§ 70-411 — Discharge standards and limits
Code of Ordinances of the City of Kentwood, Michigan (Codified through Ordinance No. 6-26, adopted June 2, 2026. (Supp. No. 18)) · Kentwood Code of Ordinances § 70-411
Corpus is an independent public-information project, not the official City of Kentwood website. Stable reference: corpuslaw.us/code/abecae74-e32a-4652-8b34-3bfe782b2004
Sec. 70-411. - Discharge standards and limits.
(a) All nonresidential users who discharge compatible pollutants shall be subject to the requirements itemized below. (1) Background standards. Unless specially authorized via approval of the director and issue of a wastewater discharge permit, no wastewater containing pollutants in excess of the following background levels shall be discharged: Parameter | Daily Average Concentration (mg/l) 5-day BOD | 240 Suspended solids | 220 Phosphorus | 6.4 Fats, oil and grease | 51 Ammonia nitrogen | 22.9 (2) User-specific maximum limits. Upon approval of the director and issuance of a wastewater discharge permit, and if the discharge complies with the requirements of subsection (a)(3) of this section, wastewater not in excess of user-specific maximum mass limits may be discharged. These limits will be established by the director by an appropriate allocation of the wastewater treatment plant's approved maximum allowable headworks loadings for the following parameters: Parameter | MAHL (lb/day) 5-day BOD | 68,000 Suspended solids | 51,600 Total phosphorus | 1,800 (3) General maximum limits. Upon approval of the director and issuance of a wastewater discharge permit, wastewater containing pollutants not in excess of the following maximum concentration limits may be discharged: Parameter | Daily Average Concentration (mg/l) | Single Grab Concentration (mg/l) Fats, oils and grease | 470 | 830 (4) Surcharge threshold standards. Discharges of compatible pollutants shall also be subject to a surcharge in accordance with section 70-361 when exceeding any of the following baseline levels: Parameter | Daily Average Concentration (mg/l) 5-day BOD | 340 Suspended solids | 355 Phosphorus | 9.1 Fats, oil and grease | 96 (b) All nonresidential users who discharge incompatible pollutants shall be subject to the requirements itemized below. (1) Primary toxic pollutants. a. Background standards. Unless specially authorized via approval of the director and issuance of a wastewater discharge permit, no wastewater containing pollutants in excess of the following background levels shall be discharged: Parameter | Daily Average Concentration (mg/l) | MAHL (lb/day) Arsenic, total | 0.00716 | 9.99 Cadmium | 0.00 | 2.03 Chromium, total | 0.00175 | 43.9 Copper, total | 0.0595 | 87.6 Lead, total | 0.00544 | 70.0 Mercury, total | 0.000121 | 0.00214 Molybdenum, total | 0.002 | 10.6 Nickel, total | 0.003 | 27.1 Selenium, total | 0.0112 | 8.33 Silver, total | 0.0118 | 11.5 Zinc, total | 0.127 | 187.0 Cyanides, total | 0.00282 | 4.01 b. General maximum limits. Upon approval of the director and issuance of a wastewater discharge permit, wastewater not in excess of the following limits may be discharged: Parameter | Daily Average Concentration (mg/l) | Single Grab Concentration (mg/l) Arsenic, total | 0.29 | 1.3 Cadmium, total | 0.094 | 0.33 Chromium, total | 2.1 | 5.4 Copper, total | 2.4 | 5.3 Lead, total | 2.5 | 4.6 Molybdenum, total | 0.51 | 1.4 Nickel, total | 1.3 | 2.6 Selenium, total | 0.33 | 1.4 Silver, total | 0.37 | 2.7 Zinc, total | 5.0 | 6.0 Cyanides, total | 0.18 | 0.91 Notes: Based on discharge of any or all of the following phenolic compounds: 2-Chlorophenol; 4-Chlorophenol; 2,4-Dichlorophenol; 2,4-Dimethylphenol; 2,4-Dinitrophenol; 2-Methylphenol; 4-Methylphenol; 2-Nitrophenol; 4-Nitrophenol; and phenol. Discharge of other phenolic compounds is prohibited, except as specifically authorized by the director. If a discharge exceeds this total phenols limit, the affected user may petition the director for an alternative individual phenolic limit in accordance with subsection (b)(4) of this section. (2) Secondary toxic pollutants. a. Background standards. Unless specially authorized via approval of the director and issuance of a wastewater discharge permit, no wastewater containing pollutants in excess of the following background levels shall be discharged: Parameter | Daily Average Concentration (mg/l) Acetone(2-Propanone) | 0.0758 Bromodichloromethane | 0.00159 Butylbenzylphthalate | 0.00668 di-n-Butylphthalate | 0.00406 Chloroform | 0.00623 Dibromochloromethane | 0.00199 1,4-Dichlorobenzene | 0.00279 bis 2-Ethylhexyl Phthalate | 0.0265 4-Methylphenol (p-Cresol) | 0.0908 Phenol | 0.0158 Toluene | 0.000938 Notes: Where background levels in normal tap water exceed any of the indicated concentrations, the city may grant an exemption to requiring a wastewater discharge permit if it is adequately demonstrated that no other discharge of the corresponding substance occurs from the discharger's facility. b. General maximum limits. Upon approval of the director and issuance of a wastewater discharge permit, wastewater containing pollutants not in excess of the following limits may be discharged: Parameter | Daily Average Concentration (mg/l) Acetone(2-Propanone) | 620 Benzene | 0.61 Bromodichloromethane | 0.71 2-Butanone (Methyl ethyl ketone) | 650 di-n-Butylphthalate | 0.91 Carbon Tetrachloride | 0.13 Chlorobenzene | 2.4 Chloroform | 0.64 4-Chloro-3-methyl phenol (p-Chloro-m-Cresol) | 0.86 Dibromochloromethane | 0.75 1,2-Dichlorobenzene | 2.1 1,3-Dichlorobenzene | 0.31 1,4-Dichlorobenzene | 0.40 1,2-Dichloroethane | 0.35 1,1-Dichloroethylene | 1.9 1,2-Dichloroethylene | 4.5 1,2-Dichloropropane | 0.34 2,4-Dimethylphenol | 4.3 Ethylbenzene | 0.98 bis 2-Ethylhexyl phthalate | 0.16 Isophorone | 30 Methylene chloride | 1.1 2-Methylphenol (o-Cresol) | 6.5 4-Methylphenol (p-Cresol) | 3.1 Naphthalene | 2.0 Phenol | 32 1,1,2,2-Tetrachloroethane | 0.12 Tetrachloroethylene (Perchloroetylene) | 0.05 Toluene | 3.5 1,1,1-Trichloroethane | 2.0 1,1,2-Trichloroethane | 0.23 Trichloroethylene | 0.54 Vinyl chloride | 0.05 Xylenes, total | 0.94 (3) Tertiary toxic pollutants. a. Background standards. Unless specially authorized via approval of the director and issuance of a wastewater discharge permit, no wastewater containing pollutants in excess of the following background levels shall be discharged: Parameter | Daily Average Concentration (mg/l) Benzoic acid | 0.0166 Diethylphthalate | 0.00873 2-Methylnaphthalene | 0.0178 b. User-specific maximum limits. Upon approval of the director and issuance of a wastewater discharge permit, and if the discharge complies with the requirements of subsection (c) of this section, wastewater not in excess of user-specific maximum limits may be discharged. These limits will be established by the director via an appropriate mass allocation of the wastewater treatment plant's approved maximum allowable headworks loadings for the following parameters: Parameter | MAHL (lb/day) Benzoic acid | 15.9 Carbon disulfide | 4020 Chloroethane | 167 Diethylphthalate | 111 1,1-Dichloroethane | 23 Ethyl ether (Diethyl ether) | 107 2-Hexanone (Methyl-n-butyl ketone) | 5.420 Hexone (Methyl isobutyl ketone; 4-Methyl-2-pentanone) | 0.178 2-Methylnaphthalene | 244 N-Nitrosodiphenylamine | 0.743 Phenanthrene | 4.79 2,4,5-Trichlorophenol | 2.65 (4) Individual phenolic compounds. If a discharge exceeds the total phenols limit of subsection (b)(1) of this section, the affected user may petition the director for an alternative individual phenolic compound limit. Included with this petition shall be a "phenol characterization plan" that shall aim to identify and quantify the specific phenolic compounds present in the discharge. If the director deems the plan approvable and concurs with the results of the subsequent study, if the specific compounds present in the discharge are included in those authorized herein, and if the discharge complies with the requirement of subsection (c) of this section, the total phenols limit may be replaced with one or more of the following alternative user-specific maximum limits that will be established by the director via an appropriate mass allocation of the wastewater treatment plant's approved maximum allowable headworks loadings: Parameter | MAHL (lb/day) 2,4-Dimethylphenol | 543 2-Methylphenol (o-Cresol) | 248 4-Methylphenol (p-Cresol) | 75 Phenol | 1440 (c) All discharges with user-specific maximum limits established in accordance with subsections (a)(2), (b)(3)b, and (b)(4) of this section will be subject to all of the following additional requirements: (1) The discharge shall be monitored by continuous on-line flow measuring and recording devices, including the capability to calculate actual average daily flow. (2) The discharge shall be monitored via an automatic sampler that is controlled via an input signal from the flow measuring device of subsection (c)(1) of this section, so as to produce a flow-proportioned composite sample. (3) The associated wastewater discharge permit shall include both average daily flow and concentration limits (daily average and single grab) as enforceable conditions.
(Code 2004, § 70-411; Ord. No. 5-11, § 1, 9-2-2011)
Ask a question about Kentwood law
Corpus searches the Kentwood sections it holds and shows the ones that match, with their citations. Free, no sign-in.