Sec. 70-384. - Grease, oil and sand interceptors.
(a) All establishments where food is manufactured, sold, or prepared, except for small areas designated as employee break areas or the equivalent discharging wastewater containing fats, oils, and grease (FOG) to the system shall install, operate, and maintain a sufficiently sized oil and grease, water and solids separator (hereinafter called grease trap) necessary to achieve and maintain compliance with the limits indicated in section 86-292. (b) Unless otherwise authorized by the director, all grease traps shall be of the outdoor, inline variety. With special authorization by the director, grease traps of the indoor, under-counter, stand-alone variety may be allowed. In this case, maintenance of indoor grease traps shall be performed at frequencies necessary to protect the capacity of the sewer system against accumulation of grease and oils, as required by the "25% rule" as defined herein. Under no condition shall an indoor grease trap be cleaned at intervals less frequent than once every 14 days. (c) Grease, oil and sand interceptors shall be provided when they are necessary for the proper handling of liquid wastes containing grease in excessive amounts or any flammable wastes, sand or other harmful ingredients. Such interceptors shall not be required for dwelling units. All interceptors shall be of a type and capacity approved by the director and shall be located so as to be readily accessible for cleaning and inspection. (d) Grease and oil interceptors shall be constructed of impervious materials capable of withstanding abrupt and extreme changes in temperature. They shall be of substantial construction, watertight and equipped with easily removable covers which, when bolted in place, shall be gastight and watertight. (e) Where installed, all grease, oil and sand interceptors shall be cleaned and maintained by the owner and shall be operated continuously in an efficient manner whenever the facility is in operation. The city shall have the right to inspect maintenance and disposal records related to the operation of grease, oil and sand interceptors. (f) The user shall be responsible for the proper removal and legal disposal of the grease trap waste. All waste removed from each grease trap must be disposed of at a facility permitted to receive such waste. No grease trap pumpage may be discharged to the city sewer system. Maintenance shall include the complete removal of all contents, including floatable materials, wastewater, sludges and solids and jet flushing to remove measurable build-up on tank walls. Top skimming of outdoor grease traps, decanting or back flushing of the grease trap or its wastes for the purpose of reducing the volume to be hauled is prohibited. (g) There shall be ample room and reasonable access to interceptors to allow accurate sampling and preparation of samples for transport and analysis. (h) Grease traps and other interceptors shall be installed in compliance with the current plumbing codes adopted by the city. The director shall make final determination and approval of a grease trap's size. If additional pretreatment and/or maintenance is required to meet the provisions in this section, the director, may require that the establishment in existence prior to the effective date of this section upgrade to the requirements provided. (i) Maintenance of an outdoor grease trap shall be performed at frequencies necessary to protect the capacity of the sewer system against accumulation of grease and oils, as required by the "25 percent rule" and at intervals no less than once every 90 days. (j) Use of any bacteriological, chemical, or enzymatic addition for the purpose of maintaining a grease trap is prohibited unless written approval is obtained from the director. (k) The user shall be responsible for maintaining records and/or manifests as to the dates of service, quantity, and waste hauler name at the user's location for a period of three years, which records shall be subject to review by the city without prior notification. Should any user fail to properly clean and maintain a grease trap as required herein, the city, at its option may contract for appropriate cleaning and maintenance by a licensed contractor, the cost of which shall be collectable by the city from the user at a charge of actual cost plus 100 percent.
(Code 2004, § 70-384; Ord. No. 5-11, § 1, 9-2-2011; Ord. No. 13-24, § 1, 9-3-2024)
Ask a question about Kentwood law
Corpus searches the Kentwood sections it holds and shows the ones that match, with their citations. Free, no sign-in.