Sec. 33-35. - Building sewer specifications.

House connection sewage from lateral sewer in street or easement to within five (5) feet from house shall be done in accordance with city standards and specifications as established by resolution of the council. (1) Six-inch full diameter extra strength vitrified sewer pipe manufactured in accordance with current N.C.P.I. Designation ER4-67 Standards, or equal, with county department of public works approved premium joint; (2) Six-inch diameter Class 2400 asbestos cement pipe with ring-tite, fluid-tite or county department of public works approved joint; (3) Six-inch diameter, service strength, cast-iron soil pipe, hot poured lead joint, or approved equal; or (4) Other pipe and joints as may be approved by the county department of public works.

(Code 1981, § 14.100)