§ 1245.03 — Industrial and institutional permitted uses
Code of Ordinances of the City of Lansing, Michigan (Codified through Ordinance No. 1343, adopted October 27, 2025 (Supp. No. 64)) · Lansing Codified Ordinances § 1245.03
Corpus is an independent public-information project, not the official City of Lansing website. Stable reference: corpuslaw.us/code/347e97ae-73f2-4907-8135-4017d87b11e6
1245.03. - Industrial and institutional permitted uses.
In Industrial and Institutional Districts, the following principal uses are permitted. Permitted uses shall be subject to site plan review. Conditional uses are permitted if the conditions noted in the section referenced are met. Special land uses may be permitted by Council in accordance with the procedures and review standards described in Chapter 1262 - Special Land Use Permits. P = PRINCIPAL PERMITTED C = CONDITIONAL USE S = SPECIAL LAND USE | IND-1 | INST-1 | Conditions Industrial Cleaning, processing, servicing, or repair of any product | P Dry cleaning plants | C | 1. All activities conducted and materials stored shall be within an enclosed structure so as to not produce any objectionable noise, vibration, smoke, dust, dirt, toxic or offensive odors or gases, or glare. 2. Methods to minimize the impact of excessive noise on adjacent residentially used properties are required. Industrial metal forming and scrap metal processing | P Logistics terminal, wholesale and warehouse uses | P Industrial: Assembly, fabrication, manufacturing, production, and recycling | C | 1. All activities conducted and materials stored shall be within an enclosed structure so as to not produce any objectionable noise, vibration, smoke, dust, dirt, toxic or offensive odors or gases, or glare. 2. Methods to minimize the impact of excessive noise on adjacent residentially used properties are required. Non-hazardous assembly, fabrication, production and manufacturing of consumer goods, with retail sales | C | 1. All activities conducted and materials stored shall be within an enclosed structure so as to not produce any objectionable noise, vibration, smoke, dust, dirt, toxic or offensive odors or gases, or glare. 2. Methods to minimize the impact of excessive noise on adjacent residentially used properties are required. Motor vehicle repair station | C | 1. All activities conducted and materials stored shall be within an enclosed structure so as to not produce any objectionable noise, vibration, smoke, dust, dirt, toxic or offensive odors or gases, or glare. 2. Methods to minimize the impact of excessive noise on adjacent residentially used properties are required. 3. Materials, junk, or junk vehicles shall be stored on-site and shall be within an enclosed building or on a hard surface in the rear yard and screened by a six-foot opaque fence. Motor vehicle sales, vehicle leasing, and other outdoor sales facility; general | C | 1. The area of the lot on which the items displayed for sale are located shall be covered with Portland cement or asphaltic concrete. 2. Each point of vehicular ingress and egress to the lot shall be not less than 60 feet from the intersection of any two streets. 3. Any repair or refinishing which is done on the lot shall be done within the confines of an enclosed structure. 4. Any vehicles awaiting repairs must be stored in the side or rear yard and screened from the public right-of-way. 5. Lighting shall be confined within and directed onto the parking area only. 6. The area of the lot on which the items displayed for sale are located shall be at least eight feet from all lot lines adjacent to the public right-of-way, excluding approved driveways, and any residentially zoned property. The buffer zone shall be landscaped, screened and buffered in accordance with the requirements of Section 1252.08. 7. No junk, junk vehicles, or inoperable vehicles shall be stored on-site except within an enclosed building. Sales and leasing of: commercial or industrial vehicles, equipment, and machinery; recreational vehicles and equipment | C Motor vehicle service station | C | 1. For a building located on a corner lot, the secondary front facade may occupy no less than 50 percent of the frontage. The remainder of the frontage not occupied by the building shall be screened per the parking standards of the district. 2. The fueling pumps shall be located a minimum of 20 feet behind the build-to line. 3. The canopy over the fueling pumps shall have a roof with the same slope as the principal building. Canopy clearance should not exceed 14 feet from the ground to the bottom of the canopy. Maximum canopy height is limited to 20 feet. 4. One access per street frontage however a second access may be approved by City staff upon a finding that the additional access is essential for convenient access, and that the access is spaced adequately and designed to minimize conflicts per Section 1254.01.11. A secondary access drive is permitted for shared access with adjacent parcels. 5. Vehicle sales or leasing shall not be accessory to the principal use. 6. Materials, junk, or junk vehicles shall be stored on-site and shall be within an enclosed building or on a hard surface in the rear yard and screened by a six-foot opaque fence. Power plants, solar array | P Research laboratory | P | P Salvage yards/junk yards; open storage; lumber yard, vehicle towing and storage | C | 1. The materials shall be enclosed by a structure or a fence, not less than eight feet in height, that obstructs vision from all property lines. 2. The materials stored within 30 feet of the fence shall not exceed the height of the fence. 3. A plan is submitted to and approved by the Zoning Administrator, which shows the type and location of the fence. 4. No outdoor burning occurs on the lot on which the salvage yard is located. 5. No objectionable noise, vibration, smoke, dust, dirt, toxic or offensive odors or gases, or glare shall extend past the subject property lines. Sanitary land fill | S Self-storage rental | P Tool, die, and machine shops | P Infrastructure | P | S Wireless communications towers | S Adult business uses | S | See Section 1250.02.11 Residential Uses Two-family dwelling | P Multi-family dwelling | C | P | In industrial districts, multiple-family only as part of renovation of or addition to an existing structure. Human Care Facilities Adult day care facility | S Adult foster care (≤ 6) | P AFC small group home | P AFC large group home (13—20) | S AFC congregate care | S Child care centers, preschools, and commercial day care | P | P Convalescent or nursing home | P Sheltered care facility | S | 1. At least one property line abutting a Major Arterial street type. 2. The proposed sheltered care facility is located more than 1,500 feet from an existing sheltered care facility which provides care for more than six persons. Civic and Institutional Hospital | P Park, open space, plaza | P | P Places of worship | S | S Trade school | P | P Museum | C | P | 1. Front, rear and side yards are not less than 25 feet, except as provided below. 2. If a front, rear or side yard abuts a Commercial Mixed-Use District, then the yard which abuts such district shall meet the dimensional requirements of the district which abuts such front, rear or side yard. 3. No parking exists in the front yard. 4. No accessory structure is located in the front yard. Library | C | P Schools | C | All education facilities, except elementary or middle schools, must have at least one property line abutting and all points of ingress/egress directly to an arterial, suburban or activity corridor Commercial/Office Retail sales and personal services | P | P Professional/businesses offices | P | P Active/recreational commercial | P | P Animal hospital | C | C | All operations must be completely enclosed in a soundproof building in such a way as to produce no objectionable noises or odors at the lot lines. Bank | P | P Boarding house | P | 1. Permitted on non-local streets. 2. Staff must be on-site or on-call 24 hours a day Clinic | P | P Funeral home | P | P Kennel | C | 1. Structures must be setback at least 50 feet from each adjacent residential lot line. 2. Outside exercise run or treatment area shall be screened and must be located at least 100 feet from all lots lines and at least 300 feet from an adjacent residential lot line. 3. All operations must be controlled in such a way as to produce no objectionable noises or odors at the lot lines. Laundromat, dry cleaner | P | P Lodging facility | P | C | Permitted on non-local streets Mobile food vending (food trucks and carts) | C | C | See Section 1250.02.12 Nursery, commercial greenhouse | P Parking facility | S | S | 1. On activity corridors, the first floor shall have a minimum depth of 20 feet to be occupied by commercial uses permitted in the district. 2. Access drives shall be permitted on the ground level, provided they are collectively no more than 25 percent of the frontage. 3. The facade of the parking structure shall be integrally designed with the architecture of the overall building, utilize the same building materials, provide an architectural treatment at the top of the structure, such as a cornice, and have wall openings with proportions that comply with the fenestration requirements in Section 1246.04. 4. New parking structures shall be designed with an upper story minimum clear height of nine feet. 5. Parking facilities shall conform with Chapter 1252. Place of assembly | C | C | Permitted on non-local streets. Restaurant, bar, tavern | C | C | Permitted on non-local streets. Studio (dance, health, music, etc.) | P | P Drive-through, as accessory use | C | C | 1. A drive-through business may have a front setback greater than the build-to line required in the zoning district only to accommodate a travel lane for safe and efficient interior circulation. 2. No parking is allowed in the front yard. 3. The drive-through window shall be on the side or rear of the building. 4. Methods to minimize the impact of noise from outdoor speakers on adjacent residential are required. 5. The site must be adjacent to a suburban corridor, arterial corridor, prime connector, or activity corridor and all points of ingress and egress will be directly onto said street type. 6. Adequate waiting or standing areas for vehicles shall be provided on-site so that no vehicle is required to wait, stand, or be stored within a right-of-way, in accordance with the parking requirements of Chapter 1254. Accessory Uses Solar energy systems | P | P Solar energy systems storage | P | P Urban agriculture | P | P (a) Accessory uses customarily incidental to any of the above principal uses are allowed provided the Zoning Administrator may require additional parking or compliance with other standards upon a determination that such use may impact site operations beyond that of the principal use. (b) All activities shall take place within a completely enclosed building unless otherwise indicated. (c) All accessory materials shall be enclosed by a structure or a fence, which does not obstruct vision. (d) All materials stored within 30 feet of a fence shall not exceed the height of the fence. (e) Noise, odors, smoke, fumes, or dust generated on the site by any digging, excavating, manufacturing, loading or processing operation must be confined to the site and controlled to prevent any nuisance or hazard.
(Ord. No. 1331, § 1, 5-5-25)
Ask a question about Lansing law
Corpus searches the Lansing sections it holds and shows the ones that match, with their citations. Free, no sign-in.
