§ 14.04 — Site plan information requirements
Code of Ordinances of the City of Kentwood, Michigan (Codified through Ordinance No. 6-26, adopted June 2, 2026. (Supp. No. 18)) · Kentwood Code of Ordinances § 14.04
Corpus is an independent public-information project, not the official City of Kentwood website. Stable reference: corpuslaw.us/code/0957174b-e829-49c6-acb6-7b5ed6e2ccfa
Section 14.04. - Site plan information requirements.
The following information shall be included with and as part of the site plan submitted for review. Each category of site plan items shall be included on a separate sheet. The Planning Commission shall not review incomplete applications. Where circumstances warrant the zoning administrator or Planning Commission has the discretion to eliminate or add to any of the following items as required information or may allow the information to be organized differently than as listed below: Required Site Plan Data | Prelim Site Plan | Final Plan A. All Sheets All sheets shall be drawn to an engineer's scale of not less than one inch = 50 feet for a site less than three acres, or one inch = 100 feet for a site of three acres or more; sheet size should be at least 24 × 36 inches; for large developments shown in sections on multiple sheets, an overall composite sheet shall be included. | • | • Title block with sheet number/title; name, address and telephone number of the applicant and firm or individual who prepared the plans; and date(s) of submission and any revisions (month, day, year) | • | • Scale and northpoint | • | • Identification and seal of architect, engineer, land surveyor, or landscape architect who prepared drawings | • | • B. Project and Site Data Written project description, including proposed use, building(s) and site improvements | • | • Location map with north-point, showing surrounding land, and streets within a quarter mile | • | • Legal and common description of property | • | • Zoning classification of petitioner's parcel and all abutting parcels | • | • Proximity to major thoroughfares | • | • Net acreage (minus rights-of-way) and total acreage | • | • C. Site Analysis Survey of existing lot lines, building lines, structures, parking areas and other improvements on the site and within 100 feet of the site | • | • Location of existing drainage courses, floodplains, lakes and streams, and wetlands with elevations | • | • Surface drainage flows including high points, low points and swales | • | • All existing easements | • | • Existing roadways and driveways within 100 feet of the site | • | • Existing sidewalks and nonmotorized pathways | • | • D. Site Plan Details Proposed lot lines, lot dimensions, property lines and setback dimensions | • | • Building, structure, parking and driveway improvements | • | • Proposed easements | • | • Location of exterior lighting (site and building) in accordance with chapter 20 | • Location of trash receptacle(s) and transformer pad(s) and method of screening | • E. Access and Circulation Dimensions, curve radii and centerlines of existing and proposed access points, roads and road rights-of-way or access easements | • | • Cross section details of proposed roads, driveways, parking lots, sidewalks and nonmotorized paths illustrating materials and thickness | • Dimensions of acceleration, deceleration, and passing lanes | • Dimensions of parking spaces, islands, circulation aisles and loading zones | • | • Calculations for required number of parking and loading spaces | • | • Designation of fire lanes | • Traffic regulatory signs and pavement markings | • Location of existing and proposed sidewalks/pathways within the site or right-of-way | • Traffic impact study, where required | • | • F. Building and Structure Details Location, height, and outside dimensions of all proposed buildings or structures | • | • Building floor area by use (e.g., office, retail, warehouse) and total floor area | • | • Location, size, height, and lighting of all proposed site and wall signs | • Location and type of obscuring wall(s) or berm(s) where required | • | • Location, type, size, height and material of construction for all obscuring wall(s) or berm(s) with cross sections, where required | • Building facade elevations for all sides, drawn at an appropriate scale | • Description of exterior building materials and colors (samples may be required) | • G. Drainage, Soil Erosion and Sedimentation Control Location and size of existing and proposed storm sewers; and retention and detention ponds | • | • Stormwater retention and detention ponds, including grading, side slopes, depth, high water elevation, volume and outfalls | • Stormwater drainage and retention/detention calculations | • Indication of site grading, drainage patterns and stormwater management measures | • Soil erosion and sedimentation control measures | • Existing and proposed contours | • | • H. Utilities Location of sanitary sewers and septic systems, existing and proposed | • | • Location and size of existing and proposed water mains, well sites, water service and fire hydrants | • | • I. Additional Information Required for Residential Developments The number and location of each type of residential unit (one bedroom units, two bedroom units, etc.) | • | • Density calculations by type of residential unit (dwelling units per acre) | • | • Garage and/or carport locations and details, if proposed | • | • Location, dimensions and elevations of common building(s) (e.g., recreation, laundry, etc.), if applicable | • Swimming pool fencing detail, including height and type of fence, if applicable | • Location and size of recreation and open space areas | • | • Indication of type of recreation facilities proposed for recreation area | • | • For condominium projects, master deed and bylaws | • J. Landscape plan (See chapter 19) Description of methods to preserve existing plant materials | • The location of existing and proposed landscaped areas | • | • Location and type of all proposed shrubs, trees, and other live plant material | • | • Planting list for proposed landscape materials with caliper size or height of material, method of installation, botanical and common names, and quantity | • Table demonstrating compliance with all landscaping calculation requirements that lists required and proposed amount of plantings | • Proposed dates of plant installation | • K. Lighting Plan (See chapter 20) Location of all freestanding, building-mounted and canopy light fixtures on the site plan and building elevations | • | • Photometric grid overlaid on the proposed site plan indicating the overall light intensity throughout the site (in footcandles) | • Specifications, graphic depiction, and details for the type of fixture being proposed including the total lumen output, type of lamp and method of shielding | • Use of the fixture proposed | • | •
(Ord. No. 7-03, § 11(14.04), 4-1-2003)
Ask a question about Kentwood law
Corpus searches the Kentwood sections it holds and shows the ones that match, with their citations. Free, no sign-in.