as part of a building permit; (3) Flag lighting, provided that the illumination is the minimum level necessary, and that the light source is aimed and shielded to direct light only onto the intended target and to prevent glare for motorists and pedestrians; (4) Emergency lighting approved by the city, provided the lighting is discontinued upon the abatement of the emergency necessitating said lighting; and (5) Other temporary lighting determined to be reasonable and appropriate by the City of Farmington Hills Building Official. (d) An application for a special exception from the provisions of this section may be submitted to the zoning board of appeals, sitting as an administrative review board for purposes of this provision. If it appears to the zoning board of appeals, in its course of review of the applicant's application, that the expertise of a lighting consultant or other expert shall be necessary in order to review the application, the zoning board of appeals shall be authorized to obtain a reasonable escrow for consulting fees from the applicant and retain such expert for such purposes. The zoning board of appeals may grant a special exception where such relief will be within the spirit and intent of this section, would not adversely affect the public health, safety and welfare, and would not be materially injurious to surrounding properties and improvements. The zoning board of appeals may impose conditions in connection with the granting of a special exception.
(Ord. No. C-10-2004, § 1, 8-23-04; Ord. No. C-7-2013, § 1, 8-12-13; Ord. No. C-6-2016, § 1, 11-14-16)
Ask a question about Farmington Hills law
Corpus searches the Farmington Hills sections it holds and shows the ones that match, with their citations. Free, no sign-in.